Abstract
In this work, we reports the design and technology optimization with residual stress balancing of piezo resistive silicon nitride micro cantilever stress sensors, which can be used for surface stress measurements in the liquid medium. In this context, the residual stresses of the thin films in a 600 nm thick cantilever stack (Si3N4/Poly Si/Si3N4/Au) were evaluated by curvature measurement on a test wafer to refine the balancing of the structure. In particular, the thickness of bottom silicon nitride was optimized to 300 nm to achieve the best trade-off between stress compensation and sensitivity. The cantilever bending curvature angle was calculated to be 45° and 19° with and without Au, as a top immobilization layer for the micro cantilever device. Further, finite element analysis results shows that for the low length/width ratio of cantilever, the stress sensitivity was better as compared to high aspect ratio.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Boisen, A., et al.: Design & fabrication of cantilever array biosensors. Mater. Today, 32–38 (2009)
Datar, R., et al.: Cantilever sensors: nanomechanical tools for diagnostics. MRS bulletin, 449–454 (2009)
Etayash, H., et al.: Microfluidic cantilever detects bacteria and measures their susceptibility to antibiotics in small confined volumes. Nat. Commun. 12947 (2016)
Fritz, J., et al.: Translating bimolecular recognition into nanomechanics. Science, 316–318 (2000)
Arlett, J.L., et al.: Comparative advantages of mechanical biosensors. Nat. Nanotechnol. 6, 203–215 (2011)
Wook, W.K., et al.: Novel electrical detection of label-free disease marker proteins using piezoresistive self-sensing micro-cantilevers. Biosens. Bioelectron. 1932–1938 (2005)
Rasmussen, P.A., et al.: Optimized cantilever biosensor with piezoresistive read-out, Ultramicroscopy, 371–376 (2003)
Stoney, G.: The Tension of Metallic Films Deposited by Electrolysis. Proc. R. Soc. London Ser. A, 82,172–175 (1909)
French, P.J.: Polysilicon: a versatile material for microsystems. Sens. Actuators A, 3–12 (2002)
Kanda, Y.: Piezoresistance effect of silicon. Sens. Actuators A, 83–91 (1991)
Acknowledgements
The authors wish to acknowledge the support provided by ITPAR Programme (India-Trento Programme for Advanced Research); the collaborative research programme between the Department of Science and Technology (DST) of the Indian government, the Autonomous Province of Trento (through the Trentino Cultural Institute, now Bruno Kessler Foundation) and the University of Trento for their financial support for this project. We extend our acknowledgements to the Centre for Materials and Microsystems (CMM), Fondazione Bruno Kessler, Italy for using the design and micro fabrication facility of MEMS cantilever devices.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer International Publishing AG
About this paper
Cite this paper
Kandpal, M., Adami, A., Giacomozzi, F., Zen, M., Rao, V.R., Lorenzelli, L. (2018). Theoretical and Experimental Analysis of Residual Stress Mitigation in Piezoresistive Silicon Nitride Cantilever. In: Leone, A., Forleo, A., Francioso, L., Capone, S., Siciliano, P., Di Natale, C. (eds) Sensors and Microsystems. AISEM 2017. Lecture Notes in Electrical Engineering, vol 457. Springer, Cham. https://doi.org/10.1007/978-3-319-66802-4_30
Download citation
DOI: https://doi.org/10.1007/978-3-319-66802-4_30
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-66801-7
Online ISBN: 978-3-319-66802-4
eBook Packages: EngineeringEngineering (R0)