Skip to main content

Western Blotting Using In-Gel Protein Labeling as a Normalization Control: Advantages of Stain-Free Technology

  • Protocol
  • First Online:
Proteomic Profiling

Part of the book series: Methods in Molecular Biology ((MIMB,volume 2261))

Abstract

Western blotting is one of the most used techniques in research laboratories. It is popular because it is an easy way of semiquantifying protein amounts in different samples. In Western blotting, the most commonly used method for controlling the differences in the amount of protein loaded is to independently quantify housekeeping proteins (typically actin, GAPDH or tubulin). Another less commonly used method is total protein normalization using stains, such as Ponceau S or Coomassie Brilliant Blue, which stains all the proteins on the blots. A less commonly used but powerful total protein staining technique is stain-free normalization. The stain-free technology is able to detect total protein in a large linear dynamic range and has the advantage of allowing protein detection on the gel before transblotting. This chapter discusses the theory, advantages, and method used to do total protein quantification using stain-free gels for normalization of Western blots.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Protocol
USD 49.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 139.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 179.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 249.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Bass JJ, Wilkinson DJ, Rankin D, Phillips BE, Szewczyk NJ, Smith K, Atherton PJ (2017) An overview of technical considerations for Western blotting applications to physiological research. Scand J Med Sci Sports 27(1):4–25. https://doi.org/10.1111/sms.12702

    Article  CAS  PubMed  Google Scholar 

  2. Ghosh R, Gilda JE, Gomes AV (2014) The necessity of and strategies for improving confidence in the accuracy of western blots. Expert Rev Proteomics 11(5):549–560. https://doi.org/10.1586/14789450.2014.939635

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  3. Thellin O, Zorzi W, Lakaye B, De Borman B, Coumans B, Hennen G, Grisar T, Igout A, Heinen E (1999) Housekeeping genes as internal standards: use and limits. J Biotechnol 75(2-3):291–295. https://doi.org/10.1016/s0168-1656(99)00163-7

    Article  CAS  PubMed  Google Scholar 

  4. Hu X, Du S, Yu J, Yang X, Yang C, Zhou D, Wang Q, Qin S, Yan X, He L, Han D, Wan C (2016) Common housekeeping proteins are upregulated in colorectal adenocarcinoma and hepatocellular carcinoma, making the total protein a better "housekeeper". Oncotarget 7(41):66679–66688. https://doi.org/10.18632/oncotarget.11439

    Article  PubMed  PubMed Central  Google Scholar 

  5. Pandey N, Ganapathi M, Kumar K, Dasgupta D, Das Sutar SK, Dash D (2004) Comparative analysis of protein unfoldedness in human housekeeping and non-housekeeping proteins. Bioinformatics 20(17):2904–2910. https://doi.org/10.1093/bioinformatics/bth344

    Article  CAS  PubMed  Google Scholar 

  6. Dittmer A, Dittmer J (2006) Beta-actin is not a reliable loading control in Western blot analysis. Electrophoresis 27(14):2844–2845. https://doi.org/10.1002/elps.200500785

    Article  CAS  PubMed  Google Scholar 

  7. Liu NK, Xu XM (2006) Beta-tubulin is a more suitable internal control than beta-actin in western blot analysis of spinal cord tissues after traumatic injury. J Neurotrauma 23(12):1794–1801. https://doi.org/10.1089/neu.2006.23.1794

    Article  PubMed  Google Scholar 

  8. Lowe DA, Degens H, Chen KD, Alway SE (2000) Glyceraldehyde-3-phosphate dehydrogenase varies with age in glycolytic muscles of rats. J Gerontol A Biol Sci Med Sci 55(3):B160–B164. https://doi.org/10.1093/gerona/55.3.b160

    Article  CAS  PubMed  Google Scholar 

  9. Sander H, Wallace S, Plouse R, Tiwari S, Gomes AV (2019) Ponceau S waste: Ponceau S staining for total protein normalization. Anal Biochem 575:44–53. https://doi.org/10.1016/j.ab.2019.03.010

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  10. Goldman A, Harper S, Speicher DW (2016) Detection of proteins on blot membranes. Curr Protoc Protein Sci 86:10 18 11. https://doi.org/10.1002/cpps.15

    Article  Google Scholar 

  11. Gilda JE, Gomes AV (2013) Stain-free total protein staining is a superior loading control to beta-actin for Western blots. Anal Biochem 440(2):186–188. https://doi.org/10.1016/j.ab.2013.05.027

    Article  CAS  PubMed  Google Scholar 

  12. Dsouza A, Scofield RH (2015) Protein stains to detect antigen on membranes. Methods Mol Biol 1314:33–40. https://doi.org/10.1007/978-1-4939-2718-0_5

    Article  PubMed  Google Scholar 

  13. Yonan CR, Duong PT, Chang FN (2005) High-efficiency staining of proteins on different blot membranes. Anal Biochem 338(1):159–161. https://doi.org/10.1016/j.ab.2004.11.010

    Article  CAS  PubMed  Google Scholar 

  14. Westermeier R (2006) Sensitive, quantitative, and fast modifications for Coomassie blue staining of polyacrylamide gels. Proteomics 6(Suppl 2):61–64. https://doi.org/10.1002/pmic.200690121

    Article  PubMed  Google Scholar 

  15. Rivero-Gutierrez B, Anzola A, Martinez-Augustin O, de Medina FS (2014) Stain-free detection as loading control alternative to Ponceau and housekeeping protein immunodetection in Western blotting. Anal Biochem 467:1–3. https://doi.org/10.1016/j.ab.2014.08.027

    Article  CAS  PubMed  Google Scholar 

  16. Vigelso A, Dybboe R, Hansen CN, Dela F, Helge JW, Guadalupe Grau A (2015) GAPDH and beta-actin protein decreases with aging, making stain-free technology a superior loading control in Western blotting of human skeletal muscle. J Appl Physiol (1985) 118(3):386–394. https://doi.org/10.1152/japplphysiol.00840.2014

    Article  CAS  Google Scholar 

Download references

Acknowledgments

This work was supported by grants from the National Institutes of Health Superfund Research Program (P42 ES004699) and the American Heart Association (16GRNT31350040).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Aldrin V. Gomes .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2021 Springer Science+Business Media, LLC, part of Springer Nature

About this protocol

Check for updates. Verify currency and authenticity via CrossMark

Cite this protocol

Neris, R.L.S., Dobles, A.M.C., Gomes, A.V. (2021). Western Blotting Using In-Gel Protein Labeling as a Normalization Control: Advantages of Stain-Free Technology. In: Posch, A. (eds) Proteomic Profiling. Methods in Molecular Biology, vol 2261. Humana, New York, NY. https://doi.org/10.1007/978-1-0716-1186-9_28

Download citation

  • DOI: https://doi.org/10.1007/978-1-0716-1186-9_28

  • Published:

  • Publisher Name: Humana, New York, NY

  • Print ISBN: 978-1-0716-1185-2

  • Online ISBN: 978-1-0716-1186-9

  • eBook Packages: Springer Protocols

Publish with us

Policies and ethics