Abstract
The basic formula for determining the of a Pelton turbine is Eq. (2.40). This equation has been taken over directly from the equation of frictionless flow in a linearly translating bucket. It only takes into consideration the exit swirling loss. Since the efficiency is calculated there for a constant peripheral speed coefficient (k m) and in effect each water particle has its individual form in the interaction with the bucket, the calculation for a constant peripheral speed coefficient is only an approximation. Its comparison with the computational results from the so-called jet layer method (Sect. 6.2.2) showed a small difference of only about 0.2 % (Fig. 9.5).