Abstract
The performance of induction motors under different voltage unbalance levels and different loading is investigated in this chapter. The stator/rotor currents, torque and additional power losses are determined for each voltage unbalance value. The levels range from low level to severe situations to assess the ability of the induction motor to withstand different stress levels. A MATLAB/SIMULINK implementation is done to produce the currents, torque and power losses.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Abbreviations
- CVUF:
-
Complex voltage unbalance factor
- IEC:
-
International Electromechanical Commission
- IEEE:
-
Institute of Electrical Engineering and Electronics
- LVUF:
-
Line voltage unbalance factor
- NEMA:
-
National Electrical Manufacturers Association
- PVU:
-
Percent voltage unbalance
- PVUR:
-
Phase voltage unbalance rate
- VUF:
-
Voltage unbalance factor
References
Refoufi L, Bentarzi H, Dekhandji FZ (2006) New approach of induction motor performance study under different voltage unbalance conditions. WSEAS Trans Power Syst 1(8):1519–1525
Faiz J, Ebrahimpour H, Pillay P (2004) Influence of unbalanced voltage on the steady-state performance of a three-phase squirrel-cage induction motor. IEEE Trans Energy Convert 19(4):657–662
Lee CY (1999) Effects of unbalanced voltage on operation performance of a three-phase induction motor. IEEE Trans Energy Convert 14(2):202–208
Pillay P (2002) Derating of induction motors operating with a combination of unbalanced voltages and over and under voltages. IEEE Trans Energy Convert 17(4):485–491
Kersting WH, Phillips WH (1977) Phase frame analysis effects of voltage unbalance on induction machines. IEEE Trans Indust Appl 33(2):415–420
Gafford BN, Duesterhoef WC, Mosher CC (1959) Heating of induction motors on unbalanced voltages. AIEE Trans Power Apparat Syst 78:282–297
Quispe E, Gonzalez G, Aguado J (2004) Influence of unbalance and waveform voltage on the performance characteristics of three-phase induction motors. In: Proceedings of international conference on renewable energy and power quality applications, Barcelona, España, ISBN 8460798870
IEC (2002) Rotating electrical machines, part 26: effects of unbalanced voltages on the performance of induction motors, IEC Standard 60034-26. IEC, Geneva
NEMA (1993) Motors and generators, ANSI/NEMA Standard MG1-1993. NEMA, Rosslyn, VA
Wang YJ (2001) Analysis of effects of three-phase voltage unbalance on induction motors with emphasis on the angle of the complex voltage unbalance factor. IEEE Trans Energy Convert 16(3):2001.
Wang YJ (2000) An analytical study on steady-state performance of an induction motor connected to unbalanced three-phase voltage. In: IEEE power engineering society winter meeting, Singapore, 23–27 Jan 2000
Pierrat L, Meyer JP (1987) Unbalance factor, it is as simple as ABC. Rev Gén Électricité 6:18–26
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2015 Springer International Publishing Switzerland
About this chapter
Cite this chapter
Dekhandji, F.Z., Refoufi, L. (2015). Performance of Induction Motor Under the Effect of Voltage Unbalance with Loading Consideration. In: Dincer, I., Colpan, C., Kizilkan, O., Ezan, M. (eds) Progress in Clean Energy, Volume 2. Springer, Cham. https://doi.org/10.1007/978-3-319-17031-2_49
Download citation
DOI: https://doi.org/10.1007/978-3-319-17031-2_49
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-17030-5
Online ISBN: 978-3-319-17031-2
eBook Packages: EnergyEnergy (R0)