Abstract

Hemodynamic parameters play a very important role in supporting physicians to diagnose and treat cardiovascular diseases. This paper presents the results of the study on designing of noninvasive hemodynamic monitoring equipment using impedance cardiography (ICG). This is a measurement method that shows many advantages and is interested in the present. The equipment has ability of measurement and monitoring hemodynamic parameters include: heart rate HR; thoracic fluid content TFC; left ventricular ejection time LVET; stroke volume SV; cardiac output CO and ICG waveform. Results of measurement between the research equipment BK-NICO and the standard equipment of NICCOMO for 104 patients show that the hemodynamic parameters measured by the two equipments are quite small difference. Specifically, the average deviation of the parameters obtained, HR is 0.16 bpm, TFC is 0.73 1/kΩ, LVET is 5.95 ms, SV is 0.17 ml, CO is 0.01 lpm. With the results of the research, the device is fully capable of deploying the application into practice in the hospitals to replace the current invasive measurement method.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Cybulski, G.: Ambulatory Impedance Cardiography—The Systems and Their Applications. Springer, New York (2011)

    Book  Google Scholar 

  2. Cybulski, G., Strasz, A., Niewiadomski, W., Gasiorowska, A.: Impedance cardiography: recent advancements. Cardiol J 19(5), 550–556 (2012)

    Article  Google Scholar 

  3. Webster, J.G.: Medical Instrumentation: Application and Design: Measurement of Flow and Volume of Blood. Wiley, New York (2010)

    Google Scholar 

  4. Ipate, M.C., Dobre, A.A., Morega, A.M.: The stroke volume and the cardiac output by the impedance cardiography. U.P.B. Sci. Bull. 74(3) (2012)

    Google Scholar 

  5. Geerts, B.F., Aarts, L.P., Jansen, J.R.: Methods in pharmacology: measurement of cardiac output. Br. J. Clin. Pharmacol. 71(3), 316–330 (2011)

    Article  Google Scholar 

  6. Lavdaniti, M.: Invasive and non-invasive methods for cardic output measurement. Int. J. Caring Sci. 1(3), 112–117 (2008)

    Google Scholar 

  7. Horster, S., Stemmler, H.J., Strecker, N., Brettner, F., Hausmann, A., Cnossen, J., Parhofer, K.G., Nickel, T., Geiger, S.: Cardiac output measurements in septic patients: comparing the accuracy of USCOM and PiCCO. Crit. Care Res. Pract. (2012)

    Google Scholar 

  8. Jain, S., Vafa, A., Margulies, D.R., Liu, W., Wilson, M.T., Allins, A.D.: Non-invasive Doppler ultrasonography for assessing cardiac function: can it replace the Swan-Ganz catheter? Am. J. Surg. 196(6), 961–967 (2008)

    Article  Google Scholar 

  9. Cybulski, G.: Ambulatory: Impedance Cardiography—The Systems and Their Applications. Springer, New York (2011)

    Book  Google Scholar 

  10. Carvalho, P., Paiva, R.P., Henriques, J., Antunes, M., Quintal, I., Muehlsteff, J.: Robust characteristic points for ICG: definition and comparative analysis. In: Proceedings of the International Conference on Bio-inspired Systems and Signal Processing, Rome, Italy (2011)

    Google Scholar 

  11. Vincent, J.-L.: Understanding cardiac output. Crit. Care 12(4), 174 (2008)

    Article  Google Scholar 

Download references

Acknowledgements

We would like to thank the Ministry of Science and Technology (MOST), Hanoi University of Science and Technology (HUST), Viet Duc hospital, Hanoi Heart hospital for their support and encouragement. The system was designed and developed by the faculties and students at the Biomedical Electronics Center (BMEC).

Conflict of Interest The authors declare that they have no conflict of interest.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Vu Duy Hai .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Hai, V.D. et al. (2020). Design of Noninvasive Hemodynamic Monitoring Equipment Using Impedance Cardiography. In: Van Toi , V., Le, T., Ngo, H., Nguyen, TH. (eds) 7th International Conference on the Development of Biomedical Engineering in Vietnam (BME7). BME 2018. IFMBE Proceedings, vol 69. Springer, Singapore. https://doi.org/10.1007/978-981-13-5859-3_1

Download citation

  • DOI: https://doi.org/10.1007/978-981-13-5859-3_1

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-13-5858-6

  • Online ISBN: 978-981-13-5859-3

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics