Abstract
Flow analysis carried out using phase contrast cardiac magnetic resonance imaging (PC-CMR) enables the quantification of important parameters that are used in the assessment of cardiovascular function. An essential part of this analysis is the identification of the correct CMR views and quality control (QC) to detect artefacts that could affect the flow quantification. We propose a novel deep learning based framework for the fully-automated analysis of flow from full CMR scans that first carries out these view selection and QC steps using two sequential convolutional neural networks, followed by automatic aorta and pulmonary artery segmentation to enable the quantification of key flow parameters. Accuracy values of 0.998 and 0.828 were obtained for view classification and QC, respectively. For segmentation, Dice scores were >0.964 and the Bland-Altman plots indicated excellent agreement between manual and automatic peak flow values. In addition, we tested our pipeline on an external validation data set, with results indicating good robustness of the pipeline. This work was carried out using multivendor clinical data consisting of 699 cases, indicating the potential for the use of this pipeline in a clinical setting.
B. Ruijsink and E. Puyol-Anton—Joint last authors.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Albà, X., Lekadir, K., Pereañez, M., Medrano-Gracia, P., Young, A.A., Frangi, A.F.: Automatic initialization and quality control of large-scale cardiac MRI segmentations. Med. Image Anal. 43, 129–141 (2018)
Bidhult, S., et al.: A new vessel segmentation algorithm for robust blood flow quantification from two-dimensional phase-contrast magnetic resonance images. Clin. Physiol. Funct. Imaging 39(5), 327–338 (2019)
Bratt, A., et al.: Machine learning derived segmentation of phase velocity encoded cardiovascular magnetic resonance for fully automated aortic flow quantification. J. Cardiovas. Mag. Reson. 21(1) (2019)
Hann, E., et al.: Quality control-driven image segmentation towards reliable automatic image analysis in large-scale cardiovascular magnetic resonance aortic cine imaging. In: Shen, D., et al. (eds.) MICCAI 2019. LNCS, vol. 11765, pp. 750–758. Springer, Cham (2019). https://doi.org/10.1007/978-3-030-32245-8_83
He, K., Zhang, X., Ren, S., Sun, J.: Deep residual learning for image recognition (2015). https://arxiv.org/abs/1512.03385
Huang, G., Liu, Z., Van Der Maaten, L., Weinberger, K.Q.: Densely connected convolutional networks. In: Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition, pp. 4700–4708 (2017)
Isensee, F., et al.: nnU-Net: a self-configuring method for deep learning-based biomedical image segmentation. Nat. Methods 18(2), 203–211 (2021)
Krizhevsky, A., Sutskever, I., Hinton, G.E.: ImageNet classification with deep convolutional neural networks. In: Advances in Neural Information Processing Systems, pp. 1097–1105 (2012)
Liu, Z., Mao, H., Wu, C.Y., Feichtenhofer, C., Darrell, T., Xie, S.: A convnet for the 2020s (2022). https://arxiv.org/abs/2201.03545
Nayak, K.S., et al.: Cardiovascular magnetic resonance phase contrast imaging. J. Cardiovasc. Magn. Reson. 17(1), 1–26 (2015)
Oksuz, I., et al.: Automatic CNN-based detection of cardiac MR motion artefacts using k-space data augmentation and curriculum learning. Med. Image Anal. 55, 136–147 (2019)
Petersen, S.E., et al.: Uk biobank’s cardiovascular magnetic resonance protocol. J. Cardiovasc. Magn. Reson. 18(1), 8 (2015)
Radosavovic, I., Kosaraju, R.P., Girshick, R., He, K., Dollár, P.: Designing network design spaces (2020). https://arxiv.org/abs/2003.13678
Rebergen, S.A., van der Wall, E.E., Doornbos, J., de Roos, A.: Magnetic resonance measurement of velocity and flow: Technique, validation, and cardiovascular applications. Am. Heart J. 126(6), 1439–1456 (1993)
Robinson, R., et al.: Automated quality control in image segmentation: Application to the UK Biobank cardiovascular magnetic resonance imaging study. J. Cardiovas. Mag. Res. 21(1) (2019)
Ruijsink, B., et al.: Fully automated, quality-controlled cardiac analysis from cmr: validation and large-scale application to characterize cardiac function. Cardiovas. Imaging 13(3), 684–695 (2020)
Sandler, M., Howard, A., Zhu, M., Zhmoginov, A., Chen, L.C.: Mobilenetv 2: Inverted residuals and linear bottlenecks (2018). https://arxiv.org/abs/1801.04381
Simonyan, K., Zisserman, A.: Very deep convolutional networks for large-scale image recognition. In: 3rd International Conference on Learning Representations, ICLR 2015 - Conference Track Proceedings, pp. 1–14 (2015)
Tarroni, G., et al.: Learning-based quality control for cardiac MR images. IEEE Trans. Med. Imaging 38(5), 1127–1138 (2019)
Vergani, V., Razavi, R., Puyol-Antón, E., Ruijsink, B.: Deep learning for classification and selection of cine cmr images to achieve fully automated quality-controlled cmr analysis from scanner to report. Front. Cardiovas. Med. 8(742640) (2021)
Wang, S., et al.: Deep generative model-based quality control for cardiac mri segmentation. In: Martel, A.L., et al. (eds.) MICCAI 2020. LNCS, vol. 12264, pp. 88–97. Springer, Cham (2020). https://doi.org/10.1007/978-3-030-59719-1_9
Watanabe, T., et al.: Accuracy of the flow velocity and three-directional velocity profile measured with three-dimensional cine phase-contrast mr imaging: verification on scanners from different manufacturers. Magn. Reson. Med. Sci. 18(4), 265–271 (2019)
Zhang, L., et al.: Automated quality assessment of cardiac mr images using convolutional neural networks. In: Tsaftaris, S.A., Gooya, A., Frangi, A.F., Prince, J.L. (eds.) SASHIMI 2016. LNCS, vol. 9968, pp. 138–145. Springer, Cham (2016). https://doi.org/10.1007/978-3-319-46630-9_14
Zhang, L., Gooya, A., Frangi, A.F.: Semi-supervised assessment of incomplete LV coverage in cardiac MRI using generative adversarial nets. In: Tsaftaris, S.A., Gooya, A., Frangi, A.F., Prince, J.L. (eds.) SASHIMI 2017. LNCS, vol. 10557, pp. 61–68. Springer, Cham (2017). https://doi.org/10.1007/978-3-319-68127-6_7
Acknowledgements
This work was supported by the UKRI London Medical Imaging & Artificial Intelligence Centre for Value Based Healthcare, and the Wellcome EPSRC Centre for Medical Engineering at the School of Biomedical Engineering and Imaging Sciences, King’s College London (WT 203148/Z/16/Z). The authors also acknowledge financial support from the National Institute for Health Research (NIHR) Cardiovascular MedTech Co-operative award to the Guy’s and St Thomas’ NHS Foundation Trust and the Department of Health National Institute for Health Research (NIHR) comprehensive Biomedical Research Centre award to Guy’s & St Thomas’ NHS Foundation Trust in partnership with King’s College London.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2022 The Author(s), under exclusive license to Springer Nature Switzerland AG
About this paper
Cite this paper
Chan, E. et al. (2022). Automated Quality Controlled Analysis of 2D Phase Contrast Cardiovascular Magnetic Resonance Imaging. In: Camara, O., et al. Statistical Atlases and Computational Models of the Heart. Regular and CMRxMotion Challenge Papers. STACOM 2022. Lecture Notes in Computer Science, vol 13593. Springer, Cham. https://doi.org/10.1007/978-3-031-23443-9_10
Download citation
DOI: https://doi.org/10.1007/978-3-031-23443-9_10
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-031-23442-2
Online ISBN: 978-3-031-23443-9
eBook Packages: Computer ScienceComputer Science (R0)