Abstract
Since 2000 when the My Thuan Bridge, the first cable-stayed bridge in Vietnam, was put into operation, and now Vietnam has more than 20 types of cable-stayed bridges. Therefore, the Structural health monitoring (SHM) system is gradually being designed and installed for cable stayed bridges to ensure eco-nomic exploitation and safety. Due to the limited of financing sources, these systems are very limited, and their quality have a lot to be desired. Also, due to the lack of appropriate classification personnel with experience in the SHM system, these systems encountered a lot of problems. In this article author will deeply analyze the mistakes and problems of these SHM systems to find solutions for the future.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
K. Matsuno & N. Taki, 2014 - Construction of the Nhat Tan (Japan Vietnam Friendship Bridge) Superstructure. Bridge and Foundation Engineering Vol. 48: 02–12.
L. M. Chinh, 2014. BRIMOS – SHM system for cable-stayed Can Tho Bridge, Inżynieria I Budownictwo – ISSN 0021-0315. Poland. No 7/2014:.397-400.
L. M. Chinh, 2014. Long term structural health monitoring system for cable stayed bridge in Vietnam. Tạp chí Khoa học kỹ thuật thủy lợi và Môi trường - ISSN: 1859-3941. No. 44 (3/2014)
L. M. Chinh, G. Swit, 2015. Application of the acoustic emission method of identification and location of destructive processes to the monitoring of the technical state of pre-stressed concrete bridges. Hội nghị khoa học Công nghệ Giao thông vận tải lần thứ III, năm 2015.
L. M. Chinh, G. Swit, A. Adamczak, A. Krampikowska. 2016. Nhat Tan Bridge – The biggest cable-stayed bridge in Vietnam. Symposium WMCAUS 2016. Czech. Procedia Engineering 161 (2016): 666 – 673.
L. M. Chinh. G. Swit. 2016. A Prototype System for Acoustic Emission-Based Structural Health Monitoring of Mỹ Thuận Bridge. Prognostics & System Health Management Conference—Chengdu (PHM-2016 Chengdu, China).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Chinh, L.M. (2020). The Inadequacies of the Existing Structural Health Monitoring Systems for Cable Stayed Bridges in Vietnam. In: Ha-Minh, C., Dao, D., Benboudjema, F., Derrible, S., Huynh, D., Tang, A. (eds) CIGOS 2019, Innovation for Sustainable Infrastructure. Lecture Notes in Civil Engineering, vol 54. Springer, Singapore. https://doi.org/10.1007/978-981-15-0802-8_31
Download citation
DOI: https://doi.org/10.1007/978-981-15-0802-8_31
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-15-0801-1
Online ISBN: 978-981-15-0802-8
eBook Packages: EngineeringEngineering (R0)