Analysis of Air Side Cooling and Dehumidification Performance in Evaporator in Direct Expansion (DX) Variable Refrigerant Flow (VRF) Air-Conditioning (A/C) System

  • Chapter
  • First Online:
Variable Refrigerant Flow Systems
  • 270 Accesses

Abstract

Direct Expansion Variable Refrigerant Flow Air-Conditioning (DX-VRF-A/C) units can be seen in buildings of all sizes. The evaporator in a DX-VRF-A/C unit (or DX air cooling coil), normally generates heat and mass transfer in the form of cooling and dehumidifying of hot and humid air flowing through the cooling coil. DX air-conditioning unit with single speed compressors and forced draft fans usually rely on switch control to maintain only the indoor dry bulb temperature which results in an uncontrolled balance of indoor humidity and reduces thermal comfort, and consequently causes poor indoor air quality (IAQ) as well as produces low energy efficiency. Thus, DX air-conditioning unit with variable-speed compressors and forced draft fans are increasingly adopted in pursuit of higher energy efficiency and thermal comfort indoor environment. Hence, study the simultaneous heat and mass transfer performance in DX air cooling coil of DX air-conditioning unit with variable-speed compressor and forced draft fan is essential, however, research work is still lacking in regards to this A/C system. A comprehensive analysis of the airside cooling and dehumidification process in DX cooling coil and its application are illustrated in this chapter. It commences with introducing the calculation of an important dimensionless parameter, namely steady state Equipment Sensible Heat Ratio (SHR) of DX air cooling coil, which is defined as the ratio of the output sensible cooling capacity of DX cooling coil to the total output cooling capacity. An experimental study on estimating on the dehumidification effect on the airside of the superheated region (SPR) in a DX cooling coil is given. The development of the modified Logarithmic Mean Enthalpy Difference (LMED) method for evaluating the total heat transfer rate in a wet air cooling coil operating under both unit and non-unit Lewis Factors (Le2/3) conditions is reported at the end of this chapter.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 139.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 179.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 179.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Edward GP (1989) Air conditioning principles and systems: an energy approach, second edn.

    Google Scholar 

  2. Lam JC (1996) An analysis of residential sector energy use in Hong Kong. Energy 21(1):1–8

    Article  Google Scholar 

  3. Lam JC (2000) Residential sector air conditioning loads and electricity use in Hong Kong. Energy Convers Manage 41:1757–1768

    Article  Google Scholar 

  4. Brandemuehl MJ, Katejanekarn T (2004) Dehumidification characteristics of commercial building applications. ASHRAE Trans 114(2):65–76

    Google Scholar 

  5. Fanger PO (2001) Human requirements in future air-conditioned environments. Int J Refrig 24(2):148–153

    Article  Google Scholar 

  6. Arens EA, Baughman AV (1996) Indoor humidity and human health: part II-buildings and their systems. ASHRAE Trans 102(1):212–221

    Google Scholar 

  7. Toftum J, Fanger PO (1999) Air humidity requirements for human comfort. ASHRAE Trans 105(2):641–647

    Google Scholar 

  8. Sterling EM, Arundel A, Sterling TD (1985) Criteria for human exposure to humidity in occupied buildings. ASHRAE Trans 91(1B):611–622

    Google Scholar 

  9. Green GH (1982) The positive and negative effects of building humidification. ASHRAE Trans 88(1):1049–1061

    Google Scholar 

  10. ASHRAE (2001) Handbook of fundamentals

    Google Scholar 

  11. Tanabe S, Kimura K, Hara T (1987) Thermal comfort requirements during the summer season in Japan. ASHRAE Trans 93(Pt. 1):564–577

    Google Scholar 

  12. Fountain ME, Arens E, Xu TF, Bauman FS, Oguru M (1999) An investigation of thermal comfort at high humidities. ASHRAE Trans 105(2):94–103

    Google Scholar 

  13. Olesen BW, Brager GS (2004) A better way to predict comfort. ASHRAE J 46(8):20–28

    Google Scholar 

  14. ASHRAE (2001) ANSI/ASHRAE standard 62–2001, ventilation for acceptable indoor air quality

    Google Scholar 

  15. ASHRAE (2000) Handbook-HVAC systems and equipment

    Google Scholar 

  16. Krakow KI, Lin S, Zeng ZS (1995) Temperature and humidity control during cooling and dehumidifying by compressor and evaporator fan speed variation. ASHRAE Trans 101(1):292–304

