Abstract
To assess the feasibility and outcome of stent strut dilation after arterial duct stenting with associated branch pulmonary artery (BPA) stenosis. Stenting of arterial duct in infants with duct-dependent pulmonary circulation is technically challenging. The presence of BPA stenosis is a relative contraindication for stent implantation. Infants with duct-dependent pulmonary circulation and associated BPA stenosis were assessed either by transthoracic echocardiogram alone or additional computerized tomography angiogram when required. Following ductal stenting, the stent struts of the stenosed BPA were crossed with an additional 0.014″ coronary guide wire and dilated using coronary balloons (2.0 or 2.5 mm in diameter). Seventeen (12 male) patients were considered for the procedure. The median age and weight were 27 days (range 2–94) and 2.6 kg (range 2.2–5), respectively. Fourteen patients (82.4%) underwent stent strut dilation after arterial duct stenting. Struts to left pulmonary artery was opened in 9 (64.3%) and right pulmonary artery in 5 (35.7%). The mean systemic oxygen saturation increased from 66.23 ± 8.9% at baseline to 86 ± 2.2% immediately after the stent deployment and final saturations after stent strut dilation were 89.29 ± 4.3%. Angiographic pulmonary flow improved in all cases. Stent strut dilation could not be done in 3 patients due to unfavorable anatomy. One patient had acute stent thrombosis and died in the hospital. Two others died during follow-up, during an acute febrile illness and gastroenteritis. All survivors underwent cardiac surgery and were on regular follow-up. Strut dilation of BPA stenosis is feasible to augment pulmonary blood flow, following arterial duct stenting. This procedure may be useful in selected patients with BPA stenosis to have uniform growth of pulmonary arteries.
Similar content being viewed by others
References
Abrams SE, Walsh KP (1993) Arterial duct morphology with reference to angioplasty and stenting. Int J Cardiol 40:27–33
Elzenga NJ, Gittenberger-De Groot AC (1986) The ductus arteriosus and stenoses of the pulmonary arteries in pulmonary atresia. Int J Cardiol 11:195–208
Waldman JD, Karp RB, Gittenberger-De Groot AC, Agarwala B, Glagov S (1996) Spontaneous acquisition of discontinuous pulmonary arteries. Ann Thorac Surg 62:161–168
Nasser BA, Abdulrahman M, Qwaee AAL, Alakfash A, Mohamad T, Kabbani MS (2020) Impact of stent of ductus arteriosus and modified Blalock-Taussig shunt on pulmonary arteries growth and second-stage surgery in infants with ductus-dependent pulmonary circulation. J Saudi Heart Assoc 32(1):86–92
Bentham JR, Zava NK, Harrison WJ, Shauq A, Kalantre A, Derrick G, Chen RH, Dhillon R, Taliotis D, Kang SL, Crossland D, Adesokan A, Hermuzi A, Kudumula V, Yong S, Noonan P, Hayes N, Stumper O, Thomson JDR (2018) Duct stenting versus modified Blalock-Taussig shunt in neonates with duct-dependent pulmonary blood flow: associations with clinical outcomes in a multicenter national study. Circulation 137:581–588
Glatz AC, Petit CJ, Goldstein BH, Kelleman MS, McCracken CE, McDonnell A, Buckey T, Mascio CE, Shashidharan S, Ligon RA, Ao J, Whiteside W, Wallen WJ, Metcalf CM, Aggarwal V, Agrawal H, Qureshi AM (2018) Comparison between patent ductus arteriosus stent and modified Blalock-Taussig shunt as palliation for infants with ductal-dependent pulmonary blood flow: insights from the Congenital Catheterization Research Collaborative. Circulation 137:589–601
Alwi M, Choo KK, Latiff HA, Kandavello G, Samion H, Mulyadi MD (2004) Initial results and medium-term follow-up of stent implantation of patent ductus arteriosus in duct-dependent pulmonary circulation. J Am Coll Cardiol 44:438–445
Qureshi AM, Goldstein BH, Glatz AC, Agrawal H, Aggarwal V, Ligon RA, McCracken C, McDonnell A, Buckey TM, Whiteside W, Metcalf CM, Petit CJ (2019) Classification scheme for ductal morphology in cyanotic patients with ductal dependent pulmonary blood flow and association with outcomes of patent ductus arteriosus stenting. Catheter Cardiovasc Interv 93:933–943
Foin N, Torii R, Mortier P, De Beule M, Viceconte N, Chan PH, Davies JE, Xu XY, Krams R, Di Mario C (2012) Kissing balloon or sequential dilation of the side branch and main vessel for provisional stenting of bifurcations: lessons from micro-computed tomography and computational simulations. JACC Cardiovasc Interv 5:47–56
Pettersen MD, Du W, Skeens ME, Humes RA (2008) Regression equations for calculation of Z scores of cardiac structures in a large cohort of healthy infants, children, and adolescents: an echocardiographic study. J Am Soc Echocardiogr 21:922–934
Udink Ten Cate FE, Sreeram N, Hamza H, Agha H, Rosenthal E, Qureshi SA (2013) Stenting the arterial duct in neonates and infants with congenital heart disease and duct-dependent pulmonary blood flow: a multicenter experience of an evolving therapy over 18 years. Catheter Cardiovasc Interv 82:E233–E243
Ratnayaka K, Nageotte SJ, Moore JW, Guyon PW, Bhandari K, Weber RL, Lee JW, You H, Griffin DA, Rao RP, Nigro JJ, El-Said HG (2021) Patent ductus arteriosus stenting for all ductal-dependent cyanotic infants: waning use of Blalock-Taussig shunts. Circ Cardiovasc Interv 14(3):e009520. https://doi.org/10.1161/CIRCINTERVENTIONS.120.009520. (PMID: 33685211)
Santoro G, Capozzi G, Caianiello G, Palladino MT, Marrone C, Farina G, Russo MG, Calabrò R (2009) Pulmonary artery growth after palliation of congenital heart disease with duct-dependent pulmonary circulation: arterial duct stenting versus surgical shunt. J Am Coll Cardiol 54(23):2180–2186. https://doi.org/10.1016/j.jacc.2009.07.043. (PMID: 19942090)
Youssef AA, Hussein H, Hsueh SK, Chen CJ, Yang CH, Hang CL, Hsieh YK, Fang CY, Yip HK, Wu CJ (2010) Cobalt chromium coronary stents and drug-eluting stents in real practice. Int Heart J 51(4):231–237. https://doi.org/10.1536/ihj.51.231. (PMID: 20716838)
Author information
Authors and Affiliations
Contributions
All the authors of the study contributed in collecting the data, analysis, preparation of the manuscript and figures. All the authors reviewed the manuscript.
Corresponding author
Ethics declarations
Conflict of interest
The authors declare no competing interests.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Koneti, N.R., Bakhru, S., Dhulipudi, B. et al. Stent Strut Dilation in Branch Pulmonary Artery Stenosis Following Stenting of Arterial Duct in Duct-dependent Pulmonary Circulation. Pediatr Cardiol (2023). https://doi.org/10.1007/s00246-023-03319-2
Received:
Accepted:
Published: