Abstract

This chapter describes the acquisition parameters for bone SPECT/CT of the spine. The recommendations of the European Association of Nuclear Medicine (EANM) practice guidelines are summarized, and more detailed parameters are provided for the illustrations used in this section. The role and pitfalls of the recently introduced metal artifact reduction (MAR) algorithms are illustrated.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Institutional subscriptions

References

  • Cuvilliers C, Palard-Novello X, Pontoizeau C, Meneret P, Devillers A, Le Jeune F, et al. The added value of bloodpool SPECT/CT in painful non-operated foot and ankle undiagnosed with standard three-phase bone scintigraphy. Front Med (Lausanne). 2021;8:634419.

    Article  PubMed  Google Scholar 

  • Komber H, Little D, Cade S, Graham R, Redman S. Comparing the patient experience between a novel 360 degrees gamma camera (VERITON-CT) and a conventional dual head gamma camera. J Nucl Med Technol. 2021;50(2):132–6.

    Article  PubMed  Google Scholar 

  • Phillips WT, Gorzell BC, Martinez RA, Salman UA, Cooper AW, Stocker DJ, et al. Fewer-angle SPECT/CT blood pool imaging for infection and inflammation. J Nucl Med Technol. 2021;49(1):39–43.

    Article  PubMed  Google Scholar 

  • Rager O, Nkoulou R, Exquis N, Garibotto V, Tabouret-Viaud C, Zaidi H, et al. Whole-body SPECT/CT versus planar bone scan with targeted SPECT/CT for metastatic workup. Biomed Res Int. 2017;2017:7039406.

    Article  PubMed  PubMed Central  Google Scholar 

  • Van den Wyngaert T, Strobel K, Kampen WU, Kuwert T, van der Bruggen W, Mohan HK, et al. The EANM practice guidelines for bone scintigraphy. Eur J Nucl Med Mol Imaging. 2016;43(9):1723–38.

    Article  PubMed  PubMed Central  Google Scholar 

  • Verschueren J, Albert A, Carp L, Ceyssens S, Huyghe I, Stroobants S, et al. Bloodpool SPECT as part of bone SPECT/CT in painful total knee arthroplasty (TKA): validation and potential biomarker of prosthesis biomechanics. Eur J Nucl Med Mol Imaging. 2019;46(4):1009–18.

    Article  PubMed  Google Scholar 

  • Wayer DR, Kim NY, Otto BJ, Grayev AM, Kuner AD. Unintended consequences: review of new artifacts introduced by iterative reconstruction CT metal artifact reduction in spine imaging. AJNR Am J Neuroradiol. 2019;40(11):1973–5.

    CAS  PubMed  PubMed Central  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Tim Van den Wyngaert .

Editor information

Editors and Affiliations

Section Editor information

Rights and permissions

Reprints and permissions

Copyright information

© 2023 Springer Nature Switzerland AG

About this entry

Check for updates. Verify currency and authenticity via CrossMark

Cite this entry

Van den Wyngaert, T. (2023). Spine: Bone SPECT/CT Acquisition Protocol. In: Van den Wyngaert, T., Gnanasegaran, G., Strobel, K. (eds) Clinical Atlas of Bone SPECT/CT. Springer, Cham. https://doi.org/10.1007/978-3-030-32256-4_78-1

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-32256-4_78-1

  • Received:

  • Accepted:

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-32256-4

  • Online ISBN: 978-3-030-32256-4

  • eBook Packages: Springer Reference MedicineReference Module Medicine

Publish with us

Policies and ethics