Skip to main content

Incision

  • Chapter
  • First Online:
Manual Small Incision Cataract Surgery

Abstract

The ultimate result of a cataract surgery is dependent on the optimal performance of each step of the procedure. The success of each step in turn depends on the steps preceding it. Wound construction in MSICS can be considered as a rate-limiting step of cataract surgery. An error in this step can spiral into the subsequent steps and also weigh adversely in the immediate post-op period.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.00
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

Notes

  1. 1.

    Gives enough conjunctival surface to incise

    • The conjunctiva and tenons will be a safe distance away from the scleral surface.

    • Tangential inflicted cuts without proper vertical conjunctival traction can result inadvertent scleral injury.

  2. 2.
    •  Presence of tenons may cause irregular incision of variable depth along its extent. It also prevents smooth movement of the tunnel blade, which predisposes to septae within the tunnel.

    • Obscurance caused by overhanging limbal epithelium and remnant tenons may also lead to incorrect depth assessment while tunneling.

Acknowledgments

Dr.Sathish Devarajan who has contributed all the diagrams in this chapter.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Aravind Haripriya .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2016 Springer International Publishing Switzerland

About this chapter

Cite this chapter

Haripriya, A., Singh, T.P., Nayak, D.P. (2016). Incision. In: Henderson, B. (eds) Manual Small Incision Cataract Surgery. Springer, Cham. https://doi.org/10.1007/978-3-319-24666-6_5

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-24666-6_5

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-24664-2

  • Online ISBN: 978-3-319-24666-6

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics