A disconnecting switch (disconnector) is a mechanical switching device which energizes and de-energizes parts of an electrical circuit. Earthing switch is a mechanical switching device which earths parts of an electrical circuit.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 449.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 649.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  • Chai, Y.: Capacitive Current Interruption with High Voltage Air-Break Disconnecting Switches. PhD Thesis, Eindhoven University of Technology, 2012

    Google Scholar 

  • Chai, Y., Wouters, P.A.A.F., Smeets, R.P.P., Peelo, D.F.: Capacitive current interruption with air-break high voltage disconnecting switches. IEEE Trans. Power Delivery. 25(2), (2010)

    Article  Google Scholar 

  • IEC 60071-1.: Insulation Co-ordination – Part 1: Definitions, Principles and Rules

    Google Scholar 

  • IEC 60071-2.: Insulation Co-ordination – Part 2: Application Guide

    Google Scholar 

  • IEC 62271-1.: High-Voltage Switchgear and Controlgear – Part 1: Common Specifications

    Google Scholar 

  • IEC 62271-102.: High-Voltage Switchgear and Controlgear – Part 102: Alternating Current Disconnecting Switches and Earthing Switches

    Google Scholar 

  • IEC 62271-305 TR.: High-Voltage Switchgear and Controlgear – Part 305: Capacitive Current Switching Capability of Air-Break Disconnecting Switches

    Google Scholar 

  • IEC 62271-306.: High-Voltage Switchgear and Controlgear – Part 306: Guide to IEC 62271-100, IEC 62271-1 and Other IEC Standards Related to Alternating Current Circuit Breakers. This Guide Originated as CIGRÉ Technical Brochures 304 and 305

    Google Scholar 

  • National Electrical Safety Code: Grounding Rules and Parts I, II, III, IV and V. Washington, DC (1948)

    Google Scholar 

  • Peelo, D.F.: Current Interruption Using High Voltage Air-Break Disconnect Switches. PhD Thesis, Eindhoven University of Technology, 2004

    Google Scholar 

  • Peelo, D.F.: Current Interruption Transients Calculation. Wiley (2014)

    Google Scholar 

  • Peelo, D.F., Smeets, R.P.P., Kuivenhoven, S., Krone, J.G.: Capacitive Current Interruption in Atmospheric Air. Paper No. 106, CIGRÉ SC A3 and B3 Colloquium, Tokyo 2005

    Google Scholar 

  • Smeets, R., van der Sluis, L., Kapetanovic, M., Peelo, D., Janssen, A.: Switching in Electrical Transmission and Distribution Systems. Wiley (2014)

    Book  Google Scholar 

  • United States Department of Commerce, Circular of the Bureau of Standards, No. 49: Safety Rules to be Observed in the Operation of Electrical Equipment and Lines. Washington, DC (1915)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to David Peelo .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer International Publishing AG, part of Springer Nature

About this entry

Check for updates. Verify currency and authenticity via CrossMark

Cite this entry

Peelo, D. (2019). Disconnecting Switches and Earthing Switches. In: Ito, H. (eds) Switching Equipment. CIGRE Green Books. Springer, Cham. https://doi.org/10.1007/978-3-319-72538-3_9

Download citation

Publish with us

Policies and ethics