Abstract
Determining ventilation rates is helpful to study indoor air quality (IAQ). This paper investigated the natural ventilation of three households in Beijing, using exhaled CO2 as the tracer gas to calculate and determine the ventilation rates. Also it considered ventilation conditions in different seasons, in different outdoor air quality, and in different outdoor temperatures. The results show that there are seasonal differences in window opening behavior, and outdoor temperature has a more significant effect on window opening behavior than that outdoor air quality. The data obtained in this study and its analysis is thought useful as a reference source for other studies of energy-saving ventilation systems.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Dai, X., et al.: Long-term monitoring of indoor CO2 and PM2.5 in Chinese homes: concentrations and their relationships with outdoor environments. Build. Environ. 144, 238–247 (2018)
Lai, D., et al.: Ventilation behaviour in residential buildings with mechanical ventilation systems across different climate zones in China. Build. Environ. 143, 679–690 (2018)
Bornehag, C.G., et al.: Dampness in dwellings and sick building symptoms among adults a cross-sectional study on 8918 Swedish homes. In: Proceedings of 7th International Conference on Healthy Buildings, Singapore pp. 582–587 (2003)
Pinto, M., et al.: Air change rates in multi-family residential buildings in Northern Portugal. In: Proceedings of 7th International Conference on Healthy Buildings, Singapore, pp. 333–338 (2003)
Bekö, G., et al.: Ventilation rates in the bedrooms of 500 Danish children. Build. Environ. 45(10), 2289–2295 (2010)
Hou, J.: Study on Ventilation Rates in Residential Buildings and its Associations with Health. Doctoral dissertation, Tianjin University (2015)
Qi, M., et al.: Discussion on measuring ventilation rates of dorms through tracer gas method with human body as CO2 release source. Build. Sci. 29(6), 52–57 (2013)
Stavova, P., et al.: A new approach for ventilation measurement in homes based on CO2 produced by people-laboratory study. In: Proceedings of 17th Air-conditioning and Ventilation Conference, pp. 291–296 (2006)
Chinese National Standard, HJ 633-2012: Technical Regulation on Ambient Air Quality Index (on trial) (2012)
Acknowledgements
The research was supported financially by the National Project of the Ministry of Science and Technology, China, on Green Buildings and Building Industrialization under Grant No. 2016YFC0700501.
Ethical approval All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.
Informed consent Informed consent was obtained from all individual participants included in the study.
Permissions Appropriate permissions from house owners were obtained for study in natural ventilation of household.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Sun, R., Jian, Y., Wang, X. (2020). Field Monitoring of the Natural Ventilation Rate of Residential Buildings in Beijing. In: Wang, Z., Zhu, Y., Wang, F., Wang, P., Shen, C., Liu, J. (eds) Proceedings of the 11th International Symposium on Heating, Ventilation and Air Conditioning (ISHVAC 2019). ISHVAC 2019. Environmental Science and Engineering(). Springer, Singapore. https://doi.org/10.1007/978-981-13-9520-8_130
Download citation
DOI: https://doi.org/10.1007/978-981-13-9520-8_130
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-13-9519-2
Online ISBN: 978-981-13-9520-8
eBook Packages: Earth and Environmental ScienceEarth and Environmental Science (R0)