Abstract
The effectiveness of Fibre-Reinforced Polymer (FRP) and Textile-Reinforced Mortar (TRM) jackets was investigated experimentally and analytically in this study as a means of confining old-type reinforced concrete (RC) columns with limited capacity due to bond failure at lap splice regions. The local bond strength between lap spliced bars and concrete was measured experimentally along the lap splice region of six full-scale RC columns subjected to cyclic uniaxial flexure under constant axial load. The bond strength of two column specimens tested without retrofitting was found to be in good agreement with the predictions given by two existing bond models. These models were modified to account for the contribution of composite material jacketing to the bond resistance between lap spliced bars and concrete. The effectiveness of FRP and TRM jackets against splitting at lap splices was quantified as a function of jacket properties and geometry as well as in terms of the jacket effective strain, which was found to depend on the ratio of lap splice length to bar diameter. Consequently, simple equations for calculating the bond strength of lap splices in members confined with composite materials (FRP or TRM) are proposed.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
ACI Committee 408 (2003) Bond and development of straight reinforcing bars in tension (ACI 408R-03). American Concrete Institute, Farmington Hills, MI, 49 pp
Azizinamini A, Pavel R, Hatfield E, Ghosh SK (1999) Behaviour of lap-spliced reinforcing bars embedded in high-strength concrete. ACI Struct J 96(5):826–835
Bournas DA, Lontou PV, Papanicolaou CG, Triantafillou TC (2007) Textile-Reinforced Mortar (TRM) versus FRP confinement in reinforced concrete columns. ACI Struct J 104(6):740–748
Bournas DA, Triantafillou TC, Zygouris K, Stavropoulos F (2009) Textile-Reinforced Mortar (TRM) versus FRP jacketing in seismic retrofitting of RC columns with continuous or lap-spliced deformed bars. ASCE J Compos Constr 13(5):360–371
Cairns J, Arthur PD (1979) Strength of lapped splices in reinforced concrete columns. ACI Struct J 76(2):277–296
ElGawady M, Endeshaw M, McLean D, Sack R (2010) Retrofitting of rectangular columns with deficient lap splices. ASCE J Compos Constr 14(1):22–35
EN 1015–11 (1993) Methods of test for mortar for masonry – Part 11: Determination of flexural and compressive strength of hardened mortar. European Committee for Standardization. Brussels
fib (2000) Bond of reinforcement in concrete, Bulletin 10. International Federation for Structural Concrete, Lausanne
fib (2012) Model Code 2010 final draft, Bulletin 65. International Federation for Structural Concrete, Lausanne
Hamad BS, Rteil AA (2006) Comparison of roles of FRP sheets, stirrups, and steel fibres in confining bond critical regions. ASCE J Compos Constr 10(4):330–336
Harajli MH (2005) Behaviour of gravity load-designed rectangular concrete columns confined with fibre reinforced polymer sheets. ASCE J Compos Constr 9(1):4–14
Harajli MH, Dagher F (2008) Seismic strengthening of bond-critical regions in rectangular reinforced concrete columns using fibre-reinforced polymer wraps. ACI Struct J 105(1):68–77
Haroun MA, Feng MQ, Bhatia H, Baird K, Elsanadedy HM (1999) Structural qualification testing of composite-jacketed circular and rectangular bridge columns. Final report, California Department of Transportation/Department of Civil and Environmental Engineering, University of California at Irvine, Irvine, CA
Lettow S, Eligehausen R (2006) Formulation of application rules for lap splices in the new Model Code. Presentation, Task group 4.5 – Bond models, fib (federation internationale du Beton), Stuttgart, 13 Nov 2006
Lukose N, Gergely P, White RN (1982) Behaviour of reinforced concrete lapped splices for inelastic cyclic loading. ACI Struct J 79(5):355–365
Ma R, Xiao Y (1999) Seismic retrofit and repair of circular bridge columns with advanced composite materials. Earthq Spectra 15(4):747–764
Melek M, Wallace JW (2004) Cyclic behaviour of columns with short lap splices. ACI Struct J 101(6):802–811
Orangun CO, Jirsa JO, Breen JE (1977) Reevaluation of test data on development length and splices. ACI J 74(3):114–122
Panahshahi N, White RN, Gergely P (1992) Reinforced concrete compression lap splices under inelastic cyclic loading. ACI Struct J 89(2):164–175
Paulay T (1982) Lapped splices in earthquake-resisting columns. ACI Struct J 79(6):458–469
Saadatmanesh H, Ehsani MR, Jin L (1997) Seismic retrofitting of rectangular bridge columns with composite straps. Earthq Spectra 13(2):281–304
Seible F, Priestley MJN, Hegemier GA, Innamorato D (1997) Seismic retrofit of RC columns with continuous carbon fibre jackets. ASCE J Compos Constr 1(2):52–62
Triantafillou TC, Papanicolaou CG, Zissimopoulos P, Laourdekis T (2006) Concrete confinement with Textile-Reinforced Mortar jackets. ACI Struct J 103(1):28–37
Valluvan R, Kreger ME, Jirsa JO (1993) Strengthening of column splices for seismic retrofit of nonductile reinforced concrete frames. ACI Struct J 91(46):432–440
Zuo J, Darwin D (2000) Splice strength of conventional and high relative rib area bars in normal and high-strength concrete. ACI Struct J 97(4):630–641
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer International Publishing Switzerland
About this chapter
Cite this chapter
Bournas, D., Triantafillou, T. (2014). Bond Strength of Lap Splices in FRP and TRM Confined Concrete: Behavior and Design. In: Ilki, A., Fardis, M. (eds) Seismic Evaluation and Rehabilitation of Structures. Geotechnical, Geological and Earthquake Engineering, vol 26. Springer, Cham. https://doi.org/10.1007/978-3-319-00458-7_12
Download citation
DOI: https://doi.org/10.1007/978-3-319-00458-7_12
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-00457-0
Online ISBN: 978-3-319-00458-7
eBook Packages: Earth and Environmental ScienceEarth and Environmental Science (R0)