Abstract
This paper uses a power quality disturbance detection method based on improved phase-locked loop (IPLL) system. The IPLL is a closed-loop phase feedback control system, which can track the instantaneous phase and instantaneous amplitude of the input fundamental in real-time. The generated output signal can be used for the detection of a variety of power quality disturbances. Moreover, the internal parameters of the detection system and the change of power system’s frequency are robust. The use of the MATLAB/Simulink can study power quality problems, such as harmonics, frequency deviation, voltage swells, voltage interruptions, transient pulse, transient oscillation and voltage gap. Simulation results showed that the detection method had better accuracy and instantaneity.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Mao Niankui, Zhang Xuefeng (2010) Power quality signal disturbance detection and location. J Huainan Vocat Techn Coll 10(1):22–27
Zhao Jing, Qian Qingquan, He Zhengyou (2011) A way to identify of hybrid power quality disturbances. Autom Electr Power Syst 35(3):71–76
Wang Lixia, He Zhengyou, Dai Ming, Zhao Jing, Qian Qingquan (2009) A new power quality disturbance signal hierarchical identification method. Autom Electr Power Syst 33(24):65–69
Ge Naicheng, Cheng Haozhong, Lv Ganyun (2004) The power quality detection based on Matlab/Simulink simulation. For Electr 21(6):29–32
Lv Ganyun, Ding Qifeng, Ge Naicheng (2004) Detection method of power quality disturbance based on an improved PLL system. Proc CSU-EPSA 16(5):20–25
Lv Ganyun, Cheng Haozhong, Wang Xiaodong, Zhang Haoran (2006) Phase-shift of power quality detection method. Relay 43(3):60–62
Zhan Yong, Cheng Haozhong, Ding Yifeng, Lv Ganyun, Sun Yibin (2005) S-transform-based classification of power quality disturbance signals by support vector machines. Proc CSEE 25(4):51–56
Fang Guozhi, Hu Bingfang, Song Guoyi (2008) Three classes of grid disturbance signal detection method. Electr Power Autom Equip 28(6):74–76
Gong Jing (2009) The use of wavelet modulus maximum principle in the detection of disturbance signal for transient power quality. Northeast Electr Power Technol 20(5):10–13
Quan Huimin, Dai Yuxing (2007) Detection and localization of power quality disturbances based on S-transform module matrixes. Trans China Electrotechn soc 22(8):119–126
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer International Publishing Switzerland
About this paper
Cite this paper
Zhang, Z., Zhang, X. (2014). Research on the Detection Method of Power Quality Based on Phase-Locked Loop. In: Wang, W. (eds) Mechatronics and Automatic Control Systems. Lecture Notes in Electrical Engineering, vol 237. Springer, Cham. https://doi.org/10.1007/978-3-319-01273-5_33
Download citation
DOI: https://doi.org/10.1007/978-3-319-01273-5_33
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-01272-8
Online ISBN: 978-3-319-01273-5
eBook Packages: EngineeringEngineering (R0)