Reducing the energy consumption of large scale distributed systems (high performance computing centers, networks, datacenters) is a mandatory step to address, in order to build a sustainable digital society. Since more than a decade, several technological solutions have been made available by system designers to help reducing power, like shutdown and slowdown approaches. The first and most explored solution consists in shutting down and waking up some resources depending on platform usage. In this paper, the question on how resource providers and managers can be helped to validate their constraints while reducing the energy consumption using only the shutdown and wake-up of large amount of resources is addressed.

Resource providers and managers can be human who are responsible of the administration of large supercomputers, but they can also be software components that deal with resources (schedulers, resource management frameworks, etc.). Nowadays, hardware components of a datacenter or supercomputer (servers, network switches, data storage, etc.) are not yet energy proportional. In fact, the static part (i.e., the part that does not vary with workload) of the energy consumed for example by computing units, represents a high part of the overall energy consumed by the node. Therefore, shutting unused nodes or routers, that are idle and not expected to be used in a predicted duration, could lead to non negligible energy savings. This paper focuses on shutting down and waking up any kind of resources like servers, network devices, memory banks, cores, etc. For clarity’s sake, here, the proposed models and validations focus on servers (called nodes).

Off-the-shelf software eco-systems are nowadays integrating (mainly basic) shutdown policies. Data center resource managers propose techniques or hooks to configure such capabilities. For example, Slurm [16], an open-source cluster management system, introduces a SuspendTime Footnote 1 that represents the minimum idle time after which it allows the node to be switched off. Then, the resource manager is responsible for deciding when to switch on and off servers. It takes decisions either based on pre-determined policy [16], on workload predictions [8], on queuing models [5] or on control theory approach [15].

Overall, shutdown seems to be an interesting leverage to save energy (referred to as OnOff leverage). But this technique cannot be applied at large scale if no constraint is respected on the target system. This is especially true if the resource providers take into account several types of constraints, such as the cost of shutdown and wake-up (in time and energy), or power-capping constraints imposed to the whole system. In particular, shutting down too many nodes could cause the power consumption to be under the minimum power capping decided with the electricity provider. Likewise, if too many nodes are waked up, and if providers take into account the energy consumed during shutdown and wake-up sequences (which is far from being free), limits fixed by the electricity provider can be greatly exceeded. If providers do not take into account such constraints, they can put into danger machines composing the studied computing facility.

In this paper, we propose several models of shutdown that can be used under actual and future supercomputer constraints, and that takes into account the impact of shutting down and waking up nodes (time, power and energy) and the Idle and Off states observed after such actions as they impact the power usage. Our formalization allows for a mono or combined usage of models in order to help resource managers and providers respect several constraints at the same time. Several shutdown models that can be handled by resource providers and that deal with infrastructure constraints are explored:

  • The basic models allow comparisons with several related works where shutting down and waking up nodes can either be free and immediate, or not allowed.

  • The sequence-aware models account for the cost of shutting down or waking up nodes, in terms of time or energy.

  • The power-capping models aim at respecting power capping requirements.

The models are used as follows: knowing that there is an idle interval of length \(T_{\text {gap}}\) on a given node, the model decides whether the node should be shut down, given the enforced constraints.

The paper is organized as follows. Section 2 presents the modeling of the various shutdown (OnOff) policies for basic models, sequence-aware models, and finally models dealing with power-capping. It also deals with the usage and combination of these models. The experimental setup is described in Sect. 3 and experimental results are analyzed in Sect. 4. Section 5 presents related work on shutdown techniques for large scale systems. Section 6 concludes and presents future work.

2 Modeling Shutdown Policies

This section presents our characterization of the impact of shutting down and waking up a node in terms of time and power consumption. It also introduces models acting on the OnOff leverage.

2.1 Model Inputs

To monitor nodes’ wake-up and shutdown sequences, an external power monitoring allowing us to trace power consumption of nodes is used. It has a rate of one power value per second. The sequences have been monitored to detect when every event happened. For the wake-up sequence, unfortunately, no information could be extracted between BIOS (Basic Input Output System) bootstrap and GRUB (Grand Unified Bootloader) loading. The first monitorable event in this sequence is the Kernel launch; this is displayed on Fig. 1, which shows how the power evolves with time during a monitored boot sequence on a node. The time where kernel starts has been recovered with the dmesg tool (which is a logging of what happened during the launch of the kernel). The INIT monitoring is made by modifying the runlevel scripts.

These monitored profiles are modeled by a sequence for each node. For node i, \(Seq_i = \{ (t_0; AvrgP_0), \dots , (t_n; AvrgP_n)\}\) is the set of timestamps and average power consumption measurements of a wake-up (or Off\(\rightarrow \)On sequence) or shutdown (or On\(\rightarrow \)Off sequence), where \(t_0\) and \(t_n\) represent the starting and ending time respectively of sequence Seq on node i. The length of the sequence is therefore \(t_n-t_0\), and at time-step \(t_k\) (\(1\le k \le n\)), \(AvrgP_k\) is the average power consumption of node i.

Fig. 1.
figure 1

Monitored boot sequence of a node running Linux: BIOS-MBR-GRUB period in red; Kernel in green; INIT in gray. (Color figure online)

2.2 Model Definitions

Basic Models. Two basic models are used by most papers in the literature: either the nodes are never shut down (No-OnOff model), or there is no cost (time, energy, power) to wake up or shutdown a node (LB-ZeroCost-OnOff model: Lower-Bound Zero-Cost OnOff Model), making it very simple to shutdown a node (but very far from reality). In this context, the node consumes nothing when executing an On\(\rightarrow \)Off or Off\(\rightarrow \)On sequence. Thus, there is no cost nor time spent to switch state, and no power peak observed during the sequence. In this context, no influence could be derived from waking up or shutting down nodes. This LB-ZeroCost-OnOff model therefore provides a theoretical upper bound on the gains that can be achieved by shutting down nodes.

Sequence-Aware Models. The sequence-aware models make sure that the sequence observed on a node or set of nodes during On\(\rightarrow \)Off or Off\(\rightarrow \)On sequences fits in time or are beneficial in energy. Therefore, information for every node composing the studied case needs to be recorded, in particular a record of the Off\(\rightarrow \)On and On\(\rightarrow \)Off sequences.

Time Constrained. The first model, Seq-Aw-T (Sequence-Aware-Time), checks whether there is enough time to perform an On\(\rightarrow \)Off sequence followed by an Off\(\rightarrow \)On sequence on a node, given the available time when the node is idle. Let \(T_{\text {gap}}\) be the size of the “gap”, i.e., the interval of idle time of the node. Then, Seq-Aw-T will allow the addition of sequences in this time slot if and only if \(T_{\text {OnOff}} + T_{\text {OffOn}} \le T_{\text {gap}} \), where \(T_{\text {OnOff}} \) (resp. \(T_{\text {OffOn}}\)) is the time spent by the node during an On\(\rightarrow \)Off (resp. Off\(\rightarrow \)On) sequence.

Energy Constrained. The Seq-Aw-E model (Sequence-Aware-Energy) further refines Seq-Aw-T by checking whether changing the state of the node is beneficial in terms of energy. The minimum time \(T_s\) of the gap is now further constrained by the energy savings:

$$\begin{aligned} T_s = \max \left( T_{\text {OnOff}} + T_{\text {OffOn}}, \frac{E_{\text {OnOff}} + E_{\text {OffOn}}- P_{\text {off}} (T_{\text {OnOff}} + T_{\text {OffOn}})}{P_{\text {idle}}- P_{\text {off}}}\right) , \end{aligned}$$

where:

  • \(P_{\text {idle}}\) is the power consumption when the node is in the Idle state (unused, but powered on);

  • \(P_{\text {off}} \) is the power consumption when the node is switched off (typically not null and lower than \(P_{\text {idle}} \));

  • \(E_{\text {OnOff}} \) is the energy consumed during the On\(\rightarrow \)Off sequence;

  • \(E_{\text {OffOn}} \) is the energy consumed during the Off\(\rightarrow \)On sequence.

The first term states, as for Seq-Aw-T, that at least a time \(T_{\text {OnOff}}\) + \(T_{\text {OffOn}}\) is needed to shutdown the node (and to wake it up) during the idle interval. The second term ensures that there will be gains in energy: the energy saved by running at \(P_{\text {off}}\) rather than \(P_{\text {idle}}\) is \(T_s(P_{\text {idle}}-P_{\text {off}})\) during the interval, but the additional energy due to the On\(\rightarrow \)Off and Off\(\rightarrow \)On sequences is \(E_{\text {OnOff}} + E_{\text {OffOn}}- P_{\text {off}} (T_{\text {OnOff}} + T_{\text {OffOn}})\). Therefore, if \(T_{\text {gap}} > T_s \), then it is beneficial to shutdown (at the beginning of the gap) and to wake up (at the end of the gap) the node, in terms of energy consumption.

Power-Capping-Aware Models. The Power-Cap model (Power-Capping-Aware) aims at maintaining an average power budget and guaranteeing minimal or maximal electrical power consumption. Indeed, shutting down and waking up components could lead to hard power-capping disruptions. Such actions energetically stress the node, whether it is in an upper or lower way. Here, information about the power capping that should be respected is provided.

A minimum power capping (\(PC\_Min\)) represents a constraint set by the electrical provider, and is defined by providing a lower bound on power. A maximum power capping (\(PC\_Max\)) represents power limit fixed by the electrical provider, and it is defined by an upper limit on power. These minimum and maximum power capping values may be a function of the time, i.e., the requirements may change in time.

We introduce the function PowerSum(Xt), which returns the sum of the power consumed by nodes in set X at time-step t. We denote by ALL the set of all nodes. Nodes in X can be shut down or waked up only if \(PowerSum(ALL,t) \ge PC\_Min\) and \(PowerSum(ALL) \le PC\_Max\) at all time during the sequence.

2.3 Model Usages

Several models have been derived, assuming that local knowledge about the node reservations is available, i.e., the current state of each node: On (Working or Idle) or Off. At current time-step \(T_c \), a model aims at deciding whether this node can be shut down and then waked up, while respecting the constraints of the system. If the node is neither in a Working or Off state, it is in an Idle interval of length \(T_{\text {gap}}\). Therefore, an entity giving advice on changing the state of a node (or set of nodes) is provided, making sure that the overall system responds to the described constraints.

3 Experimental Setup

To instantiate our models in various configurations, we developed a simulator capable of replaying a real datacenter trace, with real node and job calibrations (time, power, energy). Grid’5000 [1], a large-scale and versatile testbed for experiment-driven research in all areas of computer science, was used as a testbed. Grid’5000 deploys clusters linked with dedicated high performance networks in several cities in France (Lille, Nancy, Sophia, Lyon, Nantes, Rennes, Grenoble). On the Lyon site, the energy consumption of every node from all available clusters (Orion, Taurus, Sagittaire) is monitored through a dedicated wattmeter, exposing one power measurement per second with a 0.125 W accuracy. Therefore, detailed traces concerning the energy consumption of jobs at any time step are available. An average power consumption of each job was obtained. Thanks to these traces, realistic replays of jobs with their corresponding energy consumption is performed. Taurus nodes were monitored to calibrate in time, energy and power the Off\(\rightarrow \)On and On\(\rightarrow \)Off sequences, as explained in Sect. 2 (see Table 1).

Table 1. Calibration nodes’ characteristics and energy parameters for On\(\rightarrow \)Off and Off\(\rightarrow \)On sequences (average on 50 experimental measurements).

For our evaluation, two real workload traces of the Grid’5000 Lyon site were extracted. Traces only contain nodes that received jobs during the chosen period to avoid doping of the energy saving results with nodes that will potentially always be shutdown. The first one runs from October 24, 2016 at 7 pm to November 1, 2016 at 8 am, thus representing approximately one week of resource utilization on this site. During this period, the number of used nodes is 76. The second one runs from October 29, 2016 at 7 pm to December 1, 2016 at 3 am, thus representing approximately one month of resource utilization. The number of used nodes is 69. Nodes are considered homogeneous concerning the \(P_{\text {idle}} \), \(P_{\text {off}} \) characteristics, Off\(\rightarrow \)On and On\(\rightarrow \)Off sequences. This study is focused on shutting down nodes, scheduled jobs are considered fixed. Moreover, we only add sequences if possible, thus not impacting nor overlaying scheduled jobs. For the week trace, there are 1,768 jobs with an average power consumption of 167.5 Watts and an average job size of 13,776.96 s (approximately four hours). For the month trace, there are 5,505 jobs with an average power consumption of 166.5 Watts and an average job size of 14,203.42 s (approximately four hours). Yet, these traces exhibit high workload variations as shown on Figs. 2 and 3, where the upper curve corresponds to the No-OnOff model.

