Abstract
Background
Gaining access into non-dilated renal collecting systems for percutaneous nephrolithotripsy, particularly in patients with prohibitive body habitus and/or scoliosis, is often challenging using conventional techniques.
Objective
To evaluate the feasibility of cone-beam CT for percutaneous nephrostomy placement for subsequent percutaneous nephrolithotripsy in children and adolescents.
Materials and methods
A retrospective review of percutaneous nephrostomy revealed use of cone-beam CT and 3-D guidance in 12 percutaneous nephrostomy procedures for 9 patients between 2006 and 2015. All cone-beam CT-guided percutaneous nephrostomies were for pre-lithotripsy access and all 12 were placed in non-dilated collecting systems.
Results
Technical success was 100%. There were no complications.
Conclusion
Cone-beam CT with 3-D guidance is a technically feasible technique for percutaneous nephrostomy in children and adolescents, specifically for nephrolithotripsy access in non-dilated collecting systems.
Similar content being viewed by others
References
Hogan MJ, Coley BD, Jayanthi VR et al (2001) Percutaneous nephrostomy in children and adolescents: outpatient management. Radiology 218:207–210
Yavascan O, Aksu N, Erdogan H et al (2005) Percutaneous nephrostomy in children: diagnostic and therapeutic importance. Pediatr Nephrol 20:768–772
Montvilas P, Solvig J, Johansen TEB (2011) Single-centre review of radiologically guided percutaneous nephrostomy using “mixed” technique: success and complication rates. Eur J Radiol 80:553–558
Toporek G, Wallach D, Weber S et al (2013) Cone-beam computed tomography-guided stereotactic liver punctures: a phantom study. Cardiovasc Intervent Radiol 36:1629–1637
Angle JF (2013) Cone-beam CT: vascular applications. Tech Vasc Interv Radiol 16:144–149
Racadio JM, Babic D, Homan R et al (2007) Live 3D guidance in the interventional radiology suite. AJR Am J Roentgenol 189:W357–W364
Busser WMH, Braak SJ, Futterer JJ et al (2013) Cone-beam CT guidance provides superior accuracy for complex needle paths compared with CT guidance. Br J Radiol 86:20130310
Ramchandani P, Cardella JF, Grassi CJ et al (2001) Quality improvement guidelines for percutaneous nephrostomy. J Vasc Interv Radiol 12:1247–1251
Yagci C, Ustuner E, Atman ED et al (2013) Diuretic agent and normal saline infusion technique for ultrasound-guided percutaneous nephrostomies in nondilated pelvicaliceal systems. Cardiovasc Intervent Radiol 36:492–497
Sommer CM, Huber J, Radeleff BA et al (2011) Combined CT-and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures. Eur J Radiol 80:686–691
Kogut M, Kooy TL, Oglevie SB (2012) Urologic and genital systems. In: Valji K (ed) The practice of interventional radiology. Elsevier, Pennsylvania, pp 684–717
Braak SJ, van Strijen MJL, van Es HW et al (2011) Effective dose during needle interventions: cone-beam CT guidance compared with conventional CT guidance. J Vasc Interv Radiol 22:455–461
Racadio JM, Yoshizumi TT, Toncheva G et al (2008) Radiation dosimetry evaluation of C-arm cone-beam CT for pediatric interventional radiology procedures: a comparison with MDCT. Presented at the Radiological Society of North America Annual Scientific Meeting, Chicago
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflicts of interest
The authors report no conflicts of interest.
Rights and permissions
About this article
Cite this article
Hawkins, C.M., Kukreja, K., Singewald, T. et al. Use of cone-beam CT and live 3-D needle guidance to facilitate percutaneous nephrostomy and nephrolithotripsy access in children and adolescents. Pediatr Radiol 46, 570–574 (2016). https://doi.org/10.1007/s00247-015-3499-1
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00247-015-3499-1