A plea for the biopsy marker: how, why and why not clipping after breast biopsy?

  • Review
  • Published:
Breast Cancer Research and Treatment Aims and scope Submit manuscript

Abstract

In the last decade, percutaneous breast biopsies have become a standard for the management of breast diseases. Biopsy clips allow for precise lesion localization, thus minimizing the volume of breast to be resected at the time of surgery. With the development of many imaging techniques (including mammography, sonography, and breast magnetic resonance imaging), one of the challenges of the multidisciplinary became to synthesize all informations obtained from the various imaging procedures. The use of biopsy markers after percutaneous biopsy is one of the keys for optimal patient management, helping the radiologist to deal with multiple lesions, to insure correlation across different imaging modalities and to follow-up benign lesions, helping the oncologist by marking a tumor prior to neoadjuvant chemotherapy, helping the surgeon by facilitating preoperative needle localization, to precisely mark the margins of extensive disease and to guide intraoperative tumor resection, and helping the pathologist to insure the lesion of interest has been removed and to identify the region of interest in a mastectomy specimen. We believe biopsy clip markers should be deployed after all percutaneous interventions and present in this review the arguments to support this statement. Minimal indications for clip deployment will also be detailed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. Brenner RJ (2001) Percutaneous removal of postbiopsy marking clip in the breast using stereotactic technique. Am J Roentgenol 176(2):417–419

    CAS  Google Scholar 

  2. Rosen EL, Vo TT (2001) Metallic clip deployment during stereotactic breast biopsy: retrospective analysis. Radiology 218(2):510–516

    PubMed  CAS  Google Scholar 

  3. Philpotts LE, Lee CH (2002) Clip migration after 11-gauge vacuum-assisted stereotactic biopsy: case report. Radiology 222(3):794–796

    Article  PubMed  Google Scholar 

  4. Whaley DH, Adamczyk DL, Jensen EA (2003) Sonographically guided needle localization after stereotactic breast biopsy. Am J Roentgenol 180(2):352–354

    Google Scholar 

  5. Warren R, Kessar P (2001) A method of coil localization for breast lesions seen only on MRI. Br J Radiol 74(882):548–551

    PubMed  CAS  Google Scholar 

  6. Smith LF, Henry-Tillman R, Rubio IT, Korourian S, Klimberg VS (2001) Intraoperative localization after stereotactic breast biopsy without a needle. Am J Surg 182(6):584–589

    Article  PubMed  CAS  Google Scholar 

  7. Fajardo LL, Bird RE, Herman CR, DeAngelis GA (1998) Placement of endovascular embolization microcoils to localize the site of breast lesions removed at stereotactic core biopsy. Radiology 206(1):275–278

    PubMed  CAS  Google Scholar 

  8. Kaufman CS, Delbecq R, Jacobson L (1998) Excising the reexcision: stereotactic core-needle biopsy decreases need for reexcision of breast cancer. World J Surg 22(10):1023–1027 (discussion 1028)

    Article  PubMed  CAS  Google Scholar 

  9. Rahusen FD, Taets van Amerongen AH, van Diest PJ, Borgstein PJ, Bleichrodt RP, Meijer S (1999) Ultrasound-guided lumpectomy of nonpalpable breast cancers: a feasibility study looking at the accuracy of obtained margins. J Surg Oncol 72(2):72–76

    Article  PubMed  CAS  Google Scholar 

  10. Cangiarella J, Gross J, Symmans WF, Waisman J, Petersen B, D’Angelo D, Singer C, Axelrod D (2000) The incidence of positive margins with breast conserving therapy following mammotome biopsy for microcalcification. J Surg Oncol 74(4):263–266

    Article  PubMed  CAS  Google Scholar 

  11. Nurko J, Mancino AT, Whitacre E, Edwards MJ (2005) Surgical benefits conveyed by biopsy site marking system using ultrasound localization. Am J Surg 190(4):618–622

    Article  PubMed  Google Scholar 

  12. Liberman L (2000) Centennial dissertation. Percutaneous imaging-guided core breast biopsy: state of the art at the millennium. Am J Roentgenol 174(5):1191–1199

    CAS  Google Scholar 

  13. Esserman LE, Cura MA, DaCosta D (2004) Recognizing pitfalls in early and late migration of clip markers after imaging-guided directional vacuum-assisted biopsy. Radiographics 24(1):147–156

    Article  PubMed  Google Scholar 

  14. Phillips SW, Gabriel H, Comstock CE, Venta LA (2000) Sonographically guided metallic clip placement after core needle biopsy of the breast. Am J Roentgenol 175(5):1353–1355

    CAS  Google Scholar 

  15. Burbank F, Forcier N (1997) Tissue marking clip for stereotactic breast biopsy: initial placement accuracy, long-term stability, and usefulness as a guide for wire localization. Radiology 205(2):407–415

    PubMed  CAS  Google Scholar 

  16. Liberman L, Dershaw DD, Morris EA, Abramson AF, Thornton CM, Rosen PP (1997) Clip placement after stereotactic vacuum-assisted breast biopsy. Radiology 205(2):417–422

    PubMed  CAS  Google Scholar 

  17. Liberman L, Gougoutas CA, Zakowski MF, LaTrenta LR, Abramson AF, Morris EA, Dershaw DD (2001) Calcifications highly suggestive of malignancy: comparison of breast biopsy methods. Am J Roentgenol 177(1):165–172

    CAS  Google Scholar 

  18. Guenin MA (2000) Clip placement during sonographically guided large-core breast biopsy for mammographic-sonographic correlation. Am J Roentgenol 175(4):1053–1055

    CAS  Google Scholar 

  19. Meissnitzer M, Dershaw DD, Lee CH, Morris EA (2009) Targeted ultrasound of the breast in women with abnormal MRI findings for whom biopsy has been recommended. Am J Roentgenol 193(4):1025–1029

    Article  Google Scholar 

  20. Dash N, Chafin SH, Johnson RR, Contractor FM (1999) Usefulness of tissue marker clips in patients undergoing neoadjuvant chemotherapy for breast cancer. Am J Roentgenol 173(4):911–917

    CAS  Google Scholar 

  21. Edeiken BS, Fornage BD, Bedi DG, Singletary SE, Ibrahim NK, Strom EA, Holmes F (1999) US-guided implantation of metallic markers for permanent localization of the tumor bed in patients with breast cancer who undergo preoperative chemotherapy. Radiology 213(3):895–900

    PubMed  CAS  Google Scholar 

  22. Baron LF, Baron PL, Ackerman SJ, Durden DD, Pope TL Jr (2000) Sonographically guided clip placement facilitates localization of breast cancer after neoadjuvant chemotherapy. Am J Roentgenol 174(2):539–540

    CAS  Google Scholar 

  23. Uematsu T, Kasami M, Uchida Y, Sanuki J, Kimura K, Tanaka K, Takahashi K (2007) Preoperative computed tomography-guided percutaneous hookwire localization of metallic marker clips in the breast with a radial approach: initial experience. Acta Radiol 48(5):483–487

    Article  PubMed  CAS  Google Scholar 

  24. Eby PR, Calhoun KE, Kurland BF, Demartini WB, Gutierrez RL, Peacock S, Anderson BO, Byrd DR, Mann GN, Lehman CD (2010) Preoperative and intraoperative sonographic visibility of collagen-based breast biopsy marker clips. Acad Radiol 17(3):340–347

    Article  PubMed  Google Scholar 

  25. Gittleman MA (2003) Single-step ultrasound localization of breast lesions and lumpectomy procedure. Am J Surg 186(4):386–390

    Article  PubMed  Google Scholar 

  26. Samimi M, Bonneau C, Lebas P, Michenet P (2009) Mastectomies after vacuum core biopsy procedure for microcalcification clusters: value of clip. Eur J Radiol 69(2):296–299

    Article  PubMed  CAS  Google Scholar 

  27. Curpen NB (1998) Radiologic Society of North America meeting

  28. Uematsu T (2007) Commercially available titanium clip placement following a sonographically guided core needle biopsy of the breast. Breast J 13(6):624–626

    Article  PubMed  Google Scholar 

  29. Margolin FR, Kaufman L, Denny SR, Jacobs RP, Schrumpf JD (2003) Metallic marker placement after stereotactic core biopsy of breast calcifications: comparison of two clips and deployment techniques. Am J Roentgenol 181(6):1685–1690

    Google Scholar 

  30. Margolin FR, Jacobs RP, Denny SR, Schrumpf JD (2003) Clip placement after sonographically guided percutaneous breast biopsy. Breast J 9(3):226–230

    Article  PubMed  Google Scholar 

  31. Ariche-Maman S, Maruani A, Michenet P, Bonneau C, Degand P, Lebas P (2003) Value of ultrasound detection of post-mammotome scar for preoperative localization of breast microcalcifications. J Radiol 84(11 Pt 1):1747–1751

    PubMed  CAS  Google Scholar 

  32. Rosen EL, Baker JA, Soo MS (2003) Accuracy of a collagen-plug biopsy site marking device deployed after stereotactic core needle breast biopsy. Am J Roentgenol 181(5):1295–1299

    Google Scholar 

  33. Lee CH, Singla A, Lee Y (2001) Biomedical applications of collagen. Int J Pharm 221(1–2):1–22

    Article  PubMed  CAS  Google Scholar 

  34. Dotto JE, Lee CH, Tavassoli F (2006) Macroscopic and microscopic images of the collagen-titanium biopsy site marker clip. Int J Surg Pathol 14(1):35–36

    Article  PubMed  Google Scholar 

  35. Tamai K, Mitsumori M, Fujishiro S, Kokubo M, Ooya N, Nagata Y, Sasai K, Hiraoka M, Inamoto T (2001) A case of allergic reaction to surgical metal clips inserted for postoperative boost irradiation in a patient undergoing breast-conserving therapy. Breast Cancer 8(1):90–92

    Article  PubMed  CAS  Google Scholar 

  36. Chaveron C, Bachelle F, Fauquet I, Rocourt N, Faivre-Pierret M, Ceugnart L (2009) Clip migration after stereotactic macrobiopsy and presurgical localization: technical considerations and tricks. J Radiol 90(1 Pt 1):31–36

    Article  PubMed  CAS  Google Scholar 

  37. Lehman CD, Shook JE (2003) Position of clip placement after vacuum-assisted breast biopsy: is a unilateral two-view postbiopsy mammogram necessary? Breast J 9(4):272–276

    Article  PubMed  Google Scholar 

  38. Kruger BM, Burrowes P, MacGregor JH (2002) Accuracy of marker clip placement after mammotome breast biopsy. Can Assoc Radiol J 53(3):137–140

    PubMed  Google Scholar 

  39. Kass R, Kumar G, Klimberg VS, Kass L, Henry-Tillman R, Johnson A, Colvert M, Lane S, Harshfield D, Korourian S et al (2002) Clip migration in stereotactic biopsy. Am J Surg 184(4):325–331

    Article  PubMed  Google Scholar 

  40. Uematsu T, Kasami M, Takahashi K, Watanabe J, Yamasaki S, Tanaka K, Tadokoro Y, Ogiya A (2011) Clip placement after an 11-gauge vacuum-assisted stereotactic breast biopsy: correlation between breast thickness and clip movement. Breast Cancer. doi:10.1007/s12282-011-0252-y

  41. Reynolds HE (1999) Marker clip placement following directional, vacuum-assisted breast biopsy. Am Surg 65(1):59–60

    PubMed  CAS  Google Scholar 

  42. Schulz-Wendtland R, Heywang-Kobrunner SH, Aichinger U, Kramer S, Wenkel E, Bautz W (2002) Do tissue marker clips after sonographically or stereotactically guided breast biopsy improve follow-up of small breast lesions and localisation of breast cancer after chemotherapy? Rofo 174(5):620–624

    Article  PubMed  CAS  Google Scholar 

  43. Burnside ES, Sohlich RE, Sickles EA (2001) Movement of a biopsy-site marker clip after completion of stereotactic directional vacuum-assisted breast biopsy: case report. Radiology 221(2):504–507

    Article  PubMed  CAS  Google Scholar 

  44. Harris AT (2003) Clip migration within 8 days of 11-gauge vacuum-assisted stereotactic breast biopsy: case report. Radiology 228(2):552–554

    Article  PubMed  Google Scholar 

  45. Birdwell RL, Jackman RJ (2003) Clip or marker migration 5–10 weeks after stereotactic 11-gauge vacuum-assisted breast biopsy: report of two cases. Radiology 229(2):541–544

