Abstract
During the actual operation of metro locomotives, some traction current leaks and injects into the ground, forming stray currents, resulting in surface potential differences along the line and causing DC bias of the main transformer in the urban area. Reasonably evaluating the degree of influence of transformer DC bias can effectively guide the suppression of transformer DC bias. In response to the above issues, this article first established a coupling model between stray current and DC bias of the main transformer in urban substations, and further modelled the distribution of transition resistance during subway operation, which achieved dynamic calculation of stray current; By selecting indicators such as neutral point DC, excitation current DC component, and harmonic distortion deviation, effective evaluation of the degree of DC bias influence on the main transformer along the subway line was achieved. The simulation results show that as the ground potential difference increases, the DC flow at the neutral point of the transformer increases. Along with the degree of hysteresis loop distortion in the iron core increases, the DC component of the excitation current and the deviation of harmonic distortion rate gradually increase. It is show that DC bias of the transformer becomes more severe.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Ogunsola, A., Sandrolini, L., Mariscotti, A.: Evaluation of stray current from A DC-electrified railway with Integrated electric–electromechanical modeling and traffic simulation. IEEE Trans. Ind. Appl. 51(6), 5431–5441(2015)
Li, X., Chu, F., Shi, S.: Influence of rail transit on neutral current and vibration of 220 kV substation along the line. Trans. China Electrotech. Soc. 36(S2), 423–429+437 (2021) (in Chinese)
Lin, S., Huangfu, Y., Zhou, Q., et al.: Evaluation and analysis model of stray current in the metro depot. IEEE Trans. Transp. Electrification 7(7), 1780–1794 (2021)
Li, H., Cui, X., Lu, T., et al.: Electric circuit and magnetic circuit combined model of DC biased power transformer. Proc. CSEE 29(27), 119–125 (2009). (in Chinese)
Wang, Z., Li, M., Xuan, M., et al.: Temperature Rise Test and Simulation of Single-phase Four-column Transformer under DC-bias. Trans. China Electrotech. Soc. 36(05), 1006–1013 (2021). (in Chinese)
Zhang, S., Wang, K., Li, J, et al.: Tests of DC bias key performances of power transformer with single-phase three-limb core under no-load and rated-load conditions. Proc. CSEE 39(14), 4334–4344+4281(2019) (in Chinese)
Chen, J., Wang, D., Cheng, S., et al.: Influence of DC-biased magnetic induction on magnetic property of silicon steel. IEEE Trans. Magn. 55(5) (2019)
Wang, A., Lin, S., Hu, Z., et al.: Evaluation model of DC current distribution in AC power systems caused by stray current of DC metro systems. IEEE Trans. Power Deliv. 36(1), 114–123 (2021)
Shi, Y., Zhao, L., Lin, S., et al.: Analysis of distribution of metro stray current in urban power grid and its influencing factor. Power Syst. Technol. 45(05), 1951–1957 (2021). (in Chinese)
Wu, G., Xiao, L., Zhang, F., et al.: Simulation analysis of distribution characteristics of urban rail transit stray current in power system. South. Power Syst. Technol. 13(10), 39–43+61 (2019) (in Chinese)
Liu, W., Zhou, L., Tang, Y., et al.: Co-simulated model of DC traction power supply return system and stray current diffusion. Trans. China Electrotech. Soc., 1–11(2023) (in Chinese)
Ma, S., Rong, Z., Lin, X., et al.: Study on the global optimal configuration of DC bias equipment considering the cooperation of multiple devices. Proc. CSEE 11(06), 85–91 (2014). (in Chinese)
Ni, Y., Zeng, X., Yu, K., et al.: Modeling and influencing factors analysis of dynamic potential distribution caused by metro stray current. Proc. CSEE, 1–14 (2022) (in Chinese)
Acknowledgments
This research was supported by the Science and Technology Project of the State Grid Corporation of China: Research on the coupling influence and suppression method of grid DC bias caused by metro stray current (5100-202199276A-0-0-00).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2024 Beijing Paike Culture Commu. Co., Ltd.
About this paper
Cite this paper
Xinxiang, C., Kun, Y., Yanru, N., Yuhang, T., Xiangjun, Z., Wei, H. (2024). Research on the Evaluation Model of Urban Main Transformer DC Bias Caused by Metro Stray Current. In: Qin, Y., Jia, L., Yang, J., Diao, L., Yao, D., An, M. (eds) Proceedings of the 6th International Conference on Electrical Engineering and Information Technologies for Rail Transportation (EITRT) 2023. EITRT 2023. Lecture Notes in Electrical Engineering, vol 1137. Springer, Singapore. https://doi.org/10.1007/978-981-99-9311-6_26
Download citation
DOI: https://doi.org/10.1007/978-981-99-9311-6_26
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-99-9310-9
Online ISBN: 978-981-99-9311-6
eBook Packages: EngineeringEngineering (R0)