    Google Scholar 

  17. Andrade MA, Bullard CW, Hancock S, Lubliner M (2002) Modulating blower and compressor capacities for efficient comfort control. ASHRAE Trans 108(1):631–637

    Google Scholar 

  18. Li Z, Deng SM (2007) An experimental study on the inherent operational characteristics of a direct expansion (DX) air conditioning (A/C) unit. Build Environ 42(1):1–10

    Article  Google Scholar 

  19. Li Z, Deng SM (2007) A DDC-based capacity controller of a direct expansion (DX) air conditioning (A/C) unit for simultaneous indoor air temperature and humidity control Part I: Control algorithms and preliminary controllability tests. Int J Refrig 30:113–123

    Article  CAS  Google Scholar 

  20. Li Z, Deng SM (2007) A DDC-based capacity controller of a direct expansion (DX) air conditioning (A/C) unit for simultaneous indoor air temperature and humidity control Part II: Further development of the controller to improve control sensitivity. Int J Refrig 30:124–133

    Article  Google Scholar 

  21. Threlkeld JL (1970) Thermal environmental engineering

    Google Scholar 

  22. ASHRAE (2005) ASHRAE fundamentals, mass transfer

    Google Scholar 

  23. Elmahdy AH, Mitalas GP (1977) A simple model for cooling and dehumidifying coils for use in calculating energy requirements for buildings. ASHRAE Trans 83(2):103–117

    Google Scholar 

  24. Jacobi AM, Goldschmidt VW (1990) Low Reynolds number heat and mass transfer measurements of an overall counter-flow baffled finned-tube condensing heat exchanger. J Heat Transfer 33(4):755–765

    Article  Google Scholar 

  25. Jin GY, Cai WJ, Wang YW, Yao Y (2006) A simple dynamic model of cooling coil unit. Energy Convers Manage 47(15–16):2659–2672

    Article  Google Scholar 

  26. McQuiston FC, Parker JD (1994) Heating ventilating and air conditioning, fourth edn.

    Google Scholar 

  27. McQuiston FC (1978) Heat, mass and momentum transfer data for five plate-fin-tube heat transfer surfaces. ASHRAE Trans 84(1):266–293

    Google Scholar 

  28. Theerakulpisut S, Priprem S (1998) Modeling cooling coils. Int Commun Heat Mass Transfer 25(1):127–137

    Article  CAS  Google Scholar 

  29. Wang J, Hihara E (2003) Prediction of air coil performance under partially wet and totally wet cooling conditions using equivalent dry-bulb temperature method. Int J Refrig 26(3):293–301

    Article  Google Scholar 

  30. Huzzayyin AS, Nada SA, Elattar HF (2007) Air-side performance of wavy-finned-tube direct expansion cooling and dehumidifying air coil. Int J Refrig 30(2):230–244

    Article  Google Scholar 

  31. Xia Y, Jacobi AM (2005) Air-side data interpretation and performance analysis for heat exchangers with simultaneous heat and mass transfer: wet and frosted surfaces. Int J Heat Mass Transf 48(25–26):5089–5102

    Article  CAS  Google Scholar 

  32. Byun JS, Lee JH, Choi JY (2007) Numerical analysis of evaporation performance in a finned-tube heat exchanger. Int J Refrig 30(5):812–820

    Article  Google Scholar 

  33. Hill JM, Jeter SM (1991) A linear subgrid cooling and dehumidification coil model with emphasis on mass transfer. ASHRAE Trans 97(2):118–128

    Google Scholar 

  34. Jia X, Tso CP, Jolly P, Chia PK (1995) A distributed model for prediction of the transient response of an evaporator. Int J Refrig 18(5):336–342

    Article  CAS  Google Scholar 

  35. Jia X, Tso CP, Jolly P, Wong YW (1999) Distributed steady and dynamic modeling of dry-expansion evaporators. Int J Refrig 22(2):126–136

    Article  CAS  Google Scholar 

  36. Kabelac S (1989) The transient response relations for a serpentine cross-flow heat exchanger with water velocity disturbance. Int J Heat Mass Transf 32(6):1183–1189

    Article  CAS  Google Scholar 

  37. Liang SY, Wong TN, Nathan GK (2001) Numerical and experimental studies of refrigerant circuitry of evaporator coils. Int J Refrig 24(8):823–833

