Part of the book series: IFMBE Proceedings ((IFMBE,volume 51))

  • 130 Accesses

Abstract

Mammography is considered the most suitable technique for the identification, tracking and staging of breast diseases, especially cancer. However, the use of ionizing radia-tion carries a risk of inducing cancer in this kind of breast imaging procedure. In this way, it is important to know the dose distribution in typical mammography techniques. The aim of this work was to estimate the dose distributions in dif-ferent positions parallel to the image plan and different depths of a tissue equivalent phantom using LiF thermoluminescent dosimeters (TLD). LiF TLDs pellets were positioned on the xy plan on a phantom BR12 at different depths. The set was irra-diated in a GE Senographe DS System for a maximum field size. The dosimeters were irradiated using a Mo/Mo an-ode/filter combination, 100 mAs, and different X-ray tube voltages (25, 28, 30 and 32 kVp). It was also used a fixed X-ray tube voltage (28 kVp), 100 mAs, and different anode/filter combinations (Mo/Mo, Mo/Rh and Rh/Rh). Dose variation in the y direction was more significant than in the x direction. It were observed variations up to 8% and 28.2% in x and y direc-tions respectively. For the tube voltage 28 kVp, the maximum dose in the phantom surface in the y-axis was 16(1) mGy for Mo/Mo, and 15.0 (9) mGy for Mo/Rh and 12.8(6) for Rh/Rh.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2015 Springer International Publishing Switzerland

About this paper

Cite this paper

Santos, J.C., Tomal, A., Furquim, T., Costa, P.R. (2015). Estimation of dose distributions in mammography into a tissue equivalent phan-tom. In: Jaffray, D. (eds) World Congress on Medical Physics and Biomedical Engineering, June 7-12, 2015, Toronto, Canada. IFMBE Proceedings, vol 51. Springer, Cham. https://doi.org/10.1007/978-3-319-19387-8_170

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-19387-8_170

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-19386-1

  • Online ISBN: 978-3-319-19387-8

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics