Abstract
The conservation of the built heritage represents nowadays a great challenge for the scientific community and for the heritage managers since historical buildings can typically face both seismic and climate related hazards. To increase the resilience and reduce the vulnerability of historical constructions, specific strategies and methodologies should be developed and applied. In the framework of the Shelter project, funded by the European Union’s Horizon 2020 program, the Church of Santa Croce in Ravenna (Italy) was taken as a case study for the validation of such methodologies, involving a multidisciplinary approach. In this work, the structural behavior of the Church of Santa Croce was investigated through the development of a finite element model and the implementation of a Structural Health Monitoring system, with the possibility of accessing data in real-time. First, the historical analysis of the construction and slightly-destructive tests were carried out to investigate the constructive details, the state of damage, and the mechanical properties of the materials. After acquiring a detailed knowledge level of the construction, modal analyses and nonlinear static numerical simulations were carried out to assess the modal parameters and to reproduce the existing crack pattern. On the one hand, the numerical analyses supported the design of the monitoring system itself; on the other hand, a model updating was carried out to calibrate mechanical parameters not explicitly obtained through testing. The adopted methodologies and approaches are described in the paper, together with the results of the numerical simulations and preliminary results acquired from the monitoring system.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Chiabrando, F., Colucci, E., Lingua, A., Matrone, F., Noardo, F., Spanò, A.: A European Interoperable Database (EID) to increase resilience of cultural heritage. Int. Arch. Photogramm. Remote Sens. Spat. Inf. Sci. 42, 151–158 (2018)
Sharifi, A.: A critical review of selected tools for assessing community resilience. Ecol. Ind. 69, 629–647 (2016)
Ahern, J.: From fail-safe to safe-to-fail: sustainability and resilience in the new urban world. Landsc. Urban Plan. 100(4), 341–343 (2011)
Ministero delle Infrastrutture e dei Trasporti: Aggiornamento delle ‘Norme Tecniche per le Costruzioni’. Gazzetta Ufficiale della Repubblica Italiana, Rome (2018)
EN 1998-3: Eurocode 8: design of structures for earthquake resistance-part 3: assessment and retrofitting of buildings. CEN (European Committee for Standardization), Brussels (2005)
DPCM 9/2/2011: Linee guida per la valutazione e la riduzione del rischio sismico del patrimonio culturale con riferimento alle Norme tecniche delle costruzioni di cui al decreto del Ministero delle Infrastrutture e dei trasporti del 14 gennaio, Rome (2008)
Ricceri, G.: Studi e ricerche nell’area di San Vitale, Galla Placidia e Santa Croce in Ravenna. SGEditoriali, Padova (1992)
Gelichi, S., Piolanti, P.N.: La chiesa di S. Croce a Ravenna: la sequenza architettonica. In: XLII corso di cultura sull’arte ravennate e bizantina. Ravenna, Edizioni del girasole (1995)
Massimiliano, D.: La basilica di Santa Croce - Nuovi contributi per Ravenna tardoantica, Edizioni del Girasole (2013)
Binda, L., Saisi, A., Tiraboschi, C.: Investigation procedures for the diagnosis of historic masonries. Constr. Build. Mater. 14(4), 199–233 (2000)
Binda, L., Saisi, A., Tiraboschi, C.: Application of sonic tests to the diagnosis of damaged and repaired structures. NDT E Int. 34(2), 123–138 (2001)
EN 772-1: Methods of test for masonry units-Part 1: Determination of compressive strength. Brussels. Comité Européen de Normalisation, Brussels (2011)
Henzel, J., Karl, S.: Determination of strength of mortar in the joints of masonry by compression tests on small specimens. Darmstadt Concrete 2(1), 123–136 (1987)
Allemang, R.J., Brown, D.L.: A unified matrix polynomial approach to modal identification. J. Sound Vib. 211(3), 301–322 (1998)
Ewins, D.J.: Modal Testing: Theory and Practice. Wiley, New York (2000)
Ministero delle Infrastrutture e dei Trasporti: Circolare n. 7 del 21 Gennaio 2019. Istruzioni per l’applicazione dell’«Aggiornamento delle “Norme tecniche per le costruzioni”» di cui al DM 17 gennaio 2018. CS LL. PP (2019)
Acknowledgments
This research was carried out in the framework of the SHELTER project, funded by the European Union’s Horizon 2020 research program, grant N. 821282. The contribution of Massimo Gardini (CSM Sistemi) to the design of the monitoring system is gratefully acknowledged.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2024 The Author(s), under exclusive license to Springer Nature Switzerland AG
About this paper
Cite this paper
Ferretti, F., Monteferrante, C., Mazzotti, C. (2024). Numerical Modelling and Structural Health Monitoring for Built Heritage Management: The Case of the Church of Santa Croce in Ravenna. In: Endo, Y., Hanazato, T. (eds) Structural Analysis of Historical Constructions. SAHC 2023. RILEM Bookseries, vol 46. Springer, Cham. https://doi.org/10.1007/978-3-031-39450-8_48
Download citation
DOI: https://doi.org/10.1007/978-3-031-39450-8_48
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-031-39449-2
Online ISBN: 978-3-031-39450-8
eBook Packages: EngineeringEngineering (R0)