Abstract
This article presents the study on the behaviour of doubly built-up cold-formed beams under flexure. The built-up sections are made by connecting two channel sections back to back which are attached by welding. A series of experiment tests were carried out on beam specimens having with lip and without lip sections, each with 200 mm depth and 240 mm depth respectively. The adopted thickness of beam section is 1.6 mm and 2 mm. The parameters involved in this study are effective width to thickness ratio and sections with and without lip. All the beams failed at local buckling at top flange due to lateral instability of the cold-formed steel structural members and then followed by lateral torsional buckling. The theoretical calculations are made as per IS: 801-1975 code, which is based on the working stress method. The analytical investigation of the built-up section is also carried out using FEM modelling software. All the specimens indicate nearly closer values to each other in theoretical, analytical and experimental study. From this study, it is concluded that doubly symmetric built-up cold-formed sections are preferred for higher load carrying capacity with less complicated buckling modes.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Anbarasu M, Sukumar S (2014) Local/distortional/global buckling mode interaction on thin walled lipped channel. Latin Am J Solids Struct 11(8):1363–1375
Reza W, Senthil Selvan S. (2016) Experimental study on flexural behavior of cold formed steel channel and I sections providing angle stiffener on the web. Indian J Sci Technol 9(35):114–121
Karthikeyan KA, Jaisankar G (2016) Numerical and experimental investigation of buckling strength of cold formed steel built-up beams. Int J Eng Sci Comput 6(5):240–248
Mohammad S, Dar AR (2015) Flexural behavior of stiffened modified cold-formed steel sections-experimental study. Int J Civ Eng Technol 6(9):109–115
Wang L, Young B (2016) Behavior of cold-formed steel built-up sections with intermediate stiffeners under bending. J Struct Eng 142(3):110–124
Basaglia C, Camotim D (2013) Buckling, post buckling, strength and DSM design of cold-formed steel continuous lipped channel beams. J Struct Eng ASCE 132(4):515–524
IS 801-1975 (2010) Indian Standard Code of Practice for Use of Cold-formed Light Gauge Steel Structural Members in General Building Construction. Bureau of Indian Standards, New Delhi
“Ansys Software” (2017) Associated Press, California, May 16. Retrieved June 10 (2017)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2022 The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Gajalakshmi, P., Revathy, J., Anusha, S., Vijayan, D.S. (2022). Behaviour of Doubly Symmetric Built-Up Cold-Formed Steel Beams. In: Kolathayar, S., Ghosh, C., Adhikari, B.R., Pal, I., Mondal, A. (eds) Resilient Infrastructure . Lecture Notes in Civil Engineering, vol 202. Springer, Singapore. https://doi.org/10.1007/978-981-16-6978-1_18
Download citation
DOI: https://doi.org/10.1007/978-981-16-6978-1_18
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-16-6977-4
Online ISBN: 978-981-16-6978-1
eBook Packages: EngineeringEngineering (R0)