Abstract

Neonatal Intensive Care Units (NICU) are environments with a high level of sensory stress. Medical advances and technology have contributed to increase the ratio of survival of premature infants but some devices and practices expose these babies to excessive noise and toxic sensory stimuli for which they are not prepared. This is related to an increase of neonatal morbidities, that are considered as minor sequelae, but that can greatly alter the life of the child and the family. Those responsible for hospital management and caregivers who want to take a step forward, need standards to guarantee the benefit of neonatal health and a proper physical and cognitive development of these babies. Design activity, from a Human-Centered Design approach (HCD), together with Developmental Centered Care (DC) contribute to identify and reduce adverse environmental conditions for newborns and premature infants. The purpose of this paper is to establish a method to provide design recommendations and good practice guidelines from evidence and especially from in-situ observations carried out in neonatal units by a multidisciplinary team (i.e., nurses, NICU supervisors and designers). Thus, we identify proposals to reduce stress situations and obtain potential benefits in the development of the hospitalized infant through adaptation of the NICU macroenvironment (i.e. the reduction of light and noise).

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Cardoso, S.M.S., Kozlowski, L.D.C., Lacerda, A.B.M.D., Marques, J.M., Ribas, A.: Newborn physiological responses to noise in the neonatal unit. Braz. J. Otorhinolaryngol. 81(6), 583–588 (2015). https://doi.org/10.1016/j.bjorl.2014.11.008

    Article  Google Scholar 

  2. Als, H.: The newborn communicates. J. Commun. 27(2), 66–73 (1977). https://doi.org/10.1111/j.1460-2466.1977.tb01828.x

    Article  Google Scholar 

  3. Als, H., Lawhon, G., Duffy, F.H., McAnulty, G.B., Gibes-Grossman, R., Blickman, J.G.: Individualized developmental care for the very low-birth-weight preterm infant: medical and neurofunctional effects. JAMA 272(11), 853–858 (1994). https://doi.org/10.1001/jama.1994.03520110033025

    Article  Google Scholar 

  4. Giacomin, J.: What is human centred design? Des. J. 17(4), 606–623 (2014)

    MathSciNet  Google Scholar 

  5. Maguire, M.: Methods to support human-centred design. Int. J. Hum.-Comput. Stud. 55(4), 587–634 (2001)

    Article  Google Scholar 

  6. Wilkinson, C.R., De Angeli, A.: Applying user centred and participatory design approaches to commercial product development. Des. Stud. 35(6), 614–631 (2014)

    Article  Google Scholar 

  7. Rejón, J.V.: Showing the value of ethnography in business. In: Ethnographic Praxis in Industry Conference Proceedings, vol. 2009, no. 1, pp. 162–169. Wiley/Blackwell, August 2009. https://doi.org/10.1111/j.1559-8918.2009.tb00136.x

  8. Özcan, E., Birdja, D., Edworthy, J.R.: A holistic and collaborative approach to audible alarm design. Biomed. Instrum. Technol. 52(6), 422–432 (2018). https://doi.org/10.2345/0899-8205-52.6.422

    Article  Google Scholar 

  9. Romeu, J., Cotrina, L., Perapoch, J., Linés, M.: Assessment of environmental noise and its effect on neonates in a Neonatal Intensive Care Unit. Appl. Acoust. 111, 161–169 (2016). https://doi.org/10.1016/j.apacoust.2016.04.014

    Article  Google Scholar 

  10. Honan, L., Funk, M., Maynard, M., Fahs, D., Clark, J.T., David, Y.: Nurses’ perspectives on clinical alarms. Am. J. Crit. Care 24(5), 387–395 (2015). https://doi.org/10.4037/ajcc2015552

    Article  Google Scholar 

  11. Benzies, K.M., Shah, V., Aziz, K., Lodha, A., Misfeldt, R.: The health care system is making ‘too much noise’ to provide family-centered care in neonatal intensive care units: Perspectives of health care providers and hospital administrators. Intensive Crit. Care Nurs. 50, 44–53 (2019). https://doi.org/10.1016/j.iccn.2018.05.001

    Article  Google Scholar 

  12. Lasky, R., Williams, A.: Noise and light exposures for extremely low birth weight newborns during their stay in the neonatal intensive care unit. Pediatrics 123(2), 540–546 (2009)

    Article  Google Scholar 

  13. Sanz-Segura, R., Romero-Piqueras, C., Manchado-Pérez, E., Özcan, E.: Service design and sound: a chance for exploration in oncological treatment rooms. In: Advances on Mechanics, Design Engineering and Manufacturing II, pp. 639–648. Springer, Cham (2019). https://doi.org/10.1007/978-3-030-12346-8_62

  14. Sanz Segura, R., Manchado Pérez, E.: Product sound design as a valuable tool in the product development process. Ergon. Des. 26(4), 20–24 (2018). https://doi.org/10.1177/1064804618772997

    Article  Google Scholar 

  15. Carvalhais, C., da Silva, M.V., Xavier, A., Santos, J.: Good practices to reduce noise levels in the neonatal intensive care unit. In: Occupational and Environmental Safety and Health, pp. 297–302. Springer, Cham (2019). https://doi.org/10.1007/978-3-030-14730-3_32

  16. Weber, A., Harrison, T.M.: Reducing toxic stress in the neonatal intensive care unit to improve infant outcomes. Nurs. Outlook (2018). https://doi.org/10.1016/j.outlook.2018.11.002

  17. Carmel-Gilfilen, C., Portillo, M.: Designing with empathy: humanizing narratives for inspired healthcare experiences. HERD: Health Environ. Res. Des. J. 9(2), 130–146 (2016)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Rosana Sanz-Segura .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Sanz-Segura, R., Manchado-Perez, E., Ferrer-Duce, M.P., Gonzalez de la Cuesta, D., Özcan, E. (2020). Design Guidelines for Light and Noise Management in the Neonatal Intensive Care Unit. In: Cavas-Martínez, F., Sanz-Adan, F., Morer Camo, P., Lostado Lorza, R., Santamaría Peña, J. (eds) Advances in Design Engineering. INGEGRAF 2019. Lecture Notes in Mechanical Engineering. Springer, Cham. https://doi.org/10.1007/978-3-030-41200-5_31

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-41200-5_31

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-41199-2

  • Online ISBN: 978-3-030-41200-5

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics