Skip to main content

Application of Gamma Criteria for FIF Therapy for Wide Breast Size Range

  • Conference paper
  • First Online:
XIV Mediterranean Conference on Medical and Biological Engineering and Computing 2016

Part of the book series: IFMBE Proceedings ((IFMBE,volume 57))

  • 87 Accesses

Abstract

Evolution of complex planning techniques, such as IMRT and VMAT, has set high requirements for labor intensive quality assurance procedures. For the evaluation of intensity modulated radiotherapy plan, gamma evaluation method is widely used for accurate quantitative comparison of measured dose distribution and desired dose distribution from treatment planning system (TPS). Field – in – field (FIF) 3D conformal planning technique, widely used now in breast cancer treatment. FIF is the forward planning technique, where one or more subfields are introduced to achieve higher dose homogeneity in treatment volume. Since FIF is based on the same intensity modulation principles as IMRT, it is possible to use gamma evaluation method for FIF breast fields. The aim of the present paper is to determine whether gamma criteria pass/fail rate is treatment volume dependent. For this study, four patients with different breast volumes (1115.4 cc, 1716.46 cc, 2531.65 cc and 3276.27 cc) were examined. Calculation was performed using treatment planning system XiO, where reference fields were exported to phantom and artificial shifts of the field in step of 1 mm were introduced. The maximum shift for one direction (lateral or longitudinal) does not exceeded 1 cm. The FIF segments were shifted relative to base fields in eight directions: lateral “+”, lateral “-”, longitudinal “+”, longitudinal “-”. All uncertainties related to LINAC and MLC were excluded because of TPS versus TPS comparison method. For acceptance criteria ⇆DM=3% dose-difference and ⇆dM=3 mm distance-to-agreement (DTA) were used and 95% of all pixels should be within this criterion. Results demonstrates, that, independently on the breast size, gamma criterion failed to detect internal field displacement up to 5 mm

The original version of this chapter was inadvertently published with an incorrect chapter pagination 764–767 and DOI 10.1007/978-3-319-32703-7_149. The page range and the DOI has been re-assigned. The correct page range is 770–773 and the DOI is 10.1007/978-3-319-32703-7_150. The erratum to this chapter is available at DOI: 10.1007/978-3-319-32703-7_260

An erratum to this chapter can be found at http://dx.doi.org/10.1007/978-3-319-32703-7_260

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. A.G. Morganti, S.Cilla, “Forward planned intensity modulated it useful? When?”, Journal of Applied Clinical Medical Physics, Vol 12, No 2, 2011.

    Google Scholar 

  2. G. Yabas, C. Yavas, H. Acar “Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer”, Iranian Journal of Radiation Research, 10(3-4), p. 131 – 138, 2012.

    Google Scholar 

  3. S.X Chang, J.P. Gibbons “Clinical implementation of non-physical wedges”, AAPM refresher course, 1999, p. 13

    Google Scholar 

  4. T. Depuydt, A. Van Esch & D. P. Huyskens, A quantitative evaluation of IMRT dose distributions: refinement and clinical assessment of the gamma evaluation. Radiotherapy & Oncology, 62(3), p. 309-319, 2002.

    Google Scholar 

  5. T. Pawlicki, P. Dunscombe, A.J. Mundt, P. Scallieat “Quality and Safety in radiotherapy”, CRC Press, 2010, 644 p.

    Google Scholar 

  6. J.W. Lee, S. Hong, K.S. Choi, “Performance evaluation of field-in- field technique for tangential breast irradiation”, Jpn J.Clin Oncol 2008; 38(2), p. 158-163.

    Google Scholar 

  7. A. Bernans, A. Katashev “Sensitivity evaluation methods for gamma criterion”, Proceedings of 56th International Scientific Conference of the Riga Technical University, RTU, Riga, 2015, in press

    Google Scholar 

  8. D.A. Low, W.B. Harms, S. Mutic, J.A. Prudy “A technique for the quantitative evaluation of dose distributions” Medical Physics, 1998, 25 (5), p 656 – 660.

    Google Scholar 

  9. Fournier-Bidoz, N., Kirova, Y. M., Campana, F., Dendale, R., & Fourquet, A. (2012). Simplified field-in-field technique for a large- scale implementation in breast radiation treatment. Medical Dosimetry, 37(2), p 131–137.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Alexei Katashev .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2016 Springer International Publishing Switzerland

About this paper

Cite this paper

Bernans, A., Katashev, A. (2016). Application of Gamma Criteria for FIF Therapy for Wide Breast Size Range. In: Kyriacou, E., Christofides, S., Pattichis, C. (eds) XIV Mediterranean Conference on Medical and Biological Engineering and Computing 2016. IFMBE Proceedings, vol 57. Springer, Cham. https://doi.org/10.1007/978-3-319-32703-7_150

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-32703-7_150

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-32701-3

  • Online ISBN: 978-3-319-32703-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics