Implanting Two Fiducials into the Liver with Single Needle Insertion Under CT Guidance for CyberKnife® SBRT

  • Conference paper
  • First Online:
Frontier and Future Development of Information Technology in Medicine and Education

Part of the book series: Lecture Notes in Electrical Engineering ((LNEE,volume 269))

  • 152 Accesses

Abstract

Purpose We implanted four to six fiducial markers before treating liver tumors with CyberKnife® to allow image-guided positioning before treatment and real-time tracking during treatment. In the conventional implanting technique, a needle insertion is required to place each fiducial, i.e., patients would receive four to six needle punctures. To improve efficiency and reduce the time required for the procedure, not to mention the pain and risks of fiducial implantation, we invented a technique whereby two fiducials are implanted with each needle insertion. Methods and Materials Liver tumors constitute the most common disease treated at our radiotherapy center. From August 2011 to July 2012, 429 patients with liver tumors underwent fiducial implantation with the technique of one-needle insertion placing two fiducials at a time. Ages varied 19–74 years old. In total, 1252 fiducials were implanted with this technique. For the new technique, an initial CT image of the tumor was used to determine the implanting depth and angle of the first fiducial marker. The first fiducial was placed using an 18-gauge needle, and the needle stylet and set remain stationary for 3–5 min, after which it was slowly pulled 3–5 cm out, and then the second fiducial was released. Another image of the fiducials was acquired to assess the distance between the fiducials, their angle with respect to each other, and their compliance with the requirements of fiducial placement before continuing the procedure. Results Among the 1252 fiducials implanted with the technique, 18 (1.44 %) had a distance smaller than 20 mm between each other, 24 (1.92 %) were collinear at 45° vantage point, 17 (1.04 %) migrated to other organs, and the success rate was 95.28 %. With this technique, 626 punctures were required whereas 1252 punctures would have been needed with the conventional technique. Besides, implanting with a 35°–5° angle makes fiducials collinear in the 45° direction. For some patients, for whom the two-fiducial insertion technique required a puncture deeper than 5 cm, the fiducials were inserted one by one. Conclusion Dual fiducial insertion doubles the implanting efficiency and halves the number of punctures so that the costs and risks are both reduced. The distance between fiducials being smaller than 20 mm and collinear fiducials at the 45° angle direction are the most common complications affecting success rate.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 429.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 549.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 549.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Kuo JS, Yu C, Petrovich Z, Apuzzo ML (2003) The CyberKnife stereotactic radiosurgery system: description, installation, and an initial evaluation of use and functionality. Neurosurgery 53:1235–1239

    Article  Google Scholar 

  2. Chan SD, Main W, Martin DP, Gibbs IC, Heilbrun MP (2003) An analysis of the accuracy of the CyberKnife:a robotic frameless stereotactic radiosurgical system. Neurosurgery 52:140–146

    Google Scholar 

  3. Wunderink W, Mendez Romero A, de Kruijf W et al (2008) Reduction of respiratory liver tumor motion by abdominal compression in stereotactic body frame, analyzed by tracking fiducial markers implanted in liver. Int J Radiat Oncol Biol Phys 71:907–915

    Google Scholar 

  4. Kim JH, Hong SS, Kim JH et al (2012) Safety and efficacy of ultrasound-guide fiducial marker implantation for CyberKnife radiation therapy. Korean J Radiol 13(3):307–313

    Google Scholar 

  5. Anantham D, Feller-Kopman D, Shanmugham LN et al (2007) Electromagnetic navigation bronchoscopy-guided fiducial placement for robotic stereotactic radiosurgery of lung tumors. Chest 132(3):930–935

    Google Scholar 

  6. Mallarajapatna GJ, Susheela SP, Kallur KG et al (2011) Image guided internal fiducial placement for stereotactic radiosurgery (CyberKnife). Indian J Radiol Imag 21:3–5

    Article  Google Scholar 

  7. Kothary N, Dieterich S, Louie JD et al (2009) Percutaneous implantation of fiducial markers for imaging-guided radiation therapy. AJR 192:1090–1095

    Google Scholar 

  8. Berbeco RI, Nishioka S, Shirato H et al (2005) Residual motion of lung tumors in gate radiotherapy with external respiratory surrogates. Phys Med Biol 50:3655–3667

    Article  Google Scholar 

  9. Ryu SI, Chang SD, Kim DH et al (2001) Image-guide hypo-fractionated stereotactic radiosurgery to spinal lesions. Neurosurgery 49:838–846

    Google Scholar 

  10. Kothary N, Heit JJ, Louie JD et al (2009) Safety and efficacy of percutaneous fiducial marker implantation for image-guide radiation. J Vasc Interv Radiol 20(2):235–239

    Google Scholar 

  11. Dieterich Sonja et al (2011) Quality assurance for robotic radiosurgery: report of the AAPM task group 135. Med Phys 38(6):2924–2926

    Google Scholar 

  12. Quinn AM (2002) CyberKnife: a robotic radiosurgery system. Clin J Oncol Nurs 6:149–156

    Article  Google Scholar 

  13. Lee C (2012) Airway migration of lung fiducial marker after autologous blood-patch injection. Cardiovasc Intervent Radiol 35:711–713

    Article  Google Scholar 

  14. Kupelian P, Forbes A, Willoughby T et al (2007) Implantation and stability of metallic fiducials within pulmonary lesions. Int J Radiat Oncol Biol Phys 69:777–785

    Google Scholar 

  15. Shirato H, Harada T, Harabayshi T et al (2003) Feasibility of insertion/implantation of 2.0 –mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy. Int J Radiat Oncol Biol Phys 56:240–247

    Google Scholar 

  16. Sotiropoulou E, Stathochristopoulou I, Stathopoulos K et al (2010) CT-guided fiducial placement for CyberKnife stereotactic radiosurgery: an initial experience. Cardiovasc Intervent Radiol 33:586–589

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Xu Hui-jun .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2014 Springer Science+Business Media Dordrecht

About this paper

Cite this paper

Yu, L., Hui-jun, X., Su-jing, Z. (2014). Implanting Two Fiducials into the Liver with Single Needle Insertion Under CT Guidance for CyberKnife® SBRT. In: Li, S., Jin, Q., Jiang, X., Park, J. (eds) Frontier and Future Development of Information Technology in Medicine and Education. Lecture Notes in Electrical Engineering, vol 269. Springer, Dordrecht. https://doi.org/10.1007/978-94-007-7618-0_15

Download citation

  • DOI: https://doi.org/10.1007/978-94-007-7618-0_15

  • Published:

  • Publisher Name: Springer, Dordrecht

  • Print ISBN: 978-94-007-7617-3

  • Online ISBN: 978-94-007-7618-0

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics