Skip to main content

Robotics in Functional Neurosurgery

  • Chapter
  • First Online:
Robotics in Neurosurgery

Abstract

Functional neurosurgery requires high levels of accuracy for stereotactic placement of leads to an intracranial target. The adoption of robotic-assisted neurosurgery in functional neurosurgery has reduced error and improved overall accuracy of lead placement. As centers develop experience with robotics, new workflows are developed to ensure efficiency in the operating room. This chapter discusses the relevant history and studies regarding the development of this technique and seeks to explain nuances of robotic registration, surgical workflow, and address some pitfalls for neurosurgeons looking to adopt robotics in their own functional practices.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 119.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Vazhayil V, et al. An overview of robotics in functional neurosurgery. Indian J Neurosurg. 2019;08:006–10.

    Article  Google Scholar 

  2. Kwoh YS, Hou J, Jonckheere EA, Hayati S. A robot with improved absolute positioning accuracy for CT guided stereotactic brain surgery. IEEE T Bio-med Eng. 1988;35:153–60.

    Article  CAS  Google Scholar 

  3. Faria C, et al. Review of robotic technology for stereotactic neurosurgery. IEEE Rev Biomed Eng. 2015;8:125–37.

    Article  Google Scholar 

  4. Faraji AH, Kokkinos V, Sweat JC, Crammond DJ, Richardson RM. Robotic-assisted stereotaxy for deep brain stimulation lead implantation in awake patients. Oper Neurosurg. 2020;19:444–52.

    Article  Google Scholar 

  5. Fenoy AJ, Simpson RK. Risks of common complications in deep brain stimulation surgery: management and avoidance: clinical article. J Neurosurg. 2014;120:132–9.

    Article  Google Scholar 

  6. Jitkritsadakul O, et al. Systematic review of hardware-related complications of deep brain stimulation: do new indications pose an increased risk? Brain Stimul. 2017;10:967–76.

    Article  Google Scholar 

  7. Neudorfer C, Hunsche S, Hellmich M, Majdoub FE, Maarouf M. Comparative study of robot-assisted versus conventional frame-based deep brain stimulation stereotactic neurosurgery. Stereot Funct Neuros. 2018;96:327–34.

    Article  Google Scholar 

  8. Paff M, et al. Two-year clinical outcomes associated with robotic-assisted subthalamic lead implantation in patients with Parkinson’s disease. J Robotic Surg. 2020;14:559–65.

    Article  Google Scholar 

  9. Liu L, et al. Frameless ROSA® robot-assisted lead implantation for deep brain stimulation: technique and accuracy. Oper Neurosurg. 2019;19:57–64.

    Article  CAS  Google Scholar 

  10. Jin H, et al. A comparative study of asleep and awake deep brain stimulation robot-assisted surgery for Parkinson’s disease. Npj Park Dis. 2020;6:27.

    Article  CAS  Google Scholar 

  11. Lefranc M, et al. Asleep robot-assisted surgery for the implantation of subthalamic electrodes provides the same clinical improvement and therapeutic window as awake surgery. World Neurosurg. 2017;106:602–8.

    Article  Google Scholar 

  12. 510(k) Premarket notification for Mazor renaissance system with brain application. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K120812. Accessed 5 July 2021.

  13. Ho AL, et al. Frameless robot-assisted deep brain stimulation surgery: an initial experience. Oper Neurosurg. 2019;17:424–31.

    Article  Google Scholar 

  14. Varma TRK, et al. Use of the NeuroMate stereotactic robot in a frameless mode for movement disorder surgery. Stereot Funct Neuros. 2004;80:132–5.

    Article  Google Scholar 

  15. Candela S, et al. Frameless robot-assisted pallidal deep brain stimulation surgery in pediatric patients with movement disorders: precision and short-term clinical results. J Neurosurg Pediatrics. 2018;22:416–25.

    Article  Google Scholar 

  16. von Langsdorff D, Paquis P, Fontaine D. In vivo measurement of the frame-based application accuracy of the Neuromate neurosurgical robot. J Neurosurg. 2015;122:191–4.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Amir H. Faraji .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2022 The Author(s), under exclusive license to Springer Nature Switzerland AG

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Austerman, R.J., Rajendran, S., Faraji, A.H. (2022). Robotics in Functional Neurosurgery. In: González Martínez, J.A., Cardinale, F. (eds) Robotics in Neurosurgery. Springer, Cham. https://doi.org/10.1007/978-3-031-08380-8_5

Download citation

  • DOI: https://doi.org/10.1007/978-3-031-08380-8_5

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-031-08379-2

  • Online ISBN: 978-3-031-08380-8

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics