Fault Protection Method of Single-Phase Break for Distribution Network Based on Current Ratio Between Negative and Zero Sequence Current

  • Conference paper
  • First Online:
Smart Grid and Innovative Frontiers in Telecommunications (SmartGIFT 2022)

Abstract

To solve the identification problem of single-phase break fault with power-side grounding (SPBF-PG) and single-phase break fault with load-side grounding (SPBF-LG), a protection method of single-phase break for distribution network is proposed, which is based on current ratio between negative and zero sequence current. The variation characteristics of sequence current of SPBF-PG and SPBF-LG are analyzed by using compound sequence network. Then the protection criterion of negative-zero sequence current amplitude ratio is constructed. This paper presents a new protection method for single-phase break fault (SPBF) which is not affected by line break location, load variation and transition resistance. The method is verified to be correct by simulation.

This work was supported by the National Natural Science Foundation of China (52207075).

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Tang, T., Huang, C., Li, Z., Yuan, X.:Identifying faulty feeder for single-phase high impedance fault in resonant grounding distribution system. Energies 12, 598 (2019)

    Google Scholar 

  2. Wang, S., Zhang, H., Xu, B.: Diagnosis of the type of single-phase disconnection and ground fault in the small current grounding system. Electr. Power Autom. Equipment 38(7), 134–139+147 (2018)

    Google Scholar 

  3. Wang, M., Lv, Y., Zou, H.: Analysis of lightning-caused break mechanism of 10 kV insulation-covered conductors and its countermeasures. High Voltage Eng. 33(1), 102–105 (2007)

    Google Scholar 

  4. Shen, H., Chen, W., Wang, S.: Simulation tests on lightning stroke-caused wire-breakage of 10 kV overhead transmission line. Power Syst. Technol. 35(01), 117–121 (2011)

    Google Scholar 

  5. Xue, Y., Chen, M., Cao, L.: Analysis of voltage characteristics of single-phase disconnection fault in ungrounded distribution system. Proc. CSEE 41(4), 1322–1333 (2021)

    Google Scholar 

  6. Zhang, L., Cao, L., Li, L.: Analysis and fault section location of single-phase open fault for ungrounding system. Power Syst. Prot. Control 46(16), 1–7 (2018)

    Google Scholar 

  7. Zhang, H., Cao, L., Feng, G.: Analysis of single-phase open fault for resonant grounded system. Proc. CSU-EPSA 31(2), 58–65 (2019)

    Google Scholar 

  8. Suwo, W., Zhang, Y., Yun, S.: Open-line fault diagnosis based on data association of MV distribution network. Electr. Power Autom. Equipment 37(7), 101–109 (2017)

    Google Scholar 

  9. Guo, N., Yun, S., Tian, Y.: Disconnected unground fault detection in medium voltage distribution network based on FC-AdaBoost. Electr. Meas. Instrum. 56(16), 1–6 (2019)

    Google Scholar 

  10. Chang, Z., Song, G., Zhang, W.: Characteristic analysis and fault segment location on negative sequence voltage and current of single-phase line breakage fault in distribution network. Power Syst. Technol. 44(8), 3065–3072 (2020)

    Google Scholar 

  11. Xiao, Y., Ouyang, J., Xiong, X.: Protection method of compound break fault with grounding for distribution network considering influence of fault resistance. Power Syst. Technol. 45(11), 4296–4307 (2021)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Xiaohan Li .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2023 ICST Institute for Computer Sciences, Social Informatics and Telecommunications Engineering

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Li, X., Tang, T., Zhou, Y., Yang, Z. (2023). Fault Protection Method of Single-Phase Break for Distribution Network Based on Current Ratio Between Negative and Zero Sequence Current. In: Yang, H., Fei, J., Qiang, T. (eds) Smart Grid and Innovative Frontiers in Telecommunications. SmartGIFT 2022. Lecture Notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering, vol 483. Springer, Cham. https://doi.org/10.1007/978-3-031-31733-0_7

Download citation

  • DOI: https://doi.org/10.1007/978-3-031-31733-0_7

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-031-31732-3

  • Online ISBN: 978-3-031-31733-0

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics