Skip to main content

Unconventional Double R/U Converter for Measurement of Two Quantities by a Single Differential Sensor

  • Conference paper
Progress in Automation, Robotics and Measuring Techniques

Part of the book series: Advances in Intelligent Systems and Computing ((AISC,volume 352))

  • 1267 Accesses

Abstract

This paper describes an original four arm single mesh resistance circuit. It has the similar structure as the bridge circuit but is unconventionally supplied by the current source which is switched over between opposite arms. The two output signals of this circuit are sums of two voltages obtained after switching on each bridge diagonal. The processing of this signals allows to find two measured variables which differently influencing arm resistances. The two dimensional (2D) converter of the resistance changes to voltages based on this input circuit is build. It is described in detail and its dynamic properties are examined. The achieved results confirm that this unconventional signal conditioning circuit can be successfully used in continues measurements of two parameters, e.g. two geometrical components of the strain or the strain and temperature by a single differential sensor.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Walendziuk, W.: Measurement Uncertainty Analysis of the Strain Gauge Based Stabilographic Platform. Acta Mechanica et Automatica (8, part. 2), 74–78 (2014)

    Google Scholar 

  2. Walendziuk, W., Idźkowski, A.: Portable acquisition system for domiciliary uroflowmetry. Journal of Vibroengineering, (11, part. 3), 592–596 (2009)

    Google Scholar 

  3. Cappa, P., Marinozzi, F., Sciuto, S.A.: A novel method for the simultaneous measurement of temperature and strain using a three-wire connection. Measurement Science and Technology 12(4), 502–506 (2001)

    Article  Google Scholar 

  4. Pedersen, C., Jespersen, S.T., Krog, J.P., Christensen, C., Thomsen, E.V.: Combined differential and static pressure sensor based on a double-bridged structure. IEEE Sensors Journal 5(3), 446–454 (2005)

    Article  Google Scholar 

  5. Warsza, Z.L.: Bridges supplied by two current sources – new tool for impedance measurements and signal conditioning. In: Proc. of IMEKO-TC 7 Symposium, pp. 231–236. Cracow University of Technology (June 2002)

    Google Scholar 

  6. Warsza, Z.L.: Four-terminal (4T) immittance circuits in multivariable measurements. Monograph. Industrial Research Institute for Automation and Measurements, PIAP Warsaw (2004) (in Polish)

    Google Scholar 

  7. Warsza, Z.L.: Backgrounds of two variable (2D) measurements of resistance increments by bridge cascade circuit. Proc. of SPIE (6347 part 2), R63472 (2006)

    Google Scholar 

  8. Stefanescu, D.M.: Handbook of Force Transducers: Principles and Components, p. 612. Springer (2011)

    Google Scholar 

  9. Warsza, Z.L.: Two-parameter measurements and signal conditioning in double – current supply four- terminal resistance circuits. Metrology and Measurement Systems XIII(1), 49–65 (2006)

    Google Scholar 

  10. Idźkowski, A., Makal, J., Warsza, Z.L.: Simultaneous measurement of two parameters by double current supplied bridge. Journal of Automation, Mobile Robotics and Intelligent Systems (JAMRIS) 6(2), 26–31 (2012)

    Google Scholar 

  11. LT3092 – programmable current source datasheet, Linear Technology

    Google Scholar 

  12. Shielding and Guarding, Analog Devices application note AN-347

    Google Scholar 

  13. O’Grady, A.: Transducer/Sensor Excitation and Measurement Techniques. Analog Dialogue 34(5), 1–6 (2000)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Adam Idźkowski .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2015 Springer International Publishing Switzerland

About this paper

Cite this paper

Idźkowski, A., Świętochowski, P., Warsza, Z.L., Walendziuk, W. (2015). Unconventional Double R/U Converter for Measurement of Two Quantities by a Single Differential Sensor. In: Szewczyk, R., Zieliński, C., Kaliczyńska, M. (eds) Progress in Automation, Robotics and Measuring Techniques. Advances in Intelligent Systems and Computing, vol 352. Springer, Cham. https://doi.org/10.1007/978-3-319-15835-8_10

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-15835-8_10

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-15834-1

  • Online ISBN: 978-3-319-15835-8

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics