Skip to main content

PDA Stenting in Duct-Dependent Pulmonary Circulation

  • Chapter
  • First Online:
Cardiac Catheterization for Congenital Heart Disease

Abstract

Surgical aortopulmonary shunts palliate neonates with duct-dependent pulmonary circulation. The surgical problems included prolonged mechanical ventilation and intensive care stays, bleeding and transfusions, frequent use of multiple inotropes, pulmonary complications, sepsis, and injury to surrounding structures like phrenic nerve, recurrent laryngeal nerve, and thoracic duct. Ductal stenting (DS) provides a nonsurgical attractive alternative option to surgical aortopulmonary shunts. On follow-up after both procedures, there is a progressive fall in oxygen levels due to intimal ingrowth within the ductal stents and fibrointimal peel formation and thrombus within surgical shunts. 5–20 % of patients suddenly die on follow-up due to shunt or stent thrombosis. While the surgical shunts offer a longer palliation of few years, DS gives longevity of only 6–12 months. This difference in duration of palliation will influence patient selection for DS.

This review describes the different indications and contraindications, procedural details, complications, and post-procedural follow-up after DS.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 79.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Sivakumar K, Bhagyavathy A, Coelho R, Satish R, Krishnan P (2012) Longevity of neonatal ductal stenting for congenital heart diseases with duct-dependent pulmonary circulation. Congenit Heart Dis 7:526–533

    Article  PubMed  Google Scholar 

  2. Alwi M, Choo KK, Haifa AL, Geetha K, Hasri S, Mulyadi MD (2004) Initial results and medium-term follow-up of stent implantation of patent ductus arteriosus in duct-dependent pulmonary circulation. J Am Coll Cardiol 44:438–445

    Article  PubMed  Google Scholar 

  3. Gewillig M, Boshoff DE, Dens J, Mertens L, Benson LN (2004) Stenting the neonatal arterial duct in duct-dependent pulmonary circulation: new techniques, better results. J Am Coll Cardiol 43:107–112

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Kothandam Sivakumar MD, DM .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2015 Springer-Verlag Italia

About this chapter

Cite this chapter

Sivakumar, K. (2015). PDA Stenting in Duct-Dependent Pulmonary Circulation. In: Butera, G., Chessa, M., Eicken, A., Thomson, J. (eds) Cardiac Catheterization for Congenital Heart Disease. Springer, Milano. https://doi.org/10.1007/978-88-470-5681-7_24

Download citation

  • DOI: https://doi.org/10.1007/978-88-470-5681-7_24

  • Published:

  • Publisher Name: Springer, Milano

  • Print ISBN: 978-88-470-5680-0

  • Online ISBN: 978-88-470-5681-7

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics