Abstract
In this paper, work on monitoring of the condition state of external prestressingtendons on a concrete multi-span highway viaduct will be presented. During the principal inspection of the motorway viaduct, an unusual» S wave« deformation shape of external tendons in a hollow viaduct deck was observed, which could represent an early sign of degradation processes inside the prestressing tendons. A detailed visual inspection of all external tendons was therefore performed, where four different damage states based on the deformation of tendon line were heuristically defined. The results of this visual inspection showed that more than 10% of tendons were graded with moderate or strong damage state. It was assumed that the incipient corrosion of tendons is present which results into the degradation of grouting and to local fracture of steel wires. Consequently, the axial forces of all tendons were assessed using vibration method to support the reliability analysis of the viaduct in case of different tendon fracture scenarios. The measurements of natural frequencies of external tendons showed that the loss of prestressing force cannot be exclusively attributed to the observed damage states of tendons. Finally, a contactless visual monitoring of prestressing tendons with 30 digital cameras was established to monitor the progression of variation of deformation line. After 4 month of monitoring no additional damage on tendons was observed.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Ačanski V (2002) Viadukt 6–11, Technical report. Motorway Company in the Republic of Slovenia, DARS.d.d
Ačanski V (2005) Viadukt 6-11, Analiza statične in dinamične stabilnosti konstrukcije; desni objekt. Technical report. Motorway Company in the Republic of Slovenia, DARS .d.d
Bevc L, Švraka R (2020) Poročilo št. 534/19-620-3 o pregledu deformacij zunanjih kablov na viaduktu. Report. Motorway Company in the Republic of Slovenia, DARS .d.d
Ačanski V (2002) Viadukt 6-11. Dispozicija zunanjih kablov – desni objekt. Motorway Company in the Republic of Slovenia, DARS .d.d
Ačanski V (2002) Viadukt 6-11. Zvezek XVII. Grafične priloge. Motorway Company in the Republic of Slovenia, DARS .d.d
Ačanski V (2002) Viadukt 6-11. Zvezek XX. Grafične priloge. Motorway Company in the Republic of Slovenia, DARS .d.d
ETA-13/0979 (2018) DYWIDAG external and internal unbonded strand post-tensionig system. European Organisation for Technical Approvals, Brussels
DIN 8074: 1999–08. Polyethylene (PE) pipes. Dimensions
US Spec (2014) MP grout. High flow, high strength, non-shrink, non-corrosive grout
Marley Pipesystems (2009) HDPE physical properties
Liu H, Wans L, Tan G, Cheng Y (2013) Effective prestressing force testing method of external prestressed bridge based on frequency method. Appl Mech Mater 303–306:363–366
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2022 The Author(s), under exclusive license to Springer Nature Switzerland AG
About this paper
Cite this paper
Anžlin, A., Švraka, R., Hekič, D., Bohinc, U. (2022). Condition Monitoring of External Prestressing Tendons on a Concrete Multi-span Highway Viaduct. In: Pellegrino, C., Faleschini, F., Zanini, M.A., Matos, J.C., Casas, J.R., Strauss, A. (eds) Proceedings of the 1st Conference of the European Association on Quality Control of Bridges and Structures. EUROSTRUCT 2021. Lecture Notes in Civil Engineering, vol 200. Springer, Cham. https://doi.org/10.1007/978-3-030-91877-4_73
Download citation
DOI: https://doi.org/10.1007/978-3-030-91877-4_73
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-91876-7
Online ISBN: 978-3-030-91877-4
eBook Packages: EngineeringEngineering (R0)