    Article  CAS  Google Scholar 

  38. Mirth DR, Ramadhyani S (1993) Prediction of cooling-coil performance under condensing conditions. Int J Heat Fluid Flow 14(4):391–400

    Article  CAS  Google Scholar 

  39. Myers GE, Mitchell JW, Linderman CF (1970) The transient response of heat exchanger having an infinite capacitance rate fluid. ASME J Heat Transfer 92(2) Series C:269–275

    Google Scholar 

  40. Ramachandran PV (1984) Simulation and optimization of cooling coils. PhD thesis, Department of Mechanical Engineering, Indian Institute of Technology

    Google Scholar 

  41. Vardhan A, Dhar PL (1998) A new procedure for performance prediction of air conditioning coils. Int J Refrig 21(1):77–83

    Article  Google Scholar 

  42. Yu X, Jin W, Smith TF (2005) A model for the dynamic response of a cooling coil. Energy Build 37(12):1278–1289

    Article  Google Scholar 

  43. Xia Y, Jacobi AM (2004) An exact solution to steady heat conduction in a two-dimensional slab on a one-dimensional fin: application to frosted heat exchangers. Int J Heat Mass Transf 47(14–16):3317–3326

    Article  Google Scholar 

  44. Bandyopadhyay G, Gosnold W, Mann M (2008) Analytical and semi-analytical solutions for short-time transient response of ground heat exchangers. Energy Build 40(10):1816–1824

    Article  Google Scholar 

  45. Bielski S, Malinowski L (2005) An analytical method for determining transient temperature field in a parallel-flow three-fluid heat exchanger. Int Commun Heat Mass Transfer 32(8):1034–1044

    Article  CAS  Google Scholar 

  46. Kabashnikov VP, Danilevskii LN, Nekrasov VP, Vityaz IP (2002) Analytical and numerical investigation of the characteristics of a soil heat exchanger for ventilation systems. Int J Heat Mass Transf 45(11):2407–2418

    Article  Google Scholar 

  47. Klein H, Eigenberger G (2001) Approximate solutions for metallic regenerative heat exchangers. Int J Heat Mass Transf 44(18):3553–3563

    Article  Google Scholar 

  48. Ren C, Yang H (2006) An analytical model for the heat and mass transfer processes in indirect evaporative cooling with parallel/counter flow configurations. Int J Heat Mass Transf 49(3–4):617–627

    CAS  Google Scholar 

  49. Amrane K, Hourahan GC, Potts G (2003) Latent performance of unitary equipment. ASHRAE J 45(1):28–31

    Google Scholar 

  50. Wang G, Liu MS, Claridge DE (2007) Decoupled modeling of chilled-water cooling coils. ASHRAE Trans 113(1):484–493

    Google Scholar 

  51. ASHRAE (1983) Handbook-HVAC systems and equipment

    Google Scholar 

  52. Stevens RA, Fernandez J, Woolf J (1957) Mean temperature difference in one- two- and three-pass crossflow heat exchangers. Trans ASME 79:287–297

    Google Scholar 

  53. Myers RJ (1967) The effect of dehumidification on the air-side heat transfer coefficient for a finned-tube coil. MS thesis, Department of Civil Engineering, University of Minnesota

    Google Scholar 

  54. Chen W, Deng S (2006) Development of a dynamic model for a DX VAV air conditioning system. Energy Convers Manage 47(18–19):2900–2924

    Article  Google Scholar 

  55. Deng SM (2000) A dynamic mathematical model of a direct expansion (DX) water-cooled air-conditioning plant. Build Environ 35(7):603–613

    Article  Google Scholar 

  56. Gungor KE, Winterton RHS (1987) Simplified general correlation for saturated flow boiling and comparisons of correlations with data. Can J Chem Eng Chem Eng Res Des 65:148–156

    CAS  Google Scholar 

  57. Kandlikar SG (1990) A general correlation for saturated two-phase flow boiling heat transfer inside horizontal and vertical tubes. ASME J Heat Transf 112(1):219–228

    Article  CAS  Google Scholar 

  58. Shah MM (1982) Chart correlation for saturated boiling heat transfer: equations and further study. ASHRAE Trans 88(1):185–196