4 Experimental Validation

This section presents the simulation results for the proposed setup as proposed in Sect. 3. All graphs represent a trace replay of the application of one or multiple combined models of Sect. 2. Table 2 presents the energy consumption in Joules of all models in the figures included in this section. This section presents results of the simulator on the extracted traces with calibration of Taurus nodes while applying previously defined models. The first trace, which spreads over one week, will be used to extensively study behavior of models. The second trace, over one month, will validate observations and model tendencies at a larger scale.

For the experiments involving Power-Cap, Seq-Aw-T is always combined with this model to ensure that the node is in the On state when a scheduled job starts. Shutting down a node is allowed only when it can be waked up before the end of the idle time interval, to ensure that no job is delayed.

Table 2. Trace replay’s energy consumption (in Joules), number of added double sequences (On\(\rightarrow \)Off and Off\(\rightarrow \)On), and percentage of energy saved compared to No-OnOff replay.

4.1 Sequence-Aware Models: Seq-Aw-T and Seq-Aw-E

Figures 2 and 3 show results of the different models, namely No-OnOff, Seq-Aw-T, Seq-Aw-E, and LB-ZeroCost-OnOff on, respectively, one week and one month traces. Between the two sequence-aware models, minor differences can be witnessed on the complete replay. For example on Fig. 2, for October 31 at 4:40 am, Seq-Aw-T allows more Off\(\rightarrow \)On sequences to be scheduled. Both of these models lead to major energy savings, respectively 34.00% and 39.9% of energy savings on the one week trace compared to No-OnOff, as shown in Table 2. In comparison with the No-OnOff trace replay, major power peaks are witnessed because of the application of these models. For instance, in the one week trace, for October 31 at 12:00 pm, after a peak of work around 12,000 W, a very low peak is witnessed under 1,000 W. Such a behavior could be witnessed in an amplified way on Fig. 3 for instance around November 12, November 3, and November 21. Such behaviors could lead to abrupt thermal changes and thus to hot and cool spots, so to possible deterioration of the nodes.

LB-ZeroCost-OnOff, the model with immediate On\(\rightarrow \)Off with zero cost is also presented for comparison. There is no significant difference in energy consumption observed when the cost of On\(\rightarrow \)Off and Off\(\rightarrow \)On sections are accurately described. However, the number of On\(\rightarrow \)Off that are effectively triggered is significantly lower, implying that LB-ZeroCost-OnOff allows the addition of sequences when \(T_{\text {gap}} \) is smaller that \(T_{\text {OnOff}} + T_{\text {OffOn}} \).

Fig. 2.
figure 2

Replay for a week of Grid’5000 trace with No-OnOff (NO) and with Seq-Aw-T (SAT), Seq-Aw-E (SAE), LB-ZeroCost-OnOff (LB) models.

Fig. 3.
figure 3

Replay for a month of Grid’5000 trace with No-OnOff (NO) and with Seq-Aw-T (SAT), Seq-Aw-E (SAE), LB-ZeroCost-OnOff (LB) models.

4.2 Power-Capping Model

Next, a focus on the Power-Cap model is made. A maximum and a minimum power cap is set throughout the simulation. Modulation of the minimum power cap to see how it acts with the trace replay is then simulated. Recall that since only the OnOff leverage is evaluated, scheduled jobs are fixed. Therefore, maximum power cap does not vary because it highly depends on jobs and also because the difference between \(P_{\text {idle}} \) and \(P_{\text {off}} \) is more important than the difference between the peaks witnessed during the Off\(\rightarrow \)On or On\(\rightarrow \)Off sequences and \(P_{\text {idle}} \).

Figure 4 shows results of No-OnOff, Seq-Aw-T and Power-Cap with various \(PC\_Min\) scenarios (2000, 4000 and 6000) during the one week trace. Even with the highest minimum power cap, here 6,000 W, important energy savings (around 16.82 % compared to No-OnOff) are made. The stratified power usage for every respected power cap was expected. In fact, a lower power cap permits more sequences to be scheduled and thus, more energy savings. The lowest cap constraint (2,000 W) shows that a minimum power capping could be always respected and would still have a close to minimum consumption. Finally, Fig. 5 shows results for larger scale replay (one month) on No-OnOff, Seq-Aw-T and Power-Cap with 4,000 as \(PC\_Min\), and leads to the same conclusions.

