Skip to main content

Verification of the Respiratory Parameters Derived from Impedance Pneumography during Normal and Deep Breathing in Three Body Postures

  • Conference paper
6th European Conference of the International Federation for Medical and Biological Engineering

Part of the book series: IFMBE Proceedings ((IFMBE,volume 45))

Abstract

We designed a small, battery-powered impedance pneumograph intended for holter monitoring of respiratory activity. Volume-related signal from impedance pneumo-graphy (IP) and airflow signal from reference method, pneumotachometry (PNT), were registered. First derivate of IP with PNT and IP with integral of PNT signals were compared in order to calculate slope values of linear regression. The effect of respiratory rate, depths of breathing, body posture, sex and body mass index (BMI) on slope values and coefficients of determination (R2) was determined. The measurements were conducted on a group of young volunteers without any respiratory diseases. An electrode configuration known for its good linearity between impedance and volume signals was chosen. Average R2 between IP signal and integral of PNT signal was 98.05%, and between first derivative of IP signal and PNT signal – 95.75%. It was demonstrated that the slope values were individually different and affected mostly by body posture.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2015 Springer International Publishing Switzerland

About this paper

Cite this paper

Młyńczak, M., Niewiadomski, W., Żyliński, M., Cybulski, G. (2015). Verification of the Respiratory Parameters Derived from Impedance Pneumography during Normal and Deep Breathing in Three Body Postures. In: Lacković, I., Vasic, D. (eds) 6th European Conference of the International Federation for Medical and Biological Engineering. IFMBE Proceedings, vol 45. Springer, Cham. https://doi.org/10.1007/978-3-319-11128-5_219

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-11128-5_219

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-11127-8

  • Online ISBN: 978-3-319-11128-5

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics