Skip to main content

Real-Time Tomographic Image Reconstruction in PET Using the Pseudoinverse of the System Response Matrix

  • Conference paper
  • First Online:
Basic Concepts in Nuclear Physics: Theory, Experiments and Applications (RÁBIDA 2018)

Abstract

Positron Emission Tomography (PET), is one of the most recent medical imaging techniques, and it is commonly used in oncology, cardiology and neurology. PET is based on the detection in coincidence of the two 511 keV photons produced in the annihilation of a positron with an electron of the media. Positrons are emitted by radionuclides linked to a molecule of interest (tracer) administered to the patient. The information of the coincidences of the 511 keV photons is used within a reconstruction algorithm to generate an image of the biodistribution of the tracer in the body. The images are usually obtained after the end of the acquisition, but in some cases it would be useful to be able to obtain PET images in real-time. Iterative image reconstruction methods usually provide better resolution and less statistical fluctuations than analytical methods, but they are too slow to be used in real time applications. On the other hand, analytical methods are fast but, they produce images with artifacts when the acquired data are incomplete, they are more sensitive to noise, and their resolution is not optimal as they are based on pure mathematical approaches and assumptions. In this work, we propose to combine the best features of both analytical and iterative methods. We incorporate the most relevant physical processes involved in the emission and detection of the radiation into a System Response Matrix (SRM), and then the reconstruction is obtained using the pseudoinverse (PINV) of the SRM. This method present an improvement in image quality comparing with common real time analytical methods while it is fast enough to be used in real-time applications.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. G.H. Golub, C.F. Van Loan. Matrix Computations

    Google Scholar 

  2. V.V. Selivanov, R. Lecomte, IEEE TNS 2001. https://doi.org/10.1109/23.940160

    Article  ADS  Google Scholar 

  3. J. Sánchez-González, S. España, M. Abella et al., IEEE NSS/MIC (2005)

    Google Scholar 

  4. J.M. Arco, J.M. Udias, J.L. Herraiz, M. Desco, J.L. Longas, R. Matesanz, J.J. Vaquero, WMIC (2015)

    Google Scholar 

  5. F. Noo, M. Defrise, R. Clackdoyle, Phys. Med. Biol. 44, 561 (1999)

    Article  Google Scholar 

  6. J.L. Herraiz, J.J. Vaquero, J.M. Udias, IEEE NSS/MIC (2011)

    Google Scholar 

  7. http://www.sedecal.com/products/superargus-pet-ct/

Download references

Acknowledgements

This work was supported by Comunidad de Madrid (S2013/MIT-3024 TOPUS-CM), Spanish Ministry of Science and Innovation, Spanish Government (FPA2015-65035-P, RTC-2015-3772-1). This is a contribution for the Moncloa Campus of International Excellence. Grupo de Física Nuclear-UCM, Ref.: 910059. This work acknowledges support by EU’s H2020 under MediNet a Networking Activity of ENSAR-2 (grant agreement 654002). J. L. Herraiz is also funded by the EU Cofund Fellowship Marie Curie Actions, 7th Frame Program. P. Galve is supported by a Universidad Complutense de Madrid and Banco Santander predoctoral grant, CT27/16-CT28/16.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. López-Montes .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

López-Montes, A., Galve, P., Udías, J.M., López Herraiz, J. (2019). Real-Time Tomographic Image Reconstruction in PET Using the Pseudoinverse of the System Response Matrix. In: García-Ramos, JE., Andrés, M., Valera, J., Moro, A., Pérez-Bernal, F. (eds) Basic Concepts in Nuclear Physics: Theory, Experiments and Applications. RÁBIDA 2018. Springer Proceedings in Physics, vol 225. Springer, Cham. https://doi.org/10.1007/978-3-030-22204-8_28

Download citation

Publish with us

Policies and ethics