Abstract
Renal duplex sonography (RDS) has become the screening test of choice to detect hemodynamically significant renal artery stenosis and renal artery occlusion. In addition to the role of RDS in the detection of native disease, it has become a valuable method to confirm intraoperative technical success of open renal artery repair as well as a follow-up surveillance technique to evaluate both open operative repair and percutaneous intervention. This chapter will summarize these applications and the anticipated results of each.
Similar content being viewed by others
References
Hansen KJ, Tribble RW, Reavis SW, Canzanello VJ, Craven TE, Plonk GW Jr, Dean RH. Renal duplex sonography: evaluation of clinical utility. J Vasc Surg. 1990;12(3):227–36.
Pearce JD, Edwards MS, Craven TE, English WP, Mondi MM, Reavis SW, Hansen KJ. Renal duplex parameters, blood pressure, and renal function in elderly people. Am J Kidney Dis. 2005;45(5):842–50.
Mostbeck GH, Kain R, Mallek R, Derfler K, Walter R, Havelec L, Tscholakoff D. Duplex Doppler sonography in renal parenchymal disease. Histopathologic correlation. J Ultrasound Med. 1991;10(4):189–94.
Ikee R, Kobayashi S, Hemmi N, Imakiire T, Kikuchi Y, Moriya H, Suzuki S, Miura S. Correlation between the resistive index by Doppler ultrasound and kidney function and histology. Am J Kidney Dis. 2005;46(4):603–9.
Radermacher J, Ellis S, Haller H. Renal resistance index and progression of renal disease. Hypertension. 2002;39(2 pt 2):699–703.
Cohn EJ Jr, Benjamin ME, Sandager GP, Lilly MP, Killewich LA, Flinn WR. Can intrarenal duplex waveform analysis predict successful renal artery revascularization? J Vasc Surg. 1998;28(3):471–80. discussion 480-1.
Pearce JD, Craven TE, Edwards MS, Corriere MA, Crutchley TA, Fleming SH, Hansen KJ. Associations between renal duplex parameters and adverse cardiovascular events in the elderly: a prospective cohort study. Am J Kidney Dis. 2010;55(2):281–90.
Hansen KJ. Prevalence of ischemic nephropathy in the atherosclerotic population. Am J Kidney Dis. 1994;24(4):615–21.
Hansen KJ, Reavis SW, Dean RH. Duplex scanning in renovascular disease. Geriatr Nephrol Urol. 1996;6:89–97.
Hansen KJ, O’Neil EA, Reavis SW, Craven TE, Plonk GW Jr, Dean RH. Intraoperative duplex sonography during renal artery reconstruction. J Vasc Surg. 1991;14(3):364–74.
Dougherty MJ, Hallett JW Jr, Naessens JM, Bower TC, Cherry KJ, Gloviczki P, et al. Optimizing technical success of renal revascularization: the impact of intraoperative color-flow duplex ultrasonography. J Vasc Surg. 1993;17:849–57.
Cherr GS, Hansen KJ, Craven TE, Edwards MS, et al. Surgical management of atherosclerotic renovascular disease. J Vasc Surg. 2002;35:236–45.
Hudspeth DA, Hansen KJ, Reavis SW, Starr SM, Appel RG, Dean RH. Renal duplex sonography after treatment of renovascular disease. J Vasc Surg. 1993;18(3):381–8.
Mohabbat W, Greenberg RK, Mastracci TM, Cury M, Morales JP, Hernandez AV. Revised duplex criteria and outcomes for renal stents and stent grafts following endovascular repair of juxtarenal and thoracoabdominal aneurysms. J Vasc Surg. 2009;49:827–37.
Chi YW, White CJ, Thornton S, Milani RV. Ultrasound velocity criteria for renal in-stent restenosis. J Vasc Surg. 2009;50:119–23.
Duong MH, Mackenzie TA, Zwolak RM, Kaplan AV, Robb JF, Thompson CA. Correlation of invasive Doppler flow wire with renal duplex ultrasonography in the evaluation of renal artery stenosis: the renal artery stenosis invasive Doppler (RAIDER) study. J Vasc Surg. 2007;45:284–8.
Savader SJ, Lund GB, Venbrux AC. Doppler flow wire evaluation of renal artery blood flow before and after PTA: initial results. J Vasc Interv Radiol. 1998;9(3):451–60.
Fleming SH, Davis RP, Craven TE, Deonanan JK, Godshall CJ, Hansen KJ. Accuracy of duplex sonography scans after renal artery stenting. J Vasc Surg. 2010;52(4):953–7. discussion 958
Bakker J, Beutler JJ, Elgersma OEH, de Lange EE, de Kort GAP, Beek FJA. Duplex ultrasonography in assessing restenosis of renal artery stents. Cardiovasc Intervent Radiol. 1999;22:475–80.
del Conde I, Galin ID, Trost B, Kang J, Lookstein R, Woodward M, et al. Renal artery duplex ultrasound criteria for the detection of significant in-stent restenosis. Catheter Cardiovasc Interv. 2014;83:612–8.
Kohler TR, Zierler RE, Martin RL, Nicholls SC, Bergelin RO, Kazmers A, et al. Noninvasive diagnosis of renal artery stenosis by ultrasonic duplex scanning. J Vasc Surg. 1986;4:450–6.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Section Editor information
Rights and permissions
Copyright information
© 2021 Springer Nature Switzerland AG
About this entry
Cite this entry
Sheehan, M.K., Reavis, S., Edwards, M.S., Hansen, K.J. (2021). Duplex Evaluation After Renal Artery Intervention. In: AbuRahma, A.F., Perler, B.A. (eds) Noninvasive Vascular Diagnosis. Springer, Cham. https://doi.org/10.1007/978-3-030-49616-6_50-1
Download citation
DOI: https://doi.org/10.1007/978-3-030-49616-6_50-1
Received:
Accepted:
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-49616-6
Online ISBN: 978-3-030-49616-6
eBook Packages: Springer Reference MedicineReference Module Medicine