Skip to main content

Normal Ultrasound Biomicroscopy

  • Living reference work entry
  • First Online:
The Uveitis Atlas
  • 283 Accesses

Abstract

The ultrasound biomicroscopy (UBM) allows quantitative and qualitative assessment of the anterior segment. It helps us obtain cross sections for morphological assessment of the subsurface of the eye and establish diagnosis in cases where biopsy is precluded. The standard UBM operates at 50 MHz provides lateral and axial physical resolutions of approximately 50 μm and 25 μm, respectively with a depth of penetration of 4–5mm. While dealing in cases with uveitis, one must learn to examine the iris, ciliary body, pars plana and peripheral retina. The chapter describes normal appearance of structures on UBM, relevant to uveitic pathology.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Institutional subscriptions

Similar content being viewed by others

Suggested Reading

  • Dorairaj S, Liebmann JM, Ritch R. Quantitative evaluation of anterior segment parameters in the era of imaging. Trans Am Ophthalmol Soc. 2007;105:99–110.

    PubMed  PubMed Central  Google Scholar 

  • Gupta P, Gupta A, Gupta V, Singh R. Successful outcome of pars plana vitreous surgery in chronic hypotony due to uveitis. Retina. 2009;29(5):638–43.

    Article  PubMed  Google Scholar 

  • Ishikawa H. Anterior segment imaging for glaucoma: OCT or UBM? Br J Ophthalmol. 2007;91:1420–1.

    Article  PubMed  PubMed Central  Google Scholar 

  • Li H, Leung CKS, Cheung CYL, et al. Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography. Br J Ophthalmol. 2007;91:1490–2.

    Article  PubMed  PubMed Central  Google Scholar 

  • Mundt Jr GH, Hughes Jr WF. Ultrasonics in ocular diagnosis. Am J Ophthalmol. 1956;41:488–98.

    Article  PubMed  Google Scholar 

  • Pavlin CJ, Sherar MD, Foster FS. Subsurface ultrasound microscopic imaging of the intact eye. Ophthalmology. 1990;97:244–50.

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ramandeep Singh .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2016 Springer India

About this entry

Cite this entry

Kaur, S., Singh, R. (2016). Normal Ultrasound Biomicroscopy. In: Gupta, V., Nguyen, Q., LeHoang, P., Herbort Jr., C. (eds) The Uveitis Atlas. Springer, New Delhi. https://doi.org/10.1007/978-81-322-2506-5_9-1

Download citation

  • DOI: https://doi.org/10.1007/978-81-322-2506-5_9-1

  • Received:

  • Accepted:

  • Published:

  • Publisher Name: Springer, New Delhi

  • Online ISBN: 978-81-322-2506-5

  • eBook Packages: Springer Reference MedicineReference Module Medicine

Publish with us

Policies and ethics