Abstract

The objectives of this article were to review the literature on endodontic procedures published in various journals during the last two decades. The various obturation techniques, viz. single -cone technique, multiple-cone technique, chemo-plasticized gutta-percha, thermo-plasticized injectable gutta-percha, obturation using pastes, and SPAD/resorcinol formaldehyde, have been described and compared. The various methods used for qualitative and quantitative evaluation of micro-leakage, viz. micro-computed tomography, radiography, CT scans, cone-beam computed tomography, scanning electron microscope, fluid filtration method, dye penetration test, and bacterial leakage technique, have been described and studied by various researchers. The consultation with endodontic experts indicates that substantial improvements can be recommended on obturation procedure, and also, a few modifications may be required in obturation devices from productivity as well as ergonomics point of view. A total of 250 research papers and patents (19 Nos) have been shortlisted for conducting literature survey. The shortlisted paper was classified into various categories, viz. root canal obturation techniques (63 Nos), micro-leakage evaluation techniques (80 Nos), and root canal obturation sealing ability (75 Nos), root canal obturator design (36 Nos), and root canal geometrical parameters (25 Nos). The following statements are deduced from the above literature survey: (1) End outcome of the comparison of the various techniques revealed that warm vertical condensation is the best technique. (2) Consultation with the experts revealed that there is a need of obturator device which combines heat and vibration source. (3) The fluid filtration is the best technique as compared to other experimental techniques. Micro-computed tomography is the best qualitative and nondestructive technique. (4) There is a need for the development of an analytical model which can quantify the root canal obturation.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Ghorpade, R.R.: Deformation studies of endodontic obturator tip using FEM approach. Int. J. Eng. Inven. 1(4), 19–26 (2012)

    Google Scholar 

  2. Jain, S., Du Toit, J., Montalli, V.: Contemporary Book on Root Canal Obturation, 1st edn. India (2014)

    Google Scholar 

  3. Cifticia, A.: Coronal micro leakage of four endodontic temporary restorative materials: an in vitro study. Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endo. 108, 067–070 (2009)

    Article  Google Scholar 

  4. Moradi, S.: Comparison of fluid filtration and bacterial leakage techniques for evaluation of micro-leakage techniques in endodontics. Dent. Res. J. 12(2), 109–114 (2013)

    Google Scholar 

  5. Schilder, H.: Filling of root canals in three dimensions. J. Endod. 32(4), 281–290 (2006)

    Google Scholar 

  6. Timpawat, S.: An in vitro study of the comparative effectiveness of obturating curved root canals with gutta-percha cones, silver cones and stainless steel files. Oral Surg. Oral Med. Oral Pathol. 55(2), 180–185 (1983)

    Article  Google Scholar 

  7. Bradshaw, G.B.: The sealing ability of injection-molded thermo-plasticized gutta-percha. Int. Endod. J. 22(1), 17–20 (1989)

    Article  Google Scholar 

  8. Saunders, E.M.: The effect of variation in thermo-mechanical compaction techniques upon the quality of apical seal. Int. Endod. J. 22(4), 163–168 (1989)

    Article  Google Scholar 

  9. Hata, G.: Sealing ability of thermo-plasticized gutta-percha fill techniques as assessed by a new method of determining apical leakage. Int. Endod. J. 21(4), 167–172 (1995)

    Article  Google Scholar 

  10. Sutrave, S. Dr.: Apical sealing ability of gutta-percha by lateral condensation, chloroform dip and eucalyptol dip obturation technique: an in vitro study. Endodontology 7, 1–7 (1995)

    Google Scholar 

  11. Girhotra, R.: Scanning electron microscopic evaluation of sealing ability of root canals with various obturation techniques. Endodontology 11, 15–20 (1999)

    Google Scholar 

  12. Al-dewani, N.: Comparison of laterally condensed and low temperature thermo-plasticized gutta-percha root canal fillings. Int. J. Endod. 26(12), 733–738 (2000)

    Google Scholar 

  13. Deitch, A.K.: A comparison of fill density obtained by supplenting cold lateral condensation with ultrasonic condensation. J. Endod. 28(9), 665–667 (2002)

    Article  Google Scholar 

  14. Nevares, J.: Efficacy of pro-taper next compared with reciproc in removing obturation material from severely curved root canals a micro-computed tomography study. Basic Res. Technol. 42, 803–808 (2016)

    Article  Google Scholar 

  15. Whitworth, J.: Methods of filling root canals: principles and practices. Endodontics 12, 2–24 (2005)

    Article  Google Scholar 

  16. Aslan, H.: Evaluating root canal configuration of mandibular incisor with cone beam computed tomography in a Turkish population. J. Dent. Sci. 10, 359–364 (2014)

