Skip to main content
Log in

An experimental comparison of PWM schemes to improve positioning of servo pneumatic systems

  • ORIGINAL ARTICLE
  • Published:
The International Journal of Advanced Manufacturing Technology Aims and scope Submit manuscript

Abstract

Distinct advantages of the combination of the pneumatic actuated plants with “on/off” solenoid valves have motivated many researchers to conduct research in this scope. Pulse-width modulation (PWM) is a tool to use such combination in servo tasks. This paper studies the most frequent and well-reported PWM schemes. These PWM schemes have been applied for positioning tasks of the pneumatic actuators using solenoid on/off valves. In this study, the positioning performance of the servo pneumatic system, utilizing different PWM schemes, is investigated through several experiments with step and sinusoidal reference inputs. Rise time, overshoot, and steady-state error, in step input tests, and tracking performance in sinusoidal tests demonstrate the effectiveness of the deployed PWM schemes in the pneumatic system behaviors. Moreover, the closed-loop results demonstrate that the system robustness against the increase of the system’s mass is associated with the applied PWM scheme. Based on the open-loop results, two factors are found to be affecting PWM schemes performance, namely, the difference in the cross-sectional areas on each side of the piston and the piston position, in which these factors have not been considered in the design procedure of the former studies. Taking into account the former factor, a modified version of the PWM schemes is proposed. Steady-state errors in closed-loop tests verify the effectiveness of the developed modified PWM schemes.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Anderson BW (1967) Analysis and design of pneumatic systems. John Wiley and Sons, New York

    Google Scholar 

  2. Shih M, Ma M (1998) Position control of a pneumatic cylinder using fuzzy PWM control method. Mechatronics 8:241–253

    Article  Google Scholar 

  3. van Varseveld RB, Bone GM (1997) Accurate position control of a pneumatic actuator using on/off solenoid valves. IEEE/ASME Trans Mechatron 2(3):195–204

    Article  Google Scholar 

  4. Bobrow JE, Jabbari F (1991) Adaptive pneumatic force actuation and position control. ASME J Dyn Syst Meas Control 113(June):267–272

    Article  Google Scholar 

  5. McDonell BW, Bobrow JE (1993) Adaptive tracking control of an air powered robot actuator. ASME J Dyn Syst Meas Control 115:427–433

    Article  MATH  Google Scholar 

  6. Surgenor BW, Vaughan ND (1997) Continuous sliding mode control of a pneumatic actuator. ASME J Dyn Syst Meas Control 119:578–581

    Article  MATH  Google Scholar 

  7. Richer E, Hurmuzlu Y (2000) A high performance pneumatic force actuator system: part II—nonlinear controller design. ASME J Dynam Syst Meas Control 122:426–434

    Article  Google Scholar 

  8. Refaat S, Nahavandi S (2006) Nonlinear identification of pneumatic servo-drive. Int J Model Simul 26(1):11–16

    Google Scholar 

  9. Wang J, Wang DJD, Moore PR, Pu J (2001) Modelling study, analysis and robust servocontrol of pneumatic cylinder actuator systems. IEE Proc Control Theory Appl 148:35–42

    Article  Google Scholar 

  10. Gao X, Feng ZJ (2005) Design study of an adaptive Fuzzy-PD controller for pneumatic servo system. J Control Eng Pract 13(1):55–65

    Article  Google Scholar 

  11. Noritsugu T (1987) Development of PWM mode electro-pneumatic servo mechanism, part II: position control of a pneumatic cylinder. J Fluid Control 17(2):7–28

    Google Scholar 

  12. Sorli M, Pastorelli S (2000) Performance of a pneumatic force controlling servosystem: influence of valves conductance. J Robot Auton Syst 30:283–300

    Article  Google Scholar 

  13. Linnett JA, Smith MC (1989) An accurate low-friction pneumatic position control system. Proc Inst Mech Eng B 203(33):159–165

    Article  Google Scholar 

  14. Gentile A, Giannoccaro NI, Reina G (2002) Experimental tests on position control of a pneumatic actuator using on/off solenoid valves. In: Proceedings of Industrial Technology, 2002. IEEE ICIT '02. 2002 IEEE International Conference, IEEE 1:555–559. doi:10.1109/ICIT.2002.1189959

  15. Paul AK, Mishra JK, Radke MG (1994) Reduce order sliding mode control for pneumatic actuator. IEEE Trans Control Syst Technol 2(3):271–276

    Article  Google Scholar 

  16. Barth EJ, Zhang J, Goldfarb M (2002) Sliding mode approach to PWM-controlled pneumatic systems. In: Proceedings of the 2002. IEEE, American Control Conference, 3:2362–2367. doi:10.1109/ACC.2002.1023995

  17. Shen X, Barth JE, Zhang J, Goldfarb M (2004) Nonlinear averaging applied to the control of pulse width modulated (PWM) pneumatic systems. In: Proceedings of the American Control Conference, IEEE Boston, MA, 5:4444–4448

  18. Najafi F, Fathi M, Saadat M (2009) Performance improvement of a PWM-sliding mode position controller used in pneumatic actuation. Int J Autom Soft Comput 15(1):73–84

    Article  Google Scholar 

  19. Ahn K, Yokota S (2005) Intelligent switching control of pneumatic actuator using on/off solenoid valves. Mechatronics 15:683–702

    Article  Google Scholar 

  20. Shen X, Goldfarb M (2007) Simultaneous force and stiffness control of a pneumatic actuator. ASME J Dyn Syst Meas Control 129(4):425–434

    Article  Google Scholar 

  21. Streeter VL, Victor L, Keith WB (1998) Fluid mechanics, 9th edn. WCB/McGraw-Hill, Boston

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Mohsen Shiee.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Shiee, M., Sharifi K., A., Fathi, M. et al. An experimental comparison of PWM schemes to improve positioning of servo pneumatic systems. Int J Adv Manuf Technol 82, 1765–1779 (2016). https://doi.org/10.1007/s00170-015-7501-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00170-015-7501-8

Keywords

Navigation