Abstract
Positron emission tomography (PET) is a diagnostic imaging modality in nuclear medicine. The most common radionuclide in PET is 18F fluoro deoxyglucose (FDG). In this study we used the information on radionuclide uptake from PET images and software to make an estimation of effective dose received by patients during 18F-FDG PET examination. We analysed data from 50 patients who performed positron emission tomography—computed tomography (PET-CT) examination. Uptake values were collected in bladder, bones, heart wall, kidneys, liver, brain and remainder. Using a simplified biokinetic model, residence time was calculated and used as an input parameter in OLINDA/EXM® software package. The conversion factor from administered activity to effective dose was found to be \( 0.016\frac{{{\text{mSv}}}}{{{\text{MBq}}}} \), which is only 15% less then value found in literature. The method described in the paper might be suitable in situations when standard calculation models are not adequate.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Adams, M.C., Turkington, T.G., Wilson, J.M., Wong, T.Z.: A systematic review of the factors affecting accuracy of SUV measurements. AJR Am. J. Roentgenol. 195, 310–320 (2010)
Allisy-Roberts, P., Williams, J.: Farr’s Physics for Medical Imaging, 2 edn. Elsevier (2007)
ICRP: ICRP Publication 106: Radiation dose to patients from radiopharmaceuticals. Technical Report, International Commission on Radiological Protection (2007)
ICRP: ICRP Publication 103: Recommendations of the International commission on radiological protection. Technical Report, International Commission on Radiological Protection (2008)
Mart-Climent, J.M., Prieto, E., Morn, V., Sancho, L., Rodrguez-Fraile, M., Arbizu, J., Garca-Velloso, M.J., Richter, J.A.: Effective dose estimation for oncological and neurological PET/CT procedures. EJNMMI Res. 7, 37 (2017)
Stabin, M.G.: Mirdose: personal computer software for internal dose assessment in nuclear medicine. J. Nucl. Med. 37(3), 538 (1996)
Stabin, M.G., Sparks, R.B., Crowe, E.: OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine. J. Nucl. Med, 46(6), 1023 (2005)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Switzerland AG
About this paper
Cite this paper
Beganović, A. et al. (2020). Use of Uptake Values to Estimate the Effective Dose to Patients in Positron Emission Tomography. In: Badnjevic, A., Škrbić, R., Gurbeta Pokvić, L. (eds) CMBEBIH 2019. CMBEBIH 2019. IFMBE Proceedings, vol 73. Springer, Cham. https://doi.org/10.1007/978-3-030-17971-7_20
Download citation
DOI: https://doi.org/10.1007/978-3-030-17971-7_20
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-17970-0
Online ISBN: 978-3-030-17971-7
eBook Packages: EngineeringEngineering (R0)