    Google Scholar 

  17. Angerame, D.: Resistance of endodontically treated roots restored with different fiber post systems with or without post space preparation in vitro analysis and SEM investigation. Endodonzia 30, 111–119 (2016)

    Article  Google Scholar 

  18. Shaikh, A.: A novel approach to construction and working of fluid filtration model: an experimental study. J. Sci. Innov. Res. 6(2), 55–58 (2017)

    Google Scholar 

  19. Landolo, A.: 3D cleaning, a perfected technique: thermal profile assessment of heated NaOCl. Endodonzia 118, 1–4 (2017)

    Google Scholar 

  20. Chi, C.W.: Cyclic fatigue behavior of nickel-titanium dental rotary files in clinical simulated root canals. J. Fromason Med. Assoc. 116, 306–312 (2016)

    Article  Google Scholar 

  21. Mothanna, K.: Technical quality assessment of root canal treatment performed by pre-clinical dental students at Taibah university. Mater. Sci. 41, 27–32 (2016)

    Google Scholar 

  22. Eken, R.: Evaluation of the effect of rotary systems on stress in new testing model using a 3-dimensional printed simulated resin root with an oval shaped canal a finite element analysis study. J. Endod. 42(8), 1273–1278 (2016)

    Article  Google Scholar 

  23. Wei, Qu: Influence of warm vertical compaction techniques on physical properties of root canal sealers. J. Endod. 42(12), 1829–1833 (2016)

    Article  Google Scholar 

  24. Ruyan, W.: Evaluation of effect of needle position on irrigant flow in the c-shaped root canal using computational fluid dynamics model. J. Endod. 41(6), 931–936 (2015)

    Article  Google Scholar 

  25. Viapiana, R.: Investigation of effect of sealer use on the heat generated at external root surface during root canal obturation using warm vertical compaction technique with system B heat sources. J. Endod. 40(4), 555–561 (2014)

    Google Scholar 

  26. Ghorpade, R.R.: Experimental and FEA based modal analysis of scaled up dental pin/plugger-case study in Endodontics. Int. J. Res. Advent Technol. 1(5), 15–22 (2013)

    Google Scholar 

  27. Ghorpade, R.R.: Thermal and stress analysis of gutta-percha in simulated root canal using finite element analysis. Int. J. Mech. Prod. Eng. Res. Dev. 2(4), 19–30 (2012)

    Google Scholar 

  28. Ratnakar, R.: Ghorpade.: Penetration depth of heated plugger on softened gutta-percha. E. J. Dent. 2(4), 251–259 (2012)

    Google Scholar 

  29. Ghorpade, R.R.: Fluid structure interaction during root canal obturation FEA based case study in Endodontics. In: Technical Journal of the Institution of Engineers, pp. 230–235. Pune Local Centre, India (2014)

    Google Scholar 

  30. Angerame, D.: Quality of canal obturation assessed by micro-computed tomography influence of filling technique and post placement in canal shape with reciproc. Endodonzia 41, 82–85 (2013)

    Google Scholar 

Download references

Acknowledgments

The author acknowledges the support and guidance received from Dr. Vivek Hagade of MA Rangoonwala College of Dental Sciences and Research Centre Pune, India; Dr. Srinidhi S. R. of Sinhgad Dental College and Hospital Pune, India-411041; Shivam Dental Laboratory Pune, India-411046; Sculptdent Dental Lab Ghorpadi, Pune, India-411003, for this Ph.D. research work. The authors also thank Shikha Damodhar Bobhate, first-year PG student M.E. Design Engineering, NBN Sinhgad School of Engineering, Ambegaon Bk, Pune, India-411 046, for assisting during completion of this review article.

The authors thank Dr. S. Koteeswaran (dean—research studies) and Dr. A. P. Ravichandran (head of mechanical engineering department) of VelTech University, Chennai, for approval of topic and for their insightful comments, encouragement, and love.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Pravin R. Lokhande .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Lokhande, P.R., Deenadayalan, Ghorpade, R.R., Srinidhi, S.R. (2019). A Review of Contemporary Research on Root Canal Obturation and Related Quality Assessment Techniques. In: Chandrasekhar, U., Yang, LJ., Gowthaman, S. (eds) Innovative Design, Analysis and Development Practices in Aerospace and Automotive Engineering (I-DAD 2018). Lecture Notes in Mechanical Engineering. Springer, Singapore. https://doi.org/10.1007/978-981-13-2697-4_55

Download citation

  • DOI: https://doi.org/10.1007/978-981-13-2697-4_55

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-13-2696-7

  • Online ISBN: 978-981-13-2697-4

  • eBook Packages: EngineeringEngineering (R0)

Publish with us