    Article  PubMed  Google Scholar 

  46. Parikh JR (2005) Delayed migration of Gel Mark Ultra clip within 15 days of 11-gauge vacuum-assisted stereotactic breast biopsy. Am J Roentgenol 185(1):203–206

    Google Scholar 

  47. Parikh J (2004) Ultrasound demonstration of clip migration to skin within 6 weeks of 11-gauge vacuum-assisted stereotactic breast biopsy. Breast J 10(6):539–542

    Article  PubMed  Google Scholar 

  48. DiPiro PJ (1999) Disappearance of a localizing clip placed after stereotactic core biopsy of the breast. Am J Roentgenol 173(4):1134

    CAS  Google Scholar 

  49. Perlet C, Sittek H, Reiser M, Heywang-Kobrunner SH (2005) Clip marker placement following MR-guided vacuum biopsy of the breast. Radiologe 45(3):230–236

    Article  PubMed  CAS  Google Scholar 

  50. Lee SG, Piccoli CW, Hughes JS (2001) Displacement of microcalcifications during stereotactic 11-gauge directional vacuum-assisted biopsy with marking clip placement: case report. Radiology 219(2):495–497

    PubMed  CAS  Google Scholar 

  51. Davis PS, Wechsler RJ, Feig SA, March DE (1988) Migration of breast biopsy localization wire. Am J Roentgenol 150(4):787–788

    CAS  Google Scholar 

  52. Owen AW, Kumar EN (1991) Migration of localizing wires used in guided biopsy of the breast. Clin Radiol 43(4):251

    Article  PubMed  CAS  Google Scholar 

  53. Kubota K, Gomi N, Wakita T, Shibuya H, Kakimoto M, Osanai T (2004) Magnetic resonance imaging of the metal clip in a breast: safety and its availability as a negative marker. Breast Cancer 11(1):55–59

    Article  PubMed  Google Scholar 

  54. Shellock FG (1999) Metallic marking clips used after stereotactic breast biopsy: ex vivo testing of ferromagnetism, heating, and artifacts associated with MR imaging. Am J Roentgenol 172(5):1417–1419

    CAS  Google Scholar 

  55. Genson CC, Blane CE, Helvie MA, Waits SA, Chenevert TL (2007) Effects on breast MRI of artifacts caused by metallic tissue marker clips. Am J Roentgenol 188(2):372–376

    Article  Google Scholar 

  56. Ghate SV, Baker JA, Hawkins AD, Soher BJ (2011) Titanium vs carbon coated ceramic breast tissue marker clips: 3T MR susceptibility artifact and local signal disturbance. Acad Radiol 18(6):770–773

    Google Scholar 

  57. Katz JF, Homer MJ, Graham RA, Rothschild JG (2000) Metallic fragments on mammography after intraoperative deployment of radiopaque clips. Am J Roentgenol 175(6):1591–1593

    CAS  Google Scholar 

  58. Trop I, David J, El Khoury M, Gautier N, Gaboury L, Lalonde L (2011) Microcalcifications around a collagen-based breast biopsy marker: complication of biopsy with a percutaneous marking system. Am J Roentgenol 197(2):W353–W357

    Article  Google Scholar 

  59. Guarda LA, Tran TA (2005) The pathology of breast biopsy site marking devices. Am J Surg Pathol 29(6):814–819

    Article  PubMed  Google Scholar 

  60. Gombos EC, Esserman LE, Odzer-Umlas SL, Weisberg S, Poppiti RJ Jr (2005) Collagen plug metallic marker clip: mammographic and histopathologic appearance. Breast J 11(4):292–293

    Article  PubMed  Google Scholar 

  61. Calhoun K, Giuliano A, Brenner RJ (2008) Intraoperative loss of core biopsy clips: clinical implications. Am J Roentgenol 190(3):W196–W200

    Article  Google Scholar 

Download references

Conflict of interest

The authors declare that they have no conflict of interest.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Isabelle Thomassin-Naggara.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Thomassin-Naggara, I., Lalonde, L., David, J. et al. A plea for the biopsy marker: how, why and why not clipping after breast biopsy?. Breast Cancer Res Treat 132, 881–893 (2012). https://doi.org/10.1007/s10549-011-1847-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10549-011-1847-x

Keywords

Navigation