Skip to main content

A 1531.52 nm Tunable Diode Laser-Based System for High-Sensitivity Remote Monitoring of Acetylene and Ammonia Leaks in Industrial Plants

  • Conference paper
  • First Online:
ICOL-2019

Part of the book series: Springer Proceedings in Physics ((SPPHY,volume 258))

Abstract

We demonstrate a 1531.52 nm tunable diode laser -based sensor system that can be used to build a dense, wide-area sensor network for in situ multi-point detection of acetylene (C2H2) and ammonia (NH3) leaks in industrial safety applications. The detection limit of the sensor is 16 ppm for C2H2 and 228 ppm for NH3 using a 28 cm long single-pass gas cell. High temperature measurements are also demonstrated in a tube furnace using a 1392.54 nm laser-based sensor. The accuracy of temperature measurement is 92.13% at 500 K and 96.79% at 700 K.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 149.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 199.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. C.S. Goldenstein, C.L. Strand, I.A. Schultz, K. Sun, J.B. Jeffries, R.K. Hanson, Fitting of calibration-free scanned-wavelength-modulation spectroscopy spectra for determination of gas properties and absorption lineshapes. Appl. Opt. 53, 356–367 (2014)

    Article  ADS  Google Scholar 

  2. A. Upadhyay, A.L. Chakraborty, Calibration-free 2f WMS with in situ real-time laser characterization and 2f RAM nulling. Opt. Lett. 40, 4086–4089 (2015)

    Article  ADS  Google Scholar 

  3. S. Schilt, L. Thevenaz, P. Robert, Wavelength modulation spectroscopy: combined frequency and intensity laser modulation. Appl. Opt. 42, 6728–6738 (2003)

    Article  ADS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Anirban Roy .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2021 The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Roy, A., Chakraborty, A.L., Grattan, K.T.V. (2021). A 1531.52 nm Tunable Diode Laser-Based System for High-Sensitivity Remote Monitoring of Acetylene and Ammonia Leaks in Industrial Plants. In: Singh, K., Gupta, A.K., Khare, S., Dixit, N., Pant, K. (eds) ICOL-2019. Springer Proceedings in Physics, vol 258. Springer, Singapore. https://doi.org/10.1007/978-981-15-9259-1_86

Download citation

Publish with us

Policies and ethics