Abstract
A capacitive sensor for detecting the human heartbeat rate without direct contact with the skin is here described. The precordial movement changes the capacitance between the patch electrodes so modulating the frequency of an oscillator where the capacitance is inserted; as a consequence, the heartbeat signal can be obtained by demodulating the oscillating signal.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
J.G. Webster. Design of cardiac pacemaker, IEEE Press (1995), ISBN: 978-0780311343.
JognG. Webster. Medical Instrumentation, Application And Design, JohnWiley& Sons inc., 2009.
Lin, James C., et al.: ‘Microwave apex cardiography’, IEEE Trans. Microw. Theory Tech., 1979, MTT-27.
Ishijima., M.: ‘Monitoring of electrocardiograms in bed without utilizing body surface electrodes’, IEEE Trans. Biomed. Eng., 1993, 40, (6), pp. 593-594
Ueno, A., Akabane, Y., Kato, T., Hoshino, H., Kataoka, S., and Ishiyama., Y.: ‘Capacitive sensing of electrocardiographic potential through cloth from the dorsal surface of the body in a supine position: a preliminary study’, IEEE Trans. Biomed. Eng., 2007, 54, (4), pp. 759-766
V. Stornelli. Low Voltage Low Power Fully Differential Buffer, Journal of Circuits, Systems, and Computers (JCSC),vol.18, no.3, pp. 497-502, 2009
G. Ferri, V. Stornelli and M. Fragnoli. An integrated improved CCII topology for resistive sensor application, AnalogIntegr. Circuits Signal Process., vol. 48, 247-250, 2006.
V. Stornelli, L. Pantoli, G. Leuzzi, G. Ferri. Fully differential DDA-based fifth and seventh order Bessel low pass filters and buffers for DCR radio systems, Analog Integrated Circuits and Signal Processing, May 2013, vol. 75, Issue 2, pp 305-310.
V. Stornelli, G. Ferri. A 0.18μm CMOS DDCCII for portable lv-lp filters, Radioengineering, Vol. 22, n°2, June 213.
P. Colucci, G. Leuzzi, L. Pantoli,“Third order integrable UHF bandpass filter using active inductors”, Microwave And Optical Technology Letters, Vol. 54, n° 6 pp. 1426-1429, June 2012.
Y.T. Li. Pulse Oximetry, Stanford Undergraduate Research Journal 2, 10 (2007), 11-15.
G. Ferri, V. Stornelli, A. di Simone. A ccii-based high impedance input stage for biomedical applications, Journal of Circuits, Systems and Computers Vol. 20, 08, pp 1441-1447, 2011.
J.H. Oum, S.E. Lee, D.W. Kim, S. Hong. Non-contact heartbeat and respiration detector using capacitive sensor with Colpitts oscillator, Electronics Letters, 44 (2008), 87-88.
Gabriel, S., Lau, R.W., and Gabriel, C.: ‘The dielectric properties of biological tissues: 3 models for the frequency dependence’, Phys. Med. Biol., 1995, 41, (11), pp. 2271-2293.
G. Bucci, E. Fiorucci, C. Landi, G. Ocera. The Use of Wireless Network for Distributed Measurement Applications, Proc. IEEE Instrumentation and Measurement Technology Conference, Anchorage, USA, May 21-23, 2002.
G. Bucci, E. Fiorucci, C. Landi, G. Ocera. Architecture of a digital wireless data communication network for distributed sensor applications, Measurement, Journal of International Measurement Confederation, vol. 35, issue 1, (2004), pages 33-45.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer International Publishing Switzerland
About this paper
Cite this paper
Stornelli, V., Mantenuto, P., Ferri, G., Di Marco, P. (2014). A Compact Architecture for Heartbeat Monitoring. In: Di Natale, C., Ferrari, V., Ponzoni, A., Sberveglieri, G., Ferrari, M. (eds) Sensors and Microsystems. Lecture Notes in Electrical Engineering, vol 268. Springer, Cham. https://doi.org/10.1007/978-3-319-00684-0_57
Download citation
DOI: https://doi.org/10.1007/978-3-319-00684-0_57
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-00683-3
Online ISBN: 978-3-319-00684-0
eBook Packages: EngineeringEngineering (R0)