Abstract
Multi-hole orifice (MHO) flow meters are very often used for measuring the flow in the industrial processes. But nevertheless, the contamination influence to the flow parameters for MHO flow meters has not been numerically analyzed so far. In this paper, the influence of the contamination thickness to the flow parameters for MHO orifice meters with characteristic \(\beta\) parameter will be analysed. The pressure drop, singular pressure loss coefficient and discharge coefficient will be analysed for different values of contamination thickness and compared to the results without contamination. The grid sensitivity study will be performed for flow meter without contamination so the presented results will be grid independent.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Laws, E.M., Quazzane, A.K.: Compact, installation for differential flow meters. Flow Meas. Instrum. 5(2), 79–85 (1994)
Malavsi, S., Messa, G., Fratino, U., Pagano, A.: On the pressure losses through perforated plates. Flow Meas. Instrum. 28(1), 57–66 (2012)
Zhao, T., Zhang, J., Ma, L.: A general structural design methodology for multi-hole orifices and its experimental application. J. Mech. Sci. Tecnol. 25, 2237–2246 (2011)
Ozahi, E.: An analysis on the pressure loss through perforated plates at moderate Rejnolds number in turbulent flow regime. Flow Meas. Instrum. 43(1), 6–13 (2015)
Đurđević, M., Bukurov, M., Tašin, S., Bikić, S.: Experimental research of single-hole and multi-hole orifice gas flow meters. Flow Meas. Instrum. 70, 101650 (2019)
Huang, S., Ma, T., Wang, D., Lin, Z.: Study on discharge coefficient of perforated orifices as a new kind of flowmeter. Exp. Therm. Fluid Sci. 46, 74–83 (2013)
Shanfang, H., Taiyi, M., Dong, W., Zonghu, L.: Study on discharge coefficient of perforated orifices as a new kind of flowmeter. Exp. Therm. Fluid Sci. 46, 74–83 (2013)
Gronych, T., Jeřáb, M., Peksa, L., Wild, J., Stanêk, F., Vičar, M.: Experimental study of gas flow through a multi-opening orifice. Vacuum 86, 1759–1763 (2012)
Morrison, G.L., Terracina, D., Brewer, C., Hall, K.R.: Response of a slotted orifice flow meter to an air/water mixture. Flow Meas. Instrum. 12, 175–180 (2001)
Dong, Z.Y., Chen, Q.Q., Yang, Y.G., Shi, B.: Experimental and numerical study of hydrodynamic cavitation of orifice plates with multiple triangular holes. Appl. Mech. Mater. 256, 2519–2522 (2013)
Rudolf, P., Kubina, D., Hudec, M., Kozák, J., Maršálek, B., Maršálková, E., Pochylý, F.: Experimental investigation of hydrodynamic cavitation through orifices of different geometries, vol. 143, 02098 (2017)
Gao, Z., Qian, J. Jin, Z.: Experimental and numerical study of cavitation inside sharp-edged multi-hole orifice plate. In: Katz, J. (ed.) Proceedings of the 10th International Symposium on Cavitation (CAV2018). ASME Press (2018)
Gan, G., Riffat, S.B.: Pressure loss characteristics of orifice and perforated plates. Exp. Therm. Fluid Sci. 14(1), 219–226 (1997)
Liu, H., Chen, H., Tian, H., Jin, T.: Numerical study on performance of perforated plate applied to cryogenic fluid flowmeter. J. Zhejiang Univ. Sci. Appl. Phys. Eng. 17(3), 230–239 (2016)
Guo, B.Y., Hou, Q.F., Yu, A.B., Li, L.F., Guo, J.: Numerical modelling of the gas flow through perforated plates. Chem. Eng. Res. Des 91(3), 403–408 (2013)
El Drainy, Y.A., Saqr, K.M., Aly, H.S., Mohd, M.N.: CFD Analysis of incompressible turbulent swirling flow through Zanker Plate. Eng. Appl. Comput. Fluid Mech. 3(4), 562–572 (2009)
Kumar, P., Wong, M., Bing, M.: A CFD study of low pressure wet gas metering using slotted orfice meters. Flow Meas. Instrum. 22, 33–42 (2011)
Barki, M., Ganesha, T., Math, M.C.: CFD Analysis and comparison of fluid flow through a single hole and multi hole orifice plate. Int. J. Res. Advent. Technol. 2(89), 6–15 (2014)
Singh, V.K., Tharakan, T.J.: Numerical simulations for multi-hole orifice flow meter. Flow Meas. Instrum. 45, 375–383 (2015)
Mehmood, M.A., Ibrahim, M.A., Ullah, A., Inayat, M.H.: CFD study of pressure loss characteristics of multi-holed orifice plates using central composite design. Flow Meas. Instrum. 70, 101654 (2019)
Reader-Harris, M., Barton, N., Hodges, D.: The effect of contaminated orifice plates on the discharge coefficient. Flow Meas. Instrum. 25, 2–7 (2012)
Imamović, J., Hasečić, A., Bikić, S., Džaferović, E.: Numerical analysis of the contamination influence on the parameters of gas flow through single-hole orifice meter. In: 18th International Conference on Numerical Analysis and Applied Mathematics (ICNAAM), Greece (2020)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2021 The Author(s), under exclusive license to Springer Nature Switzerland AG
About this paper
Cite this paper
Hasečić, A., Bikić, S., Džaferović, E. (2021). Numerical Investigation of the Contamination Thickness Influence to the Flow Parameters for Multi-hole Orifice Flow Meter. In: Karabegović, I. (eds) New Technologies, Development and Application IV. NT 2021. Lecture Notes in Networks and Systems, vol 233. Springer, Cham. https://doi.org/10.1007/978-3-030-75275-0_92
Download citation
DOI: https://doi.org/10.1007/978-3-030-75275-0_92
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-75274-3
Online ISBN: 978-3-030-75275-0
eBook Packages: Intelligent Technologies and RoboticsIntelligent Technologies and Robotics (R0)