Abstract
This chapter describes the basics and the clinical experience with two explicit computerised protocols (ECP) implemented in commercialised ventilators: Smartcare/PS® by Draeger Medical (Germany) and IntelliVent® by Hamilton Medical (Switzerland). These two ECPs manage ventilation, without the need of caregivers’ intervention but under their supervision. SmartCare/PS® is an autopiloting, knowledge-based software application that provides an ECP for the automated control of pressure support ventilation. IntelliVent® is an explicit computerised protocol for the automated control of minute volume, PEEP and FiO2 in adaptive support ventilation (ASV). The main innovation of the two ECPs is the use of \( {ET}_{PCO_2} \) as a surrogate for blood gas PCO2, to decrease or increase ventilatory support. IntelliVent® also uses SpO2 to decrease or increase PEEP and FiO2. The two ECPs were studied in children during the weaning phase and the first clinical studies are promising. However, further clinical trials are needed to better assess the efficacy and tolerance of these two ECPs in children and to develop ECP that are dedicated to all ages including neonates.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Arnal J, Wysocki M, Demory D, Durish G, Laubscher T, Novotni D et al (2010) Prospective randomized cross-over controlled study comparing adaptive support ventilation (ASV) and a fully close loop control solution (Intellivent®) in adult ICU patients with acute respiratory failure. Am J Respir Crit Care Med 181:A3004 (abstract)
Boles JM, Bion J, Connors A, Herridge M, Marsh B, Melot C et al (2007) Weaning from mechanical ventilation. Eur Respir J 29(5):1033–1056
Brower RG, Lanken PN, MacIntyre N, Matthay MA, Morris A, Ancukiewicz M et al (2004) Higher versus lower positive end-expiratory pressures in patients with the acute respiratory distress syndrome. N Engl J Med 351(4):327–336
Chatburn RL, Deem S (2007) Respiratory controversies in the critical care setting. Should weaning protocols be used with all patients who receive mechanical ventilation? Respir Care 52(5):609–619
Jouvet P (2010) Report on IntelliVent – Hamilton medical in children. Sainte-Justine Hospital, Montreal, 11 pages
Jouvet P, Farges C, Hatzakis G, Monir A, Lesage F, Dupic L et al (2007) Weaning children from mechanical ventilation with a computer-driven system (closed-loop protocol): a pilot study. Pediatr Crit Care Med 8:425–432
Jouvet P, Payen V, Gauvin F, Santschi M, Eddington A, Lacroix J (2010a) Weaning children from mechanical ventilation with a computer-driven explicit protocol: a randomized clinical trial. Am J Respir Crit Care Med 181:A3899 (abstract)
Jouvet P, Wysocki M, Emeriaud G (2010b) Safety and feasibility study of a mechanical ventilation computerized protocol: Intellivent (CloserPed): www.ClinicalTrials.gov, NCT01095406
Lellouche F, Mancebo J, Jolliet P, Roeseler J, Schortgen F, Dojat M et al (2006) A multicenter randomized trial of computer-driven protocolized weaning from mechanical ventilation. Am J Respir Crit Care Med 174(8):894–900
Lellouche F, Bouchard P, Wysocki M, Laubscher T, Novotni D, Lopez R et al (2010) Prospective randomized controlled study comparing conventional ventilation versus a fully closed-loop ventilation (IntelliVent®) in post cardiac surgery ICU patients. Am J Respir Crit Care Med 181:A6035 (abstract)
Mersmann S (ed) (2009) Instruction for use of SmartCare/PS SW 2.n. Draeger Medical, Luebeck
Otis AB, Fenn WO, Rahn H (1950) Mechanics of breathing in man. J Appl Physiol 2(11):592–607
Rose L, Presneill JJ, Johnston L, Cade JF (2008) A randomised, controlled trial of conventional versus automated weaning from mechanical ventilation using SmartCare/PS. Intensive Care Med 34(10):1788–1795
Santschi M, Gauvin F, Hatzakis G, Lacroix J, Jouvet P (2007) Acceptable respiratory physiologic limits for children during weaning from mechanical ventilation. Intensive Care Med 33(2):319–325
Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. The Acute Respiratory Distress Syndrome Network (2000) N Engl J Med 342(18):1301–1308
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2015 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Jouvet, P., Mersmann, S., Wysocki, M. (2015). Automation of Weaning in Children. In: Rimensberger, P. (eds) Pediatric and Neonatal Mechanical Ventilation. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-01219-8_61
Download citation
DOI: https://doi.org/10.1007/978-3-642-01219-8_61
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-01218-1
Online ISBN: 978-3-642-01219-8
eBook Packages: MedicineMedicine (R0)