Abstract
Dental implants are widely used in oral and maxillofacial surgery. In clinics, accurate measurements of implants biomechanical stability are of interest since they could be used to improve the surgical strategy by adapting the choice of the healing period to each patient. Experiments using 10 MHz ultrasound device show significant effects of the amount and quality of bone in contact with the implant on the ultrasonic responses measured. In this paper, we present some numerical results for studying the sensitivity of the ultrasonic response of the implant to variations of the quantity and quality of bone tissue in contact with the implant is assessed under realistic conditions. A 3D finite element model which is based on experimental measurements was developed in order to account for the evolution of the bone biomechanical properties at the implant interface. Based on the reproducibility of the measurement, the results indicate that the device should be sensitive to the effects of a healing duration of less than one week. In all cases, the amplitude of the implant response is shown to decrease when the dental implant primary and secondary stability increase, which is consistent with the experimental results. Moreover, the effect of osseointegration phenomena in a layer between bone tissue and the implant is modeled. The numerical results show that the implant ultrasonic response changes significantly when a liquid layer is located at the implant interface compared to the case of an interface fully bounded with bone tissue.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Njeh CF et al (1999) An in vitro investigation of the dependence on sample thickness of the speed of sound along the specimen. Med Eng Phys 21(9):651–659
Pattijn V et al (2006) The resonance frequencies and mode shapes of dental implants: Rigid body behaviour versus bending behaviour. A numerical approach. J Biomech 39(5):939–947
Haiat G et al (2007) Variation of ultrasonic parameters with microstructure and material properties of trabecular bone: a 3D model simulation. J Bone Miner Res 22(5):665–674
Sasso M et al (2008) Dependence of ultrasonic attenuation to bone mass and microstructure in bovine cortical bone. J Biomech 41(2):347–355
Mathieu V et al (2011) Ultrasonic evaluation of dental implant biomechanical stability: an in vitro study. Ultrasound Med Biol 37(2):262–270
Vayron R et al (2014) Assessment of the in vitro dental implant primary stability using an ultrasonic method. Ultrasound Med Biol 40(12):2885–2894
Mathieu V et al (2014) Biomechanical determinants of the stability of dental implants: influence of the bone-implant interface properties. J Biomech 47:3–13
Vayron R et al (2015) Finite element simulation of ultrasonic wave propagation in a dental implant for biomechanical stability assessment. Biomech Model Mechan 14:1021–1032
Mathieu V et al (2011) Micro-Brillouin scattering measurements in mature and newly formed bone tissue surrounding an implant. J Biomech Eng-T Asme 133(2):021006–6
Vayron R et al (2014) Evolution of bone biomechanical properties at the micrometer scale around titanium implant as a function of healing time. Phys Med Biol 59(6):1389–1406
Vayron R et al (2011) Variation of biomechanical properties of newly formed bone tissue determined by nanoindentation as a function of healing time. Comput Methods Biomech Biomed Eng 14:139–140
Vayron R et al (2012) Nanoindentation measurements of biomechanical properties in mature and newly formed bone tissue surrounding an implant. J Biomech Eng 134(2):021007
Vayron R et al (2013) Variation of the ultrasonic response of a dental implant embedded in tricalcium silicate-based cement under cyclic loading. J Biomech 46:1162–1168
Mathieu V et al (2011) Numerical simulation of ultrasonic wave propagation for the evaluation of dental implant biomechanical stability. J Acoust Soc Am 129(6):4062–4072
Blanco J et al (2011) Influence on early osseointegration of dental implants installed with two different drilling protocols: a histomorphometric study in rabbit. Clin Oral Implants Res. 22(1):92–99
Vayron R et al (2016) Assessment of dental implant biomechanical stability using quantitative ultrasound: a 3-D finite element study. J Acoust Soc Am 139(2):773–780
Acknowledgements
This work has been supported by French National Research Agency (ANR) through the PRTS program (project OsseoWave ANR-13-PRTS-0015). The research of the V.-H. Nguyen and S. Naili is supported by the CNRS-UPE project PEPS-2015-5.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Vayron, R., Nguyen, VH., Naili, S., Haïat, G. (2018). Ultrasound Assessment of Dental Implant Stability: Finite Element Analysis of Wave Propagation. In: Vo Van, T., Nguyen Le, T., Nguyen Duc, T. (eds) 6th International Conference on the Development of Biomedical Engineering in Vietnam (BME6) . BME 2017. IFMBE Proceedings, vol 63. Springer, Singapore. https://doi.org/10.1007/978-981-10-4361-1_65
Download citation
DOI: https://doi.org/10.1007/978-981-10-4361-1_65
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-4360-4
Online ISBN: 978-981-10-4361-1
eBook Packages: EngineeringEngineering (R0)