    Google Scholar 

  59. Boissieux X, Heikal M, Johns R (2000) Two-phase heat transfer coefficients of three HFC refrigerants inside a horizontal smooth tube, part I: evaporation. Int J Refrig 23(4):269–283

    Article  CAS  Google Scholar 

  60. Turaga M, Lin S, Fazio PF (1988) Correlations for heat transfer and pressure drop factors for direct expansion air cooling and dehumidifying coils. ASHRAE Trans 94(2):616–629

    Google Scholar 

  61. Hong TK, Webb RL (1996) Calculation of fin efficiency for wet and dry fins. Int J HVAC&R Res 2(1):27–41

    Article  Google Scholar 

  62. McQuiston FC (1975) Fin efficiency with combined heat and mass transfer. ASHRAE Trans 81(1):350–355

    Google Scholar 

  63. Holman JP (1994) Experimental methods for engineers. McGraw-Hill, New York

    Google Scholar 

  64. Brodrick J, Gilbride T (2002) Focusing on buyers’ needs: DOE’s emerging technology program. Energy Eng 99(6):18–37

    Article  Google Scholar 

  65. Chi J, Didion D (1982) A simulation model of the transient performance of a heat pump. Int J Refrig 5(3):176–184

    Article  CAS  Google Scholar 

  66. MacArthur JW (1984) Transient heat pump behavior: a theoretical investigation. Int J Refrig 7(2):123–132

    Article  Google Scholar 

  67. Wang H, Touber S (1991) Distributed and non-steady-state modeling of an air cooler. Int J Refrig 14(2):98–111

    Article  Google Scholar 

  68. Fisher SK, Rice CK (1983) The oak ridge heat pump model: I. A steady-state computer design model for air-to-air heat pumps. ORNL/CON-80/R1, Energy Division, Oak Ridge National Lab

    Google Scholar 

  69. Mullen CE, Bridges BD, Porter KJ, Hahn GW, Bullard CW (1997) Development and validation of a room air-conditioning simulation model. ACRC TR-116

    Google Scholar 

  70. Qi Q, Deng SM (2008) Multivariable control-oriented modeling of a direct expansion (DX) air conditioning (A/C) system. Int J Refrig 31(5):841–849

    Article  CAS  Google Scholar 

  71. Dittus FW, Boelter LMK (1930) Heat transfer in automobile radiators of the turbulent type. Univ Calif Publ Eng 2:443–461

    Google Scholar 

  72. Eckels PW, Rabas TJ (1987) Dehumidification: on the correlation of wet and dry transport process in plate finned-tube heat exchangers. ASME J Heat Transfer 109:575–582

    Article  CAS  Google Scholar 

  73. Pirompugd W, Wang CC, Wongwises S (2007) Finite circular fin method for heat and mass transfer characteristics for plain-fin-and-tube heat exchangers under fully and partially wet surface conditions. Int J Heat Mass Transf 50(3–4):552–565

    Article  Google Scholar 

  74. Seshimo Y, Ogawa K, Marumoto K, Fujii M (1988) Heat and mass transfer performances on plate fin and tube heat exchangers with dehumidification. Trans JSME 54:716–721

    Article  CAS  Google Scholar 

  75. Moffat RJ (1988) Describing the uncertainties in experimental results. Exp Thermal Fluid Sci 1:2681–2691

    Article  Google Scholar 

  76. Wang CC (2008) On the heat and mass transfer analogy of fin-and-tube heat exchanger. Int J Heat Mass Transf 51:2055–2059

    Article  CAS  Google Scholar 

Download references

Acknowledgements

This research was funded by the Ningbo Natural Science Foundation Project, Project references: 2019A610094 and Beijing University of Technology, Project references: E01210300004. The research study was also supported by the Ningbo Science and Technology Bureau under Grant no: 2021S141.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Isaac Lun .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2023 The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Xia, L., Lun, I. (2023). Analysis of Air Side Cooling and Dehumidification Performance in Evaporator in Direct Expansion (DX) Variable Refrigerant Flow (VRF) Air-Conditioning (A/C) System. In: Enteria, N., Sawachi, T., Saito, K. (eds) Variable Refrigerant Flow Systems. Springer, Singapore. https://doi.org/10.1007/978-981-19-6833-4_4

Download citation

  • DOI: https://doi.org/10.1007/978-981-19-6833-4_4

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-19-6832-7

  • Online ISBN: 978-981-19-6833-4

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics