Abstract
Arterial pulse waves (PWs) provide information on the vascular health and could be utilized in the early detection of atherosclerosis. The aim of the study is to characterize the short-term repeatability of combined finger and toe photoplethysmographic (PPG) signal analysis method which we call finger-toe plot (FT-plot) and compare it with other methods proposed for vascular characterization. PPG signals were recorded from 24 atherosclerotic and 47 control subjects from finger and toe. The repeatability of the method was analyzed by means of intra-class correlation coefficients (ICC) and free-marginal multirater \(\kappa \) agreement. The metrics were computed for individual PWs as well as for averages based on 10–100 PWs. The ICCs increased with number of PWs utilized — ICCs and \(\kappa \) agreements higher than \(\ge 0.90\) were widely achieved based on the averages of \(\ge 20\) PWs, depending on the parameter or study group. Based on the present results, the FT-plot based detection of atherosclerotic changes has at least equal repeatability compared with a current clinical standard, ankle-to-brachial pressure index. However, further studies should validate the findings before the method is ready for the screening of atherosclerotic changes.
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Oren, A., Vos, L.E., Uiterwaal, C.S.P.M., Grobbee, D.E., Bots, M.L.: Aortic stiffness and carotid intima-media thickness: two independent markers of subclinical vascular damage in young adults? European journal of clinical investigation. 33, 949–954 (2003)
Wykretowicz, A., Gerstenberger, P., Guzik, P., et al.: Arterial stiffness in relation to subclinical atherosclerosis European journal of clinical investigation. 39, 11–16 (2009)
Popele, N.M., Grobbee, D.E., Bots, M.L., et al.: Association between arterial stiffness and atherosclerosis The Rotterdam Study Stroke. 32, 454–460 (2001)
Suominen, V., Rantanen, T., Venermo, M., Saarinen, J., Salenius, J.: Prevalence and risk factors of PAD among patients with elevated ABI European Journal of Vascular and Endovascular Surgery. 35, 709–714 (2008)
Crilly, M., Coch, C., Clark, H., Bruce, M., Williams, D.: Repeatability of the measurement of augmentation index in the clinical assessment of arterial stiffness using radial applanation tonometry. Scandinavian Journal of Clinical & Laboratory Investigation. 67, 413–422 (2007)
Peltokangas M., Telembeci A. A., Verho J., et al. Parameters extracted from arterial pulse waves as markers of atherosclerotic changes: performance and repeatability IEEE Journal of Biomedical and Health Informatics. . In press. DOI: 10.1109/JBHI.2017.2679904
Peltokangas, M., Vehkaoja, A., Huotari, M., et al.: Combining finger and toe photoplethysmograms for the detection of atherosclerosis Physiological Measurement. 38, 139 (2017)
Peltokangas, M., Vehkaoja, A., Verho, J., Huotari, M., Rning, J., Lekkala, J.: Monitoring Arterial Pulse Waves With Synchronous Body Sensor Network Biomedical and Health Informatics. IEEE Journal of. 18, 1781–1787 (2014)
Schuck, P.: Assessing reproducibility for interval data in health-related quality of life questionnaires: which coefficient should be used? Quality of Life Research. 13, 571–585 (2004)
Randolph JJ. Free-Marginal Multirater Kappa (multirater \(\kappa \)free): An Alternative to Fleiss’ Fixed-Marginal Multirater Kappa in Presented at the Joensuu Learning and Instruction Symposium;2005 2005
Holland-Letz, T., Endres, H.G., Biedermann, S., et al.: Reproducibility and reliability of the ankle-brachial index as assessed by vascular experts, family physicians and nurses. Vascular Medicine. 12, 105–112 (2007)
Osmundson, P.J., O’Fallon, W.M., Clements, I.P., Kazmier, F.J., Zimmerman, B.R., Palumbo, P.J.: Reproducibility of noninvasive tests of peripheral occlusive arterial disease Journal of vascular surgery. 2, 678–683 (1985)
Fisher, C.M., Burnett, A., Makeham, V., Kidd, J., Glasson, M., Harris, J.P.: Variation in measurement of ankle-brachial pressure index in routine clinical practice Journal of vascular surgery. 24, 871–875 (1996)
Al-Qunaibet, A., Meyer, M.L., Couper, D., et al.: Repeatability of Oscillometric Determinations of the Ankle-Brachial Index, p. 2016. Open Access, The Atherosclerosis Risk in Communities (ARIC) Study Angiology (2016)
Atsma, M.-L., Grobbee, D.E., Schouw, Y.T.: Best reproducibility of the ankle-arm index was calculated using Doppler and dividing highest ankle pressure by highest arm pressure Journal of clinical epidemiology. 58, 1282–1288 (2005)
Wohlfahrt, P., Ingrischová, M., Krajaoviechova, A., et al.: A novel oscillometric device for peripheral arterial disease screening in everyday practice. The Czech-post MONICA study International Angiology. 30, 256 (2011)
Wowern, E., Östling, G., Nilsson, P.M., Olofsson, P.: Digital Photoplethysmography for Assessment of Arterial Stiffness: Repeatability and Comparison with Applanation Tonometry PloS one. 10, e0135659 (2015)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Peltokangas, M. et al. (2018). Short-term stability of combined finger and toe photoplethysmogram analysis. In: Eskola, H., Väisänen, O., Viik, J., Hyttinen, J. (eds) EMBEC & NBC 2017. EMBEC NBC 2017 2017. IFMBE Proceedings, vol 65. Springer, Singapore. https://doi.org/10.1007/978-981-10-5122-7_86
Download citation
DOI: https://doi.org/10.1007/978-981-10-5122-7_86
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-5121-0
Online ISBN: 978-981-10-5122-7
eBook Packages: EngineeringEngineering (R0)