Evaluation of the eye lens dose according to patient setup errors in pediatric head CT examination

  • Conference paper
World Congress on Medical Physics and Biomedical Engineering, June 7-12, 2015, Toronto, Canada

Part of the book series: IFMBE Proceedings ((IFMBE,volume 51))

  • 180 Accesses

Abstract

According to the 2011 ICRP statement, the threshold in absorbed dose for the lens of the eye is now considered to be 0.5 Gy. Therefore, it is important to keep the eye lens doses during head computed tomography examination as low as reasonably achievable. In this study, the two lenses and the occiput doses associated with patient setup errors and head size were evaluated using phantoms developed for pediatric patients. The phantoms were made using flexible acrylic sheets in a cylindrical shape [diameters of 6 (premature baby), 8 (neonate), 10 (infant), and 12 cm (child)] and placed on the end of the CT bed. The bed position was raised from the center for each phantom size. The two lenses and the occiput doses at each setup were measured using radiochromic film. By raising the bed position, the two lenses doses decreased at all phantom sizes. However, the occiput doses changed in a complex manner according to the phantom size. In this study, decreasing the distance from the lens to the X-ray tube (i.e. raising the bed position) is an effective way to reduce the absorbed dose of the lens. However, when the occiput was positioned at the center of the gantry aperture, the occiput dose peaked in all phantom sizes. In addition, the results indicated a complex dose distribution in pediatric head CT when taking into account the bed position (patient setup errors) and phantom sizes. Furthermore, beam slice width and pitch are important factor in determining the maximum absorbed dose. To keep radiation doses during CT examination as low as reasonably achievable, it is important to clarify the influence of CT scanning settings on CT dose.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2015 Springer International Publishing Switzerland

About this paper

Cite this paper

Gotanda, R. et al. (2015). Evaluation of the eye lens dose according to patient setup errors in pediatric head CT examination. In: Jaffray, D. (eds) World Congress on Medical Physics and Biomedical Engineering, June 7-12, 2015, Toronto, Canada. IFMBE Proceedings, vol 51. Springer, Cham. https://doi.org/10.1007/978-3-319-19387-8_177

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-19387-8_177

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-19386-1

  • Online ISBN: 978-3-319-19387-8

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics