Roller pumps play an important role in extracorporeal blood circulation. However, pump occlusion must be properly performed and be adjusted mainly by the static and the dynamic methods. Our objective is to show preliminary results of the use of an auxiliary device for roller pump calibration via the dynamic method. Simultaneous tests have been carried out with the auxiliary device and a commercial data acquisition board and three disposable pressure transducers. The device has been also tested by perfusionists during the XXVIII Congresso Brasileiro de Circulação Extracorpórea. A roller pump and needed accessories for calibration via both the static and the dynamic methods have been made available to 56 perfusionists that were asked to calibrate the roller pump as they normally do in their hospital service. After each regulation the respective mean pressure of dynamic calibration was measured with our device. Results: A comparison between our device and the commercial data acquisition board has shown statistical equality for the adjusts of dynamic calibration pressure ( p > 0.05). The mean of the 56 measurements of dynamic calibration pressure was 434 ± 214 mmHg (mean ± standard deviation) and variation coefficient was VC = 49.2 %. Our results have shown that the constructed device may be used by perfusionists to quickly adjust roller pumps with great precision and repeatability. Careful tests may be initiated with our device in operating room.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to E. T. Costa .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2013 Springer Berlin Heidelberg

About this paper

Cite this paper

Costa, E.T., Vieira Junior, F.U., de Medeiros Júnior, J.D., Antunes, N., Vieira, R.W. (2013). Testes Preliminares de Uso de um Dispositivo Auxiliar para o Ajuste de Bombas de Roletes Utilizadas em Circulação Extracorpórea. In: Folgueras Méndez, J., et al. V Latin American Congress on Biomedical Engineering CLAIB 2011 May 16-21, 2011, Habana, Cuba. IFMBE Proceedings, vol 33. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-21198-0_192

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-21198-0_192

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-21197-3

  • Online ISBN: 978-3-642-21198-0

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics