Abstract
In order to solve the starting failure problem of surface-mounted permanent magnet synchronous motor (SPMSM) at zero speed, it is necessary to estimate the initial position of rotor by using the magnetic saturation effect of motor. In this paper, a new method of voltage vector injection is proposed to estimate the initial position of rotor. First of all, the voltage vector is injected into the A, B, and C phase axes of the motor stator, respectively. Then, the arcsine function of the virtual q-axis response current corresponding to the three injection voltage vectors is solved out, and the average value of calculation results will be equal to the estimated initial position angle of the rotor, which is expressed as Δθ. Finally, two voltage vectors are injected into the two estimated rotor position angles (Δθ and Δθ + π), respectively, and the polarity of the rotor N-pole will be determined by comparing the virtual d-axis response currents at the initial position. At the end of this paper, the proposed method is verified by experimental test, and the average error of estimated electrical angle is about 0.1845o. As this method has the advantages of not requiring a low-pass filter, reducing system complexity, and quickly estimating the initial rotor position, it has a great application prospect in the initial position estimation of PMSM sensorless control.
Similar content being viewed by others
References
Kuo CFJ, Hsu CH, Tsai CC (2007) Control of a permanent magnet synchronous motor with a fuzzy sliding-mode controller. Int J Adv Manuf Technol 32(7–8):757–763
Mesloub H, Benchouia MT, Goléa A, Goléa N, Benbouzid MEH (2016) Predictive dtc schemes with pi regulator and particle swarm optimization for pmsm drive: comparative simulation and experimental study. Int J Adv Manuf Technol 86(9–12):3123–3134
Jilong L, Fei X, Yang S et al (2017) Position-sensorless control technology of permanent-magnet synchronous motor-a review[J]. Transactions of China Electrotechnical Society 32:76–88
Smidl V, Peroutka Z (2012) Advantages of square-root extended Kalman filter for sensorless control of AC drives[J]. IEEE Trans Ind Electron 59(11):4189–4196
Mwasilu F, Jung JW (2016) Enhanced fault-tolerant control of interior PMSMs based on an adaptive EKF for EV traction applications[J]. IEEE Trans Power Electron 31(8):5746–5758
Shi Y (2012) Online identification of permanent magnet flux based on extended Kalman filter for IPMSM drive with position sensorless control[J]. IEEE Trans Ind Electron 59(11):4169–4178
Liu X, Zhang G, Mei L, Wang D (2016) Backstepping control with speed estimation of PMSM based on MRAS[J]. Autom Control Comput Sci 50(2):116–123
Khlaief A, Boussak M, Chaari A (2014) A MRAS-based stator resistance and speed estimation for sensorless vector controlled IPMSM drive[J]. Electr Power Syst Res 108:1–15
Lee D-M (2017) On-line parameter identification of SPM motors based on MRAS technique[J]. Int J Electron 104(4):593–607
Liang D, Li J, Qu R (2017) Sensorless control of permanent magnet synchronous machine based on second-order sliding-mode observer with online resistance estimation[J]. IEEE Trans Ind Appl 53(4):3672–3682
Saadaoui O, Khlaief A, Abassi M, Chaari A, Boussak M (2017) A sliding-mode observer for high-performance sensorless control of PMSM with initial rotor position detection[J]. Int J Control 90(2):377–392
Luo X, Tang Q, Shen A, Zhang Q (2016) PMSM Sensorless control by injecting HF pulsating carrier signal into estimated fixed-frequency rotating reference frame[J]. IEEE Trans Ind Electron 63(4):2294–2303
Tang QP, Shen A, Luo X et al (2018) IPMSM sensorless control by injecting bi-directional rotating HF carrier signals[J]. IEEE Trans Power Electron 33(12):10698–10707
Tang Q, Shen A, Luo X, Xu J (2017) PMSM sensorless control by injecting HF pulsating carrier signal into ABC frame[J]. IEEE Trans Power Electron 32(5):3767–3776
Xu PL, Zhu ZQ (2016) Novel carrier signal injection method using zero-sequence voltage for sensorless control of PMSM drives[J]. IEEE Trans Ind Electron 63(4):2053–2061
Xu PL, Zhu ZQ (2016) Novel square-wave signal injection method using zero-sequence voltage for sensorless control of PMSM drives[J]. IEEE Trans Ind Electron 63(12):7444–7454
Zhang X, Li H, Yang S, Ma M (2018) Improved initial rotor position estimation for PMSM drives based on HF pulsating voltage signal injection[J]. IEEE Trans Ind Electron 65(6):4702–4713
Wu X, Huang S, Liu X et al (2017) Design of position estimation strategy of sensorless interior PMSM at standstill using minimum voltage vector injection method[J]. IEEE Trans Magn 53(11):1–4
Xie G, Lu K, Dwivedi SK, Rosholm JR, Blaabjerg F (2016) Minimum-voltage vector injection method for sensorless control of PMSM for low-speed operations[J]. IEEE Trans Power Electron 31(2):1785–1794
Mamo M, Ide K, Sawamura M, Oyama J (2005) Novel rotor position extraction based on carrier frequency component method (CFCM) using two reference frames for IPM drives[J]. IEEE Trans Ind Electron 52(2):508–514
Xie M, Shakoor A, Shen Y, Mills JK, Sun D (2018) Out-of-plane rotation control of biological cells with a robot-tweezers manipulation system for orientation-based cell surgery. IEEE Trans Biomed Eng 66(1):199–207
Xie M, Li X, Wang Y, Liu Y, Sun D (2018) Saturated PID control for the optical manipulation of biological cells. IEEE Trans Control Syst Technol 26(5):1909–1916
Wu Z, Karimi HR, Dang C (2019) An approximation algorithm for graph partitioning via deterministic annealing neural network. Neural Netw 117:191–200
Bangcheng H, Yangyang S, Xinda S et al (2018) Initial rotor position detection method of SPMSM based on new high frequency voltage injection method[J]. IEEE Trans Power Electron (99):1–1
Chen Z, Gao J, Wang F, Ma Z, Zhang Z, Kennel R (2014) Sensorless control for SPMSM with concentrated windings using multisignal injection method[J]. IEEE Trans Ind Electron 61(12):6624–6634
Almarhoon AH, Zhu ZQ, Xu PL (2017) Improved pulsating signal injection using zero-sequence carrier voltage for sensorless control of dual three-phase pmsm[J]. IEEE Trans Energy Convers 32(2):436–446
Funding
This research has been supported by the National Natural Science Foundation of China (61803235), China Postdoctoral Science Foundation (2015 M582112), and key research and development project of Shandong province (2017GGX203005).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Ding, H., Fu, H., Fan, Y. et al. Initial rotor position estimation of SPMSM based on voltage vector injection method. Int J Adv Manuf Technol 105, 4929–4939 (2019). https://doi.org/10.1007/s00170-019-04201-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00170-019-04201-3