Fig. 4.
figure 4

Replay for a week of Grid’5000 trace with No-OnOff (NO) and with Power-Cap (with \(PC\_Min=2000, 4000, 6000\)), Seq-Aw-T (SAT) models.

Fig. 5.
figure 5

Replay for a month of Grid’5000 trace with No-OnOff (NO) and with Power-Cap (with \(PC\_Min=4000\)), Seq-Aw-T (SAT) models.

5 Related Work

Pioneering work on studying the energy-related impacts of shutdown techniques started in 2001 [2, 11]. These early efforts did not consider any transition cost for switching between Idle and Off states, but they nonetheless showed the potential impact of such techniques. Yet, aggressive shutdown policies are not always the best solution to save energy [9].

Demaine et al. examine the power minimization problem where the objective is to minimize the total transition costs plus the total time spent in the active state [3]. They develop a \((1 + 2 \alpha )\)-approximation algorithm, with \(\alpha \) the transition cost. However, the parameters considered for this transition cost highly vary across the literature. Gandhi et al. take into account the energy cost of waking up servers (no shutting down cost as it is estimated to be negligible in comparison with the waking-up cost) [5]. This energy cost is assumed to be equal to the transition time multiplied by the power consumption while in the Idle state. Lin et al. take into account the energy used for the transition, the delay in migrating connections or data, the increased wear-and-tear on the servers, and the risk associated with server toggling [7]. We go one step beyond and carefully assess the cost of shutting down or waking up a node, in terms of time, power and energy.

Moreover, supporting shutdown and wake-up of large amount of resources can be risky as it impacts the whole infrastructure of supercomputers, such as the cooling system [18]. Shutdown techniques can also be used for limiting the dark silicon effect, i.e., the under-utilization of the device integration capacity due to power and temperature effects [4]. This issue has lead to the introduction of user-specified, dynamic, hardware-enforced processor power bounds, as for the Intel’s Sandy Bridge family of processors for instance [13]. At a data center level, it translates into power budgeting, where the total power budget is partitioned among the cooling and computing units, and where the cooling power has to be sufficient to extract the heat of the computing power. Given the computing power budget, Zhan and Reda propose an optimal computing budgeting technique based on knapsack-solving algorithms to determine the power caps for the individual servers [17].

Shutdown policies are often combined with consolidation algorithms that gather the load on a restricted number of servers to favor the shutdown of the others. Employing either reactive or proactive scheduling options [6, 10], consolidation algorithms increase the energy gains brought by shutdown techniques at a cost of a trade-off with performance [14]. The rich diversity in power management techniques and levers can lead to substantial issues if they are not coordinated at the data center level [12]. In this paper, shutdown policies (i.e., when to shutdown) are studied, without combining them to scheduling algorithms and consolidation approaches in order to evaluate the impacts of such policies without interfering with the workload of real platforms and with the users’ expected performance.

6 Conclusion

In this paper, the OnOff leverage is explored as a technique to save energy on large scale computing systems. While it is often assumed that nodes can change state at no cost, realistic scenarios are explored where several constraints (time and energy of changing the state of a node, global power capping on the platform) may prevent us from shutting down a node at a given time. This paper presents a formal definition of such models, targeting various scenarios on selected architectures.

A possible application of these models, either alone or combined, is provided through a set of simulations on real workload traces, showing the gain in energy that can be achieved, given the constraints on the platform, and providing clear guidelines about when a node can change state. Overall, the gain of the non-realistic model, where nodes are instantaneously shutdown during an idle period, is very small over the sequence-aware model, that shutdowns a node only if there is time to wake it up again before the next computation (Seq-Aw-T), and accounts for the power consumption during the Off\(\rightarrow \)On and On\(\rightarrow \)Off sequences (Seq-Aw-E). On top of previous models, power-capping constraints (Power-Cap) could be enforced, thus reducing the number of added On-Off sequences, and hence leading to losses in energy, but fully respecting the imposed constraints.

We plan to further add several models by considering for example a cooling-aware model that accounts for the system temperature in order to avoid abrupt thermal changes (and thus hot and cool spots), provoked by changing the state of a large number of nodes. We also plan to deeply analyze combinations of shutdown models in order to jointly take into account more realistic constraints imposed to supercomputers.