Skip to main content

Retrofit of Damaged RC Columns Using CFRP Jackets

  • Conference paper
  • First Online:
10th International Conference on FRP Composites in Civil Engineering (CICE 2021)

Abstract

This paper presents results of an experimental program undertaken to investigate the possibility of application of carbon fiber reinforced polymer (CFRP) jackets to reduce the risk of rebar buckling of axially loaded RC columns with circular or rectangular cross-section. Ten RC columns with height of 300 mm and three different cross-sections, i.e. circular of 150 mm diameter, and square of 100 mm and 150 mm side, with two ratios of stirrup spacing to longitudinal bar diameter, i.e. 7.6 and 11.7, are tested. Scaling of 1/3 was followed in general, also in the rebar diameter and the concrete mix. The specimens, after being tested under axial compression up to failure, were strengthened with CFRP jackets using wet lay-up process. The number of CFRP layers used in the jacket was determined in relation to the degree of damage the columns had suffered according to a damage scale that is introduced. The results of this work are encouraging towards the potential of using CFRP jackets in RC columns with sparsely spaced stirrups, both for strengthening of intact RC columns and also as a retrofit technique for RC columns with buckled longitudinal bars, e.g. after the event of an earthquake. This application may be extremely helpful for the retrofit of RC columns in earthquake prone areas in buildings that were not designed according to the modern code principles and therefore their stirrups are sparsely spaced.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 509.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 649.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 649.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  • Bournas DA, Triantafillou TC (2011) Bar buckling in RC columns confined with composite materials. J Compos Constr 15:393–403

    Article  Google Scholar 

  • CEN (2005) European Standard EN1998-3:2005 Eurocode 8: Design of Structures for Earthquake Resistance - Part 3: Assessment and Retrofitting of Buildings. European Committee for Standardization, Brussels

    Google Scholar 

  • Esfahani MR, Kianoush MR (2005) Axial compressive strength of reinforced concrete columns wrapped with fibre reinforced polymers (FRP). Int J Eng (IJE) Trans B: Appl 18(1):1–11

    Google Scholar 

  • Galal K, Arafa A, Ghobarah A (2005) Retrofit of RC square short columns. Eng Struct 27(5):801–813

    Article  Google Scholar 

  • Code G (1954) Code for the Design and Construction of RC Structures. Ministry of Public Works, National Printing House, Athens, Greece (in Greek)

    Google Scholar 

  • Ilki A, Peker O, Karamuk E, Demir C, Kumbasar N (2008) FRP retrofit of low and medium strength circular and rectangular reinforced concrete columns. J Mater Civ Eng 20(2):169–188

    Article  Google Scholar 

  • Moretti ML, Miliokas E, Paparizos I (2021) Axial strength estimation of reinforced concrete columns confined through fiber reinforced polymer (FRP) jackets. J Multi Eng Sci Technol 8(4):13804–13818

    Google Scholar 

  • Moretti ML (2019) Effectiveness of different confining configurations of FRP jackets for concrete columns. Struct Eng Mech Int J 72(2):155–168

    Google Scholar 

  • Moretti ΜL, Arvanitopoulos E (2018) Overlap length for confinement of carbon and glass FRP-jacketed concrete columns. Compos Struct 195:14–25

    Article  Google Scholar 

  • Pellegrino C, Modena C (2010) Analytical model for FRP confinement of concrete columns with and without internal steel reinforcement. J Compos Constr 14:693–705

    Article  Google Scholar 

  • Rousakis TC, Karabinis AI (2012) Adequately FRP confined reinforced concrete columns under axial compressive monotonic or cyclic loading. Mater Struct 45:957–975

    Article  Google Scholar 

  • Sato DA, Ko H (2008) Modeling of reinforcement buckling in RC columns confined with FRP. J Adv Concr Technol 6(1):195–204

    Article  Google Scholar 

Download references

Acknowledgements

The authors wish to thank Mr. A. Koutselinis for manufacturing the specimens, Mr. T. Papatheocharis for technical advice at testing, as well as Sika Hellas SA for supplying the composite materials.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Marina L. Moretti .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2022 The Author(s), under exclusive license to Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Moretti, M.L., Miliokas, E., Paparizos, I. (2022). Retrofit of Damaged RC Columns Using CFRP Jackets. In: Ilki, A., Ispir, M., Inci, P. (eds) 10th International Conference on FRP Composites in Civil Engineering. CICE 2021. Lecture Notes in Civil Engineering, vol 198. Springer, Cham. https://doi.org/10.1007/978-3-030-88166-5_107

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-88166-5_107

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-88165-8

  • Online ISBN: 978-3-030-88166-5

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics