Skip to main content

Use of an Infrared Spectroscopic Method for Isotopic Analysis of Gaseous Uranium Hexafluoride

  • Conference paper
  • First Online:
Metal-Matrix Composites

Abstract

A high performance infrared (HPIR) system was developed and demonstrated for the infrared absorption analysis of uranium-235 and uranium-238 isotopes in uranium hexafluoride gas samples. The method takes advantage of the recent commercial availability of quantum cascade lasers (QCL) and has required the use of advanced statistical data analysis, as well as materials selection due to the chemical reactivity of uranium hexafluoride gas. Sweeping the QCL over the spectral range and sampling via a high-rate analog-to-digital converter provided 0.0005 cm−1 spectral resolution, allowing for high-precision measurements of the isotopic peak shift. A data analysis method was developed using principal component analysis to predict the isotope weight percent content of uranium-235. The HPIR precision, accuracy, and error were evaluated for a wide range of isotopic ratio samples (0.287–93.7 weight percent uranium-235), and the results were compared to the International Target Values (ITVs) set forth by the International Atomic Energy Agency (IAEA) for nondestructive and destructive analytical techniques used in safeguards verification under the Treaty on the Non-proliferation of Nuclear Weapons. The method meets or surpasses the IAEA ITVs for nondestructive analysis of samples with isotopic content of depleted to highly enriched. The results also demonstrated the capability of the HPIR system to correctly predict the uranium-235 weight percent content of a mislabeled sample whose isotopic distribution was validated by mass spectroscopic measurements. The HPIR measurement is nondestructive and, thus, allows for confirmatory analyses of the exact sample at a designated IAEA laboratory if higher resolution or a certified analysis is needed.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 189.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 249.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 249.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Richter S, Goldberg SA (2003) Improved techniques for high accuracy isotope ration measurements of nuclear materials using thermal ionization mass spectrometry. Int J Mass Spectrom 229(3):181–197

    Article  CAS  Google Scholar 

  2. Simpson A, McElhaney S (2010) Fast enrichment screening for safeguards applications. IAEA-CN-184/093

    Google Scholar 

  3. Dubois J, Shaw RA (2004) IR spectroscopy in clinical and diagnostic applications. Anal Chem 76(19):360A–367A

    Article  CAS  Google Scholar 

  4. Stanic V, Maia FCB, Freitas RO, Montoro FE, Evans-Lutterodt K (2018) The chemical fingerprint of hair melanosomes by infrared nano-spectroscopy. Nanoscale 10(29):14245–14253

    Article  CAS  Google Scholar 

  5. Bhargava R (2012) Infrared Spectroscopic Imaging: the next generation. Appl Spectrosc 66(10):1091–1120

    Article  CAS  Google Scholar 

  6. Amanti MI, Fischer M, Scalari G, Beck M, Faist J (2009) Low-divergence single-mode terahertz quantum cascade laser. Nat Photon 3:586–590

    Article  CAS  Google Scholar 

  7. Nasim H, Jamil Y (2013) Recent advancements in spectroscopy using tunable diode lasers. Laser Phys Lett 10(4):043001

    Google Scholar 

  8. Grigor’ev GY, Lebedeva AS, Malyugin SL, Nabiev SS, Nadezhdinskii AI, Ponurovskii YY (2008) Investigation of 235UF6 and 238UF6 spectra in the mid-IR range. At. Energy 104:398–403

    Google Scholar 

  9. Nabiev SS, Semenov VM, Stavrovskii DB, Men’shikov PL, Men’shikov LI, Grigor’ev GY (2017) Measurements of the isotopic composition of UF6 according to the fine structure of the IR absorption spectrum in the ν1 + ν3 band. Russ J Phys Chem B 11:61–76

    Google Scholar 

  10. Fessler KAS, O’Rourke PE, DeRoller NF, Simmons D, Serkiz SM (2020) Infrared spectroscopic method for uranium isotopic analysis. In: Proceeding of SPIE 11416, chemical, biological, radiological, nuclear, and explosives (CBRNE) sensing XXI, 114160R (18 May 2020). https://doi.org/10.1117/12.2559314

  11. Amphlett CB, Mullinger LW, Thomas LF (1948) Some physical properties of uranium hexafluoride. Trans Faraday Soc 44:927–938

    Article  CAS  Google Scholar 

  12. Ingle Jr. JD, Crouch SR (1988) Optical components of spectrometers. In: Spectrochemical analysis. Prentice Hall, New Jersey, 35.1

    Google Scholar 

  13. Esplin MP, Barowy WM, Huppi RJ, Rothman LS, Vanasse GA (1988) High resolution infrared spectroscopy of carbon dioxide and nitrous oxide at elevated temperatures. [AFGL-TR, 88-67.; Environmental Research Papers, no. 999] Hanscom AFB, Mass

    Google Scholar 

  14. Cox DM, Elliott J (1979) IR spectroscopy of UF6. Spectrosc Lett 12(4):275–280

    Article  CAS  Google Scholar 

  15. Nadezhdinskii A, Ponurovskii Y, Shapovalov Y, Stavrovskii D, Bolyasov D, Grigor’ev G, Gorshunov N, Malyugin S, Nabiev S (2005) Tunable diode laser spectroscopy application for detection and isotope ratio measurements of UF6 molecules. In: Proceeding of TDLS-2005 126

    Google Scholar 

  16. Blue SC, Underwood DE (1990) The corrosion of highly alloyed metals by fluorinating gases. KY/L-1990, Lockheed Martin Utility Services, INC., Paducah, Kent

    Google Scholar 

  17. McDowell RS, Asprey LB, Paine RT (1974) Vibrational spectrum and force field of uranium hexafluoride. J Chem Phys 61(9):3571–3580

    Google Scholar 

Download references

Acknowledgements

This document was prepared in conjunction with work accomplished under Contract No. DE-AC09-09SR22505 with the U.S. Department of Energy (DOE) National Nuclear Security Administration (NA).

Disclaimer

This work was prepared under an agreement with and funded by the U.S. Government. Neither the U. S. Government or its employees, nor any of its contractors, subcontractors or their employees, makes any express or implied: (1) warranty or assumes any legal liability for the accuracy, completeness, or for the use or results of such use of any information, product, or process disclosed; or (2) representation that such use or results of such use would not infringe privately owned rights; or (3) endorsement or recommendation of any specifically identified commercial product, process, or service. Any views and opinions of authors expressed in this work do not necessarily state or reflect those of the United States Government, or its contractors, or subcontractors.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to K. Alicia Strange Fessler .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2021 The Minerals, Metals & Materials Society

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Fessler, K.A.S., O’Rourke, P.E., DeRoller, N.F., Simmons, D., Serkiz, S.M. (2021). Use of an Infrared Spectroscopic Method for Isotopic Analysis of Gaseous Uranium Hexafluoride. In: Srivatsan, T.S., Harrigan, Jr., W.C., Hunyadi Murph, S. (eds) Metal-Matrix Composites. The Minerals, Metals & Materials Series. Springer, Cham. https://doi.org/10.1007/978-3-030-65249-4_12

Download citation

Publish with us

Policies and ethics