Abstract
When metal implants are present in the field of measurement, artifacts degrade image quality. Metal artifact reduction (MAR) methods produce images with improved quality leading to confident and reliable clinical diagnosis. Currently, there are many methods developed, but no generally accepted solution to this issue has been found. In this work we propose a morphological image filtering approach for metal artifact reduction (MIFMAR) algorithm for image quality improvement. MIFMAR performance was compared with three well-known MAR methods, which are linear interpolation (LI), normalized metal artifact reduction (NMAR) and frequency split metal artifact reduction (FSMAR), using clinical studies. The methods were applied to images acquired from 30 clinical studies of patients with metallic implants. Image quality was evaluated by three experienced radiologists completely blinded to the information about if the image was processed or not to suppress the artifacts. They graded image quality in a five points-scale, where zero is an index of clear artifact presence, and five, a whole artifact suppression. Image quality on images were compared using the non-parametric Friedman-ANOVA test. Inter-observer agreement was evaluated using linear-weighted κ test. MIFMAR ensures efficient reduction of metal artifacts with high image quality, preserving all of tissues and details in CT images. Image quality and diagnostic scores improved significantly (p < 0.01) with good inter-observer agreement. MIFMAR is computationally inexpensive compared with other methods and does not use raw CT data.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Fang, J., Zhang, D., Wilcox, C., Heidinger, B., Raptopoulos, V., Brook, A., Brook, O.R.: Metal implants on CT: comparison of iterative reconstruction algorithms for reduction of metal artifacts with single energy and spectral CT scanning in a phantom model. Abdom. Radiol. 42, 742–748 (2017).
Guggenberger, R., Winklhofer, S., Osterhoff, G., Wanner, G.A., Fortunati, M., Andreisek, G., Alkadhi, H., Stolzmann, P.: Metallic artefact reduction with monoenergetic dual-energy CT: systematic ex vivo evaluation of posterior spinal fusion implants from various vendors and different spine levels. Eur. Radiol. 22, 2357–2364 (2017).
Meyer, E., Raupach, R., Lell, M., Schmidt, B., Kachelrieß, M.: Normalized metal artifact reduction (NMAR) in computed tomography. Med. Phys. 37, 5482–5493 (2010).
Meyer, E., Raupach, R., Lell, M., Schmidt, B., Kachelrieß, M.: Frequency split metal artifact reduction (FSMAR) in computed tomography. Med. Phys. 39, 1904–1916 (2012).
Zhang, H., Wang, L., Li, L., Cai, A., Hu, G., Yan, B.: Iterative metal artifact reduction for x-ray computed tomography using unmatched projector/backprojector pairs. Med. Phys. 43, 3019–3033 (2016).
Naranjo, V., Lloréns, R., Alcañiz, M., López-Mir, F.: Metal artifact reduction in dental CT images using polar mathematical morphology. Comput. Methods Programs Biomed. 102, 64–74 (2011).
Kalender, W.A., Hebel, R., Ebersberger, J.: Reduction of CT artifacts caused by metallic implants. Radiology. 164, 576–577 (1987).
Zhang, Y., Yan, H., Jia, X., Yang, J., Jiang, S.B., Mou, X.: A hybrid metal artifact reduction algorithm for x-ray CT. Med Phys. 40, 4 (2013).
Xu, L., Lu, C., Xu, Y., Jia, J.: Image Smoothing via L0 Gradient Minimization. ACM Trans Graph. 30, 174:1–174:12 (2011).
Golden, C., Mazin, S.R., Boas, F.E., Tye, G., Ghanouni, P., Gold, G., Sofilos, M., Pelc, N.J.: A comparison of four algorithms for metal artifact reduction in CT imaging. In: Proc. SPIE. p. 79612Y (2011).
Acknowledgements
The authors would like to thank Professor Dr. Norbert Pelc from Stanford University and Dr. Samuel Mazin from RefleXion Medical for proving clinical data.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Ethics declarations
The authors declare that they have no conflict of interest.
Rights and permissions
Copyright information
© 2019 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Rodríguez-Gallo, Y., Orozco-Morales, R., Pérez-Díaz, M. (2019). Metal Artifact Reduction by Morphological Image Filtering for Computed Tomography. In: Lhotska, L., Sukupova, L., Lacković, I., Ibbott, G.S. (eds) World Congress on Medical Physics and Biomedical Engineering 2018. IFMBE Proceedings, vol 68/1. Springer, Singapore. https://doi.org/10.1007/978-981-10-9035-6_39
Download citation
DOI: https://doi.org/10.1007/978-981-10-9035-6_39
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-9034-9
Online ISBN: 978-981-10-9035-6
eBook Packages: EngineeringEngineering (R0)