Abstract
High strength concrete (HSC) is predominantly used in high-rise reinforced concrete buildings. While excellent from strength point of view at room temperature, HSC is known to be prone to spalling, when exposed to high temperatures (e.g., in case of a fire). Fire resistance evaluated from building codes (CEN in Design of concrete structures. Part 1–2: general rules—structural fire design, Eurocode-2, Brussels, 2004; Bureau of Indian Standards in Indian code of practice for fire safety of buildings (General): details of construction code of practice. IS-1641, New Delhi, 1989) [1, 2] and simulation-based studies typically does not consider the effects of spalling. To alleviate these difficulties, a 2-D hydrothermal model has been developed for predicting the extent of spalling in HSC. The numerical model evaluates pore pressure inside the concrete as a function of time using the laws of thermodynamics. Spalling is said to occur when the pore pressure built-up within concrete exceeds its tensile strength. The model depends on several parameters such as permeability, initial moisture content, and thermomechanical properties of concrete. All of these parameters are considered by the model through a two-way coupling between the pore pressure analysis and thermal analysis, both implemented using the finite element method. Validity of the numerical example is established by comparing the spalling predictions obtained from the numerical model against standard experiments available in the literature. Parametric studies have also been performed using the numerical model to quantify the effects of model parameters such as permeability, grade of concrete, and type of fire scenario on the prediction of spalling.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
CEN (European committee for Standardization). (2004). Design of concrete structures. Part 1–2: General rules—Structural fire design. Brussels: Eurocode-2.
Bureau of Indian Standards. (1989). Indian code of practice for fire safety of buildings (General): Details of construction-code of practice. New Delhi: IS-1641.
Phan, L. T. (1996). Fire performance of high-strength concrete: A report of the state-of-the art. US Department of Commerce, Technology Administration, National Institute of Standards and Technology, Office of Applied Economics, Building and Fire Research Laboratory.
Diederichs, U., Jumppanen, U. M., & Schneider, U. (1995). High temperature properties and spalling behaviour of high strength concrete. In Proceedings of Fourth Weimar Workshop on High Performance Concrete (pp. 219–235). Germany: HAB Weimar.
Kodur, V. K. R. (2000). Spalling in high strength concrete exposed to fire—Concerns, causes, critical parameters and cures. In Proceedings, ASCE Structures Congress (pp. 1–8), Philadelphia, PA, USA.
Gawin, D., Majorana, C. E., & Schrefler, B. A. (1999). Numerical analysis of hygro-thermal behaviour and damage of concrete at high temperature. Mechanics of Cohesive-fictional Materials, 4(1), 37–74.
Gawin, D., Pesavento, F., & Schrefler, B. A. (2006). Towards prediction of the thermal spalling risk through a multi-phase porous media model of concrete. Computer Methods in Applied Mechanics and Engineering, 195(41), 5707–5729.
Kodur, V. K. R., Wang, T. C., & Cheng, F. P. (2004). Predicting the fire resistance behaviour of high strength concrete columns. Cement and Concrete Composites, 26(2), 141–153.
ACI 216.1 M-07. (2007). Standard method for determining fire resistance of concrete and masonry construction assemblies. Detroit, USA: American Concrete Institute.
Dwaikat, M. B., & Kodur, V. K. R. (2009). Hydrothermal model for predicting fire-induced spalling in concrete structural systems. Fire Safety Journal, 44(3), 425–434.
Bazant, Z. P., & Thonguthai, W. (1978). Pore pressure and drying of concrete at high temperature. Journal of Engineering Mechanics, 104(5), 1059–1079.
Prakash, P. R., & Srivastava, G. (2015). Development of a matrix method based framework for the thermo-mechanical analysis of RCC frames. In Response of Structures Under Extreme Loading: Proceedings of PROTECT-2015, pp. 972–980.
ASTM. (2001). Standard methods of fire test of building construction and materials, Test Method. West Conshohocken: American Society for Testing and Materials.
Cook, R. D., Malkus, D. S., Plesha, M. E., & Witt, R. J. (2007). Concepts and applications of finite element analysis. Berlin: Wiley.
Rots J. G., Kusters, G. M. A., & Blaauwendraad, J. (1984). The need for fracture mechanics options in finite element models for concrete structures. In International Conference on Computer Aided Analysis and Design of Concrete Structures, pp. 19–32.
Bilodeau, A., Kodur, V. K. R., & Hoff, G. C. (2004). Optimization of the type and amount of polypropylene fibres for preventing the spalling of lightweight concrete subjected to hydrocarbon fire. Cement and Concrete Composites, 26(2), 163–174.
Dwaikat, M. B., & Kodur, V. K. R. (2010). Fire induced spalling in high strength concrete beams. Fire Technology, 46(1), 251–274.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Prakash, P.R., Srivastava, G. (2019). Numerical Modeling of Spalling in High Strength Concrete at High Temperature. In: Rao, A., Ramanjaneyulu, K. (eds) Recent Advances in Structural Engineering, Volume 1. Lecture Notes in Civil Engineering , vol 11. Springer, Singapore. https://doi.org/10.1007/978-981-13-0362-3_34
Download citation
DOI: https://doi.org/10.1007/978-981-13-0362-3_34
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-13-0361-6
Online ISBN: 978-981-13-0362-3
eBook Packages: EngineeringEngineering (R0)