Skip to main content

Automation of Weaning in Children

  • Chapter
  • First Online:
Pediatric and Neonatal Mechanical Ventilation

Abstract

This chapter describes the basics and the clinical experience with two explicit computerised protocols (ECP) implemented in commercialised ventilators: Smartcare/PS® by Draeger Medical (Germany) and IntelliVent® by Hamilton Medical (Switzerland). These two ECPs manage ventilation, without the need of caregivers’ intervention but under their supervision. SmartCare/PS® is an autopiloting, knowledge-based software application that provides an ECP for the automated control of pressure support ventilation. IntelliVent® is an explicit computerised protocol for the automated control of minute volume, PEEP and FiO2 in adaptive support ventilation (ASV). The main innovation of the two ECPs is the use of \( {ET}_{PCO_2} \) as a surrogate for blood gas PCO2, to decrease or increase ventilatory support. IntelliVent® also uses SpO2 to decrease or increase PEEP and FiO2. The two ECPs were studied in children during the weaning phase and the first clinical studies are promising. However, further clinical trials are needed to better assess the efficacy and tolerance of these two ECPs in children and to develop ECP that are dedicated to all ages including neonates.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 189.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 249.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  • Arnal J, Wysocki M, Demory D, Durish G, Laubscher T, Novotni D et al (2010) Prospective randomized cross-over controlled study comparing adaptive support ventilation (ASV) and a fully close loop control solution (Intellivent®) in adult ICU patients with acute respiratory failure. Am J Respir Crit Care Med 181:A3004 (abstract)

    Google Scholar 

  • Boles JM, Bion J, Connors A, Herridge M, Marsh B, Melot C et al (2007) Weaning from mechanical ventilation. Eur Respir J 29(5):1033–1056

    Article  PubMed  Google Scholar 

  • Brower RG, Lanken PN, MacIntyre N, Matthay MA, Morris A, Ancukiewicz M et al (2004) Higher versus lower positive end-expiratory pressures in patients with the acute respiratory distress syndrome. N Engl J Med 351(4):327–336

    Article  PubMed  Google Scholar 

  • Chatburn RL, Deem S (2007) Respiratory controversies in the critical care setting. Should weaning protocols be used with all patients who receive mechanical ventilation? Respir Care 52(5):609–619

    PubMed  Google Scholar 

  • Jouvet P (2010) Report on IntelliVent – Hamilton medical in children. Sainte-Justine Hospital, Montreal, 11 pages

    Google Scholar 

  • Jouvet P, Farges C, Hatzakis G, Monir A, Lesage F, Dupic L et al (2007) Weaning children from mechanical ventilation with a computer-driven system (closed-loop protocol): a pilot study. Pediatr Crit Care Med 8:425–432

    Article  PubMed  Google Scholar 

  • Jouvet P, Payen V, Gauvin F, Santschi M, Eddington A, Lacroix J (2010a) Weaning children from mechanical ventilation with a computer-driven explicit protocol: a randomized clinical trial. Am J Respir Crit Care Med 181:A3899 (abstract)

    Google Scholar 

  • Jouvet P, Wysocki M, Emeriaud G (2010b) Safety and feasibility study of a mechanical ventilation computerized protocol: Intellivent (CloserPed): www.ClinicalTrials.gov, NCT01095406

    Google Scholar 

  • Lellouche F, Mancebo J, Jolliet P, Roeseler J, Schortgen F, Dojat M et al (2006) A multicenter randomized trial of computer-driven protocolized weaning from mechanical ventilation. Am J Respir Crit Care Med 174(8):894–900

    Article  PubMed  Google Scholar 

  • Lellouche F, Bouchard P, Wysocki M, Laubscher T, Novotni D, Lopez R et al (2010) Prospective randomized controlled study comparing conventional ventilation versus a fully closed-loop ventilation (IntelliVent®) in post cardiac surgery ICU patients. Am J Respir Crit Care Med 181:A6035 (abstract)

    Google Scholar 

  • Mersmann S (ed) (2009) Instruction for use of SmartCare/PS SW 2.n. Draeger Medical, Luebeck

    Google Scholar 

  • Otis AB, Fenn WO, Rahn H (1950) Mechanics of breathing in man. J Appl Physiol 2(11):592–607

    CAS  PubMed  Google Scholar 

  • Rose L, Presneill JJ, Johnston L, Cade JF (2008) A randomised, controlled trial of conventional versus automated weaning from mechanical ventilation using SmartCare/PS. Intensive Care Med 34(10):1788–1795

    Article  PubMed  Google Scholar 

  • Santschi M, Gauvin F, Hatzakis G, Lacroix J, Jouvet P (2007) Acceptable respiratory physiologic limits for children during weaning from mechanical ventilation. Intensive Care Med 33(2):319–325

    Article  PubMed  Google Scholar 

  • Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. The Acute Respiratory Distress Syndrome Network (2000) N Engl J Med 342(18):1301–1308

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Philippe Jouvet MD, PhD .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2015 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Jouvet, P., Mersmann, S., Wysocki, M. (2015). Automation of Weaning in Children. In: Rimensberger, P. (eds) Pediatric and Neonatal Mechanical Ventilation. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-01219-8_61

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-01219-8_61

  • Published:

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-01218-1

  • Online ISBN: 978-3-642-01